• 제목/요약/키워드: Shear Carrying Capacity

검색결과 176건 처리시간 0.034초

Experimental study on the shear thinning effects of viscosity index improver added lubricant by in-situ optical viscometer

  • Jang, Siyonl
    • Korea-Australia Rheology Journal
    • /
    • 제15권3호
    • /
    • pp.117-124
    • /
    • 2003
  • Elastohydrodynamic lubrication (EHL) film is measured under the condition of viscosity index improver added to base oil. In-situ optical contact method using the interference principle make the measuring resolution of ~5 nm possible and enables the measuring range all over the contact area of up to ~300 $\mu\textrm{m}$ diameter. What is more important to the developed method by the author is that the measurement of EHL film thickness is possible in the range from 100 nm to 2 $\mu\textrm{m}$, which is the regime of worst contact failures in precision machinery. Viscosity index improver (VII) is one of the major additives to the modem multigrade lubricants for the viscosity stability against temperature rise. However, it causes shear thinning effects which make the film thickness lessened very delicately at high shear rate (over $10^5 s^{-1}$) of general EHL contact regime. In order to exactly verify the VIIs performance of viscosity stability at such high shear rate, it is necessary to make the measurement of EHL film thickness down to ~100 nm with fine resolution for the preliminary study of viscosity control. In this work, EHL film thickness of VII added lubricant is measured with the resolution of ~5 nm, which will give very informative design tool for the synthesis of lubricants regarding the matter of load carrying capacity at high shear rate condition.

Experimental study on effect of EBRIG shear strengthening method on the behavior of RC beams

  • Shomali, Amir;Mostofinejad, Davood;Esfahani, Mohammad Reza
    • Advances in concrete construction
    • /
    • 제8권2호
    • /
    • pp.145-154
    • /
    • 2019
  • The present experimental study addresses the structural response of reinforced concrete (RC) beams strengthened in shear. Thirteen RC beams were divided into four different sets to investigate the effect of transverse and longitudinal steel reinforcement ratios, concrete compressive strength change and orientation for installing carbon fiber-reinforced polymer (CFRP) laminates. Then, we employed a shear strengthening solution through externally bonded reinforcement in grooves (EBRIG) and externally bonded reinforcement (EBR) techniques. In this regard, rectangular beams of $200{\times}300{\times}2000mm$ dimensions were subjected to the 4-point static loading condition and their load-displacement curves, load-carrying capacity and ductility changes were compared. The results revealed that using EBRIG method, the gain percentage augmented with the increase in the longitudinal reinforcement ratio. Also, in the RC beams with stirrups, the gain in shear strength decreased as transverse reinforcement ratio increased. The results also revealed that the shear resistance obtained by the experimental tests were in acceptable agreement with the design equations. Besides, the results of this research indicated that using the EBRIG system through vertical grooves in RC beams with and without stirrups caused the energy absorption to increase about 85% and 97%, respectively, relative to the control.

가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구 (A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip)

  • 이상민;박영도
    • 대한금속재료학회지
    • /
    • 제48권1호
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

Improvement, analytical verification and application of RC frame beam-column joint models

  • Fan, Guoxi;Wang, Debin;Jia, Jing
    • Earthquakes and Structures
    • /
    • 제14권3호
    • /
    • pp.273-283
    • /
    • 2018
  • Previous experimental researches indicate that reinforced concrete beam-column joints play an important role in the mechanical properties of moment resisting frame structures, so as to require proper design. In order to get better understanding of the beam-column joint performance, a rational model needs to be developed. Based on the former considerations, two typical models for calculating the shear carrying capacity of the beam-column joint including the inelastic reinforced concrete joint model and the softened strut-and-tie model are selected to be introduced and analyzed. After examining the applicability of two typical models mentioned earlier to interior beam-column joints, several adjustments are made to get better predicting of the test results. For the softened strut-and-tie model, four adjustments including modifications of the depth of the diagonal strut, the inclination angle of diagonal compression strut, the smeared stress of mild steel bars embedded in concrete, as well as the softening coefficient are made. While two adjustments for the inelastic reinforced concrete joint model including modifications of the confinement effect due to the column axial load and the correction coefficient for high concrete are made. It has been proved by test data that predicted results by the improved softened strut-and-tie model or the modified inelastic reinforced concrete joint model are consistent with the test data and conservative. Based on the test results, it is also not difficult to find that the improved beam-column joint model can be used to predict the joint carrying capacity and cracks development with sufficient accuracy.

매입형 합성보의 전단합성거동에 대한 비교분석 (Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams)

  • 신현섭;허병욱;배규웅;김긍환
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.67-79
    • /
    • 2008
  • 본 연구에서는 매입형 합성보에서 전체 보의 휨거동 및 합성면에서의 상대변위(Slip) 등을 분석함으로써 화학적 부착, 부착파괴 후 기계적 맞물림 및 마찰작용, 전단 스터드가 합성보 전체의 강도 및 강성과 합성단면에서의 전단합성거동에 기여하는 정도를 해석해 보고자 한다. 이를 위해 U자형 성형강판을 이용한 합성보 및 CT형강 용접방식 강판성형 합성보에 대해 구조성능 실험과 유한요소해석을 수행하였다. 실험 및 해석결과에 의하면, 전단 스터드의 설치 유무에 따라 매입형 합성보의 극한 모멘트성능 차이는 약 10% 미만을 나타내었다. 이것은 강재 보의 단면형상으로 인한 화학적 및 기계적 부착력이 크기 때문에 이에 의한 합성작용으로도 일정 이상의 모멘트성능 발휘가 가능하여 완전합성상태에 해당하는 소성 모멘트내력과의 차이가 비교적 크지 않으며, 합성율이 증가하는 것에 비해 휨모멘트 내력은 완만하게 증가하기 때문으로 나타났다.

외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과 (Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

철골 프리캐스트 콘크리트 합성보 성능 분석 연구 (Load carrying capacity of Structural Composite Hybrid System (Green Frame))

  • 홍원기;김선국;김승일
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2010
  • An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. The composite beams tested in this study were designed to reduce the depth of the slab and beam. The slabs are constructed on top of the edges of the Structural Composite Hybrid System, instead of on top of the steel flange, decreasing the depth of the beams. When concrete is cast on the metal deck plate located on the edges of the precast concrete, the weight of the concrete slabs and other construction loads must be supported by the contacts between the steel and the precast concrete. This interface must not exhibit bearing failures, shear failures, and failures caused by torque due to the loading of the precast concrete. When the contact area between the concrete and the bottom flange of the steel beam is small, these failures of the concrete are likely and must be prevented. The premature failure of precast concrete must not also be present when the weight of the concrete slabs and other construction loads is loaded. This paper presents a load carrying capacity of Structural Composite Hybrid System in order to observe the failure mode. The symmetrically distributed loading that caused the failure of the composite beam was found. The paper also provides design recommendations of such type of composite structure.

Damage assessment of shear connectors with vibration measurements and power spectral density transmissibility

  • Li, Jun;Hao, Hong;Xia, Yong;Zhu, Hong-Ping
    • Structural Engineering and Mechanics
    • /
    • 제54권2호
    • /
    • pp.257-289
    • /
    • 2015
  • Shear connectors are generally used to link the slab and girders together in slab-on-girder bridge structures. Damage of shear connectors in such structures will result in shear slippage between the slab and girders, which significantly reduces the load-carrying capacity of the bridge. Because shear connectors are buried inside the structure, routine visual inspection is not able to detect conditions of shear connectors. A few methods have been proposed in the literature to detect the condition of shear connectors based on vibration measurements. This paper proposes a different dynamic condition assessment approach to identify the damage of shear connectors in slab-on-girder bridge structures based on power spectral density transmissibility (PSDT). PSDT formulates the relationship between the auto-spectral densities of two responses in the frequency domain. It can be used to identify shear connector conditions with or without reference data of the undamaged structure (or the baseline). Measured impact force and acceleration responses from hammer tests are analyzed to obtain the frequency response functions at sensor locations by experimental modal analysis. PSDT from the slab response to the girder response is derived with the obtained frequency response functions. PSDT vectors in the undamaged and damaged states can be compared to identify the damage of shear connectors. When the baseline is not available, as in most practical cases, PSDT vectors from the measured response at a reference sensor to those of the slab and girder in the damaged state can be used to detect the damage of shear connectors. Numerical and experimental studies on a concrete slab supported by two steel girders are conducted to investigate the accuracy and efficiency of the proposed approach. Identification results demonstrate that damages of shear connectors are identified accurately and efficiently with and without the baseline. The proposed method is also used to evaluate the conditions of shear connectors in a real composite bridge with in-field testing data.

Distribution of shear force in perforated shear connectors

  • Wei, Xing;Shariati, M.;Zandi, Y.;Pei, Shiling;Jin, Zhibin;Gharachurlu, S.;Abdullahi, M.M.;Tahir, M.M.;Khorami, M.
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.389-399
    • /
    • 2018
  • A perforated shear connector group is commonly used to transfer shear in steel-concrete composite structures when the traditional shear stud connection is not strong enough. The multi-hole perforated shear connector demonstrates a more complicated behavior than the single connector. The internal force distribution in a specific multi-hole perforated shear connector group has not been thoroughly studied. This study focuses on the load-carrying capacity and shear force distribution of multi-hole perforated shear connectors in steel-concrete composite structures. ANSYS is used to develop a three-dimensional finite element model to simulate the behavior of multi-hole perforated connectors. Material and geometric nonlinearities are considered in the model to identify the failure modes, ultimate strength, and load-slip behavior of the connection. A three-layer model is introduced and a closed-form solution for the shear force distribution is developed to facilitate design calculations. The shear force distribution curve of the multi-hole shear connector is catenary, and the efficiency coefficient must be considered in different limit states.

강합성 거더용 철근콘크리트 전단연결체의 전단강도 평가 (Estimation of Shear Strength of RC Shear Connection for the Steel-Concrete Composite Girder)

  • 신현섭;유영준;정연주;엄인수
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.229-239
    • /
    • 2010
  • 최근 건설재료의 효율적 활용과 단면구조의 최적화로써 기존 강합성 거더의 구조성능과 시공성을 향상시키고자 새로운 형상의 강합성 거더 및 거더와 바닥판의 전단합성을 위한 RC 전단연결체가 고안된 바 있다. 본 연구에서는 RC 전단연결체의 구조거동 및 전단강도를 평가하였다. 이를 위해 전단철근비를 변수로 하여 Push-out 실험을 실시하였고, 다양한 설계변수에 대한 유한요소해석을 수행하여 그 결과를 분석하였다. 실험 및 유한요소해석 결과에 의하면 RC 전단연결체의 전단강도를 기존 규준식으로 산정할 경우 매우 안전측으로 평가된다. 본 연구에서는 RC 전단연결체의 전단강도를 적절히 산정하기 위해 회귀분석적 방법으로 전단강도 평가식을 제안하였다.