• Title/Summary/Keyword: SharpIR

Search Result 37, Processing Time 0.03 seconds

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

A Study on Characteristics of an IR Sensor with Bluetooth (Bluetooth를 이용한 적외선 센서의 특성에 관한 연구)

  • Park, Sun-Jin;Jeong, Jung-Su
    • Convergence Security Journal
    • /
    • v.6 no.3
    • /
    • pp.79-86
    • /
    • 2006
  • This paper studies the sensitivity analysis of an infrared rays (IR) sensor (SHARP-GD2D12) with bluetooth communication. To evaluate the performance of the IR sensor-bluetooth module, the distance and angle data between the sensor and the fixed object are measured with an IR sensor and the measured data are transferred to PC via bluetooth within 100 meters. This experiment shows that the IR sensor-bluetooth system can be used to measure the distance and angle for a fixed object within 100 meters.

  • PDF

A Study of Heat Transfer in Supersonic Flow Field on a Sharp Fin Shape (Sharp Fin에 의한 초음속 유동장내 열전달 변화 연구)

  • Song, Ji-Woon;Yu, Man-Sun;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.371-374
    • /
    • 2006
  • Heat transfer characteristic near a sharp fin in a supersonic flow was studied. Infra-red thermography was used to obtain the variation of surface heat transfer coefficient distribution. The attack angle of fin is ranged from $10^{\circ}\;to\;20^{\circ}$ and the oil flow method was also conducted to understand a flow field near a sharp fin.

  • PDF

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

FT-IR and X-Ray Diffraction Characterization of Melanoidins Formed from Glucose and Fructose with Amino Acid Enantiomers in the Maillard Reaction

  • Kim, Ji-Sang;Lee, Young-Soon
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.546-551
    • /
    • 2009
  • The objective of this study was to investigate Fourier transform infrared (FT-IR) spectrometry and the X-ray diffraction (XRD) characterization of melanoidins formed from glucose and fructose with amino acid enantiomers in the Maillard reaction. Before dialysis, FT-IR spectroscopy of all the samples showed that the characteristic absorption intensities appeared as a broad and intense band of the stretching vibration of the -OH group at 3,400/cm for a high pH. The absorption bands of the melanoidins sharply decreased in intensity after dialysis as compared to those before dialysis. In particular, the absorption bands at 992 and 575/cm disappeared. The XRD confirmed that the crystal structure of the melanoidins disappeared after dialysis and a new crystal structure was formed at 9 and $28^{\circ}$ ($2{\theta}$. In particular, broad diffraction peaks were formed in the $10-21^{\circ}$ ($2{\theta}$) range for a high pH, while other sharp diffraction peaks disappeared.

High-Resolution Spectroscopy of Hydrogen Emission Lines around a Herbig star, MWC 1080 with IGRINS

  • Kim, Il-Joong;Oh, Heeyoung;Jeong, Woong-Seob;Lee, Jae-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.68.1-68.1
    • /
    • 2019
  • Using IPHAS $H{\alpha}$ data, we found bright $H{\alpha}$ regions inside the elongated $^{13}CO$ cavity around a Herbig star, MWC 1080. To investigate the ionized hydrogen regions and the molecular cavity, we perform near-IR high-resolution spectroscopic of hydrogen Brackett lines and molecular hydrogen lines by Immersion GRating INfrared Spectrograph (IGRINS) observations. We detected broad Brackett line series and sharp molecular lines with various velocity components. We present three ionized hydrogen regions (near MWC 1080A, MWC 1080E, and CO boundary) with different line widths, central radial velocities, and line ratios. We also show two spatially-separate $Br{\gamma}$ ${\lambda}2.1662{\mu}m$ peaks near MWC 1080A. To reveal a 3D structure of the cavity around MWC 1080, we try to use the detected sharp molecular lines.

  • PDF

Study of 68Ga Labelled PET/CT Scan Parameters Optimization (68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구)

  • In Suk Kwak;Hyuk Lee;Si Hwal Kim;Seung Cheol Moon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

Synthesis and Characterization of Phosphorescent Platinum and Iridium Complexes of 6-Chloro-3-phenylpyridazine

  • Lee, Sang-Jin;Seok, Kang;Lee, Jae-Sung;Lee, Seung-Hee;Hwang, Kwang-Jin;Kim, Young-Kwan;Kim, Young-Sik
    • Journal of Photoscience
    • /
    • v.10 no.2
    • /
    • pp.185-187
    • /
    • 2003
  • The preparation and the photophysics of organometallic Pt(II) and Ir(III) complexes with 6-ch1oro-3-phenylpyridazine (H6Clppdz) are reported. $K_2$PtCl$_4$ and IrCl$_3$ㆍn$H_{2}O$ cleanly cyclometalate with H6Clppdz, forming the corresponding chloro-bridged dimers, (6Clppdz)Pt($\mu$-Cl)$_2$Pt(6Clppdz) and (6Clppdz)$_2$Ir($\mu$-Cl)$_2$Ir(6Clppdz)$_2$ in good yield. These chloro-bridged dimers are cleaved with acetylacetone (Hacac) to give the corresponding monomer, (6Clppdz)Pt(acac) and (6Clppdz)$_2$ Ir(acac), respectively. Both complexes show bright orange luminescence at room temperature and the emission wavelengths are different depending on the metal and the structure of complexes. (6Clppdz)Pt(acac) shows two sharp emission bands in shorter wavelength ($\lambda$$_{em}$=541 and 580 nm), while (6Clppdz)$_2$ Ir(acac) shows a broad emission band in longer wavelength ($\lambda$$_{em}$=615 nm). Strong spinorbit coupling due to the heavy metal atom allows for the formally forbidden mixing of the $^1$MLCT with the $^3$MLCT and $^3$$\pi$-$\pi$$^{*}$ states.

  • PDF

Variation of Supersonic Aircraft Skin Temperature under Different Mach number and Structure (비행마하수와 형상에 따른 초음속 항공기 표면온도 변화)

  • Cha, Jong Hyun;Kim, Taehwan;Bae, Ji-Yeul;Kim, Taeil;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.463-470
    • /
    • 2014
  • Stealth technology of combat aircraft is most significant capability in recent air battlefield. As the detector of IR missiles is being developed, IR stealth capability which is evaluated by IR signature level become more important than it was in previous generation. Among IR signature of aircraft from various sources, aerodynamic heating dominates in long-wavelength IR spectrum of $8{\sim}12{\mu}m$. Skin temperature change by aerodynamic heating which is derived by effects of Mach number and structure. The 4th and 5th generation aircraft are selected for calculation of the skin temperature, and its height and velocity in numerical conditions are 10,000 m and Ma 0.9~1.9 respectively. Aircraft skin temperature is calculated by computing convection of fluid and conduction, convection and radiation of surface. As the aircraft accelerates to higher Mach number, maximum skin temperature increases more rapidly than average temperature and temperature distribution changes in more sharp, interactive ways. The 4th generation aircraft whose shape is more complex than that of the 5th generation aircraft have complicated temperature distribution. On the other hand, the 5th generation aircraft whose shape is relatively simple shows plain temperature distribution and lower skin temperature in terms of both average and maximum value.

A Study on the MC-CDMA Using CMFB IIR Filter

  • Shin, Jonghong;Jang, Sunbong;Jee, InnHo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.405-408
    • /
    • 2002
  • Because of superior division among sub-channels, DWT MC-CDMA is less interference with neighborhood channel. In our newly proposed multi-carrier CDMA data transmission method, lIR CMFB filter banks sharply divide sub-bands and reduces spectral overlaps among neighboring sub-channels. In experiment result, proposed filter is better ability of sub-band division than FIR filter. Since the proposed cosine modulated filter banks lIR filter having wavelet property is designed to response sharp transition band, the ISI and ICI between neighboring sub-channels can be effectively reduced. And robustness about narrow band interference of CMFB IIR MC-CDMA almost same FIR DWT MC-CDMA.

  • PDF