• Title/Summary/Keyword: Shaping ability Nickel-titanium rotary file

Search Result 9, Processing Time 0.026 seconds

SHAPING ABILITY OF NICKEL-TITANIUMROTARY FILES (다양한 엔진 구동형 파일의 근관 성형 능력 비교)

  • Park, Wan-Ky;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2004
  • This study compared the shaping ability of nickel-titanium rotary files with different rake angle and radial land. The nickel-titanium files used in this study were Profile(Dentsply, Maillefer, Ballaigues, Switzerland), Hero 642(Micromega, Besancon, France) and K3 (SybronEndo, Glendora, Ca, USA) file. Resin blocks substituted for root canals. 36 resin blocks were divided into 3 groups with 12 canals each The time for canal preparation was recorded. The images of pre- and postoperative resin canal were scanned and those were superimposed Amounts of canal deviation, total canal widths, inner canal widths, and outer canal widths were measured at apical 1, 2 ,3, 4, 5, 6, and 7mm levels. The amount of canal deviation was the smallest in Profile group , and the time far canal preparation was the shortest in Hero 642 group. K3 group resulted in competent characteristics in both measurements. Positive rake angle seemed to result in fast shaping of root canal and radial land guide the instrument in center of the canals and around curvatures. Radial land also tended to reduce the sense of screwing into the root canal. The proper selection of the nickel-titanium fie based on the knowledge about file design is needed for the safer, simpler and faster root canal therapy.

COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS (모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교)

  • Kum, Kee-Yeon;Lim, Kyoung-Ran;Jung, Il-Young;Lee, Sung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

Mechanical and geometric features of endodontic instruments and its clinical effect (근관치료 기구의 기계 형태적 특성과 이에 따른 임상적 영향 고찰)

  • Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Introduction: The aim of this paper is to discuss the mechanical and geometric features of Nickel-titanium (NiTi) rotary files and its clinical effects. NiTi rotary files have been introduced to the markets with their own geometries and claims that they have better ability for the root canal shaping than their competitors. The contents of this paper include the (possible) interrelationship between the geometries of NiTi file (eg. tip, taper, helical angle, etc) and clinical performance of the files as follows; - Fracture modes of NiTi rotary files - Non-cutting guiding tip and glide path - Taper and clinical effects - Cross-sectional area and clinical effects - Heat treatments and surface characteristics - Screw-in effect and preservation of root dentin integrity - Designs for reducing screw-in effect Conclusions: Based on the reviewed contents, clinicians may have an advice to use various brands of NiTi rotary instruments regarding their advantages which would fit for clinical situation.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.

Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems

  • Tufenkci, Pelin;Orhan, Kaan;Celikten, Berkan;Bilecenoglu, Burak;Gur, Gurkan;Sevimay, Semra
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.30.1-30.11
    • /
    • 2020
  • Objectives: This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods: In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results: No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions: These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.