• Title/Summary/Keyword: Shape Dimensional Accuracy

Search Result 296, Processing Time 0.032 seconds

A Study on Cross Sectional Shape Design of Intermediate Pass in the Multi-Stage Shape Drawing (다단 이형인발공정의 중간패스 단면형상 설계에 관한 연구)

  • Lee, J.E.;Lee, T.K.;Lee, S.K.;Kim, S.M.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.4
    • /
    • pp.283-289
    • /
    • 2009
  • The multi-stage shape drawing is used to obtain long shaped products with high levels of dimensional accuracy and quality. It is important to design the cross sectional shapes of the intermediate passes to meet the required dimensional accuracy of the final product in the multi-stage shape drawing. Until now, the cross sectional shapes of the intermediate passes have been designed by the experiences. It is still remained unsolved problem to design the cross sectional shapes of intermediate pass drawing dies in the multi-pass shape drawing. In this study, a new technique is proposed to design the cross sectional shapes of intermediate passes. The proposed method is applied to a multi-stage shape drawing for a LM-guide which is one of the representative shape drawing products. In order to verify the effectiveness of the proposed method, FE-simulation and experiments have been carried out. The dimensional accuracy of the proposed method is compared with that of the conventional shape drawing process designed by the industrial engineers.

Determination of Initial Billet Shape to Improve Dimensional Accuracy in Backward Extruded Cups (후방압출공정에서 치수정밀도 향상을 위한 초기소재형상 결정)

  • Kim, H.C.;Kim, T.H.;Park, J.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 1997
  • Experimental studies have been carried out to obtain uniform cups by one operation of backward extrusion. A lot of factors on dimensional accuracy of backward extruded cups are billet material, billet shape, punch shape, punch velocity, geometry of tool, tool material, and lubrication etc. In manufacturing cup-shaped parts by backward extrusion, it is very important to design the initial billet shape or the preform. The objective of this paper is to find that the shape of the initial billet is related to dimensional accuracy and also to manufacture the more accurate product simultaneously reducing the loss of material as forming the shape of the initial billet by means of upsetting.

  • PDF

Design of Intermediate Die for Spline Drawing (스플라인형상 인발을 위한 중간패스 단면형상 설계)

  • Lee, T.K.;Lee, J.E.;Lee, S.K.;Kim, B.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.337-340
    • /
    • 2008
  • The cross section shape of intermediate die is one of important parameters to obtain dimensional accuracy of final product in shaped drawing process. Until now it has been designed by the experience or trial and error of the expert. In this study, the cross section shape of intermediate die fur spline shape is determined by the electronic field analysis, shape factor method. The result of the electronic field analysis, shape factor method has been compared with that of the present method. The effects of cross section shape on the dimensional accuracy were investigated by using FE analysis. And then the multi-stage shaped drawing experiments were performed to verify the results of FE analysis. As a result, the cross section shape from the electronic field analysis had the good dimensional accuracy. The electronic field analysis can be used for the method to obtain the cross section shape of intermediate die in shaped drawing process.

  • PDF

Design of the Cross Sectional Shape of Intermediate Die for Shaped Drawing of Spline (스플라인 이형인발을 위한 중간 다이 단면형상 설계)

  • Lee, J.E.;Lee, T.K.;Lee, S.K.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.627-632
    • /
    • 2008
  • The cross sectional shape of intermediate die is one of important parameters to improve dimensional accuracy of final product in shaped drawing process. Until now, it has been designed by the experience or trial and error of the expert. In this study, the cross sectional shape of intermediate die for spline shape is determined by the electric fields analysis and scale factor method. The result of the electric fields analysis and scale factor method have been compared with that of the expert method. The effects of cross sectional shape on the dimensional accuracy were investigated by using FE-simulation. And then the multi-stage shaped drawing experiments were performed to verify the results of FE-simulation. As a result, the cross sectional shape from the electric fields analysis and scale factor method had the good dimensional accuracy. These two methods can be used for the method to obtain the cross sectional shape of intermediate die in shaped drawing process.

Process Map for Improving the Dimensional Accuracy in the Multi-Stage Drawing Process of Rectangular Bar with Various Aspect Ratio (다양한 종횡비의 직사각바 다단 인발공정에서 치수정도 향상을 위한 프로세스 맵)

  • Ko, P.S.;Kim, J.H.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.27 no.3
    • /
    • pp.154-159
    • /
    • 2018
  • In the rectangular bar multi-stage drawing process, the cross-section dimensional accuracy of the rectangular bar varies depending on the aspect ratio and process conditions. It is very important to predict the dimensional error of the cross-section occurring in the multi-stage drawing process according to the aspect ratio of the rectangular bar and the half die angle of each pass. In this study, a process map for improving the dimensional accuracy according to the aspect ratio was derived in the drawing process of a rectangular bar. FE-simulation of the multi-stage shape drawing process was carried out with four types of rectangular bar. The results of the FE-simulation were trained to the nonlinear relationship between the shape parameters using an Artificial Neural Network (ANN), and the process maps were derived from them. The optimum half die angles were determined from the process maps on the dimensional accuracy. The validity of the suggested process map for aspect ratios 1.25~2:1 were verified through FE-simulation and experimentation.

Improvement in Dimensional Accuracy of Transfer-type for Variable Lamination Manufacturing using Expandable Polystyrene Foam (VLM-ST의 형상정밀도 향상에 관한 연구)

  • 최홍석;이상호;안동규;양동열;문영복;박두섭;채희창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1047-1050
    • /
    • 1997
  • Rapid Prototyping(RP) is an efficient method for rapid design verification and trial manufacturing. In order to improve their unique characteristics according to the working principles. Variable Lamination Manufacturing process and corresponding CAD/CAM system is developed. The objective of this study is to improve dimensional accuracy of VLM-ST process, and it can be done by offset for cutting error correction, cutting path correction for sharp edge and reference shape generation. To verify the proposed algorithms, they applied to three-dimensional shapes, such as spanner and mechanical part.

  • PDF

A COLD FORGING OF HELICAL GEAR FOR STEERING PINION

  • Kim M.E.;Kim Y.G.;Choi S.;Na K.H.;Lee Y.S.;Lee J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.59-62
    • /
    • 2003
  • The precision cold forging of helical gear for steering pinion has been studied. Because of the large helix angle, there are many difficult problems to control the material flow and part dimension. The die shape was proposed to improve the flow of workpiece. In order to improve the dimensional accuracy of forged part, a FE analysis was performed. The proposed die shape drives to flow amicably workpiece. The applied load was reduced up to 10 percent, compared to the conventional-shaped-die. The elastic deformation of die has been investigated quantitatively by the 3-dimensional FE analysis. The die-land has been expanded up to $10{\mu}m$ on loading stage, based on the FEM results. Therefore, the elastic deformation amounts should be taken into consideration to improve the dimensional accuracy of forged helical gear.

  • PDF

Forging Process Design for Dimensional Accuracy of an Irregular Shape Product (치수 정밀도 향상을 위한 비대칭 정밀제품의 단조공정 설계)

  • 이선홍;최창혁;김성태;김용조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1097-1100
    • /
    • 2004
  • A rear axle spider in an irregular shape, which is used as a part in the braking system of a vehicle like a big truck and a trailer, is subjected to a large torque and hence requires both strength and endurance over the brake heat. This part should be therefore manufactured in dimensional accuracy. The practical manufacturing process of this irregular product requires the heat treatment process after hot forging and then the cold coining process for the dimensional accuracy. At the present study, the warm coning without the heat treatment process was proposed to employ the residual heat due to the hot forging process. And also the trimming and piercing process was designed using the rigid-plastic finite element method. The mechanical properties were discussed and also commented upon.

  • PDF

Shape accuracy and curing characteristics of photopolymer during fabrication of three-dimensional microstructures using microstereolithography (마이크로광조형법을 이용한 미세삼차원구조물의 제조공정 중 형상정밀도 및 경화특성에 관한 연구)

  • Jung, Dae-Jun;Kim, Sung-Hoon;Jeong, Sung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.46-50
    • /
    • 2004
  • The curing characteristics of a liquid photopolymer during microstereolithography and the shape accuracy of thereby fabricated microstructures were investigated experimentally. A He-Cd laser with a wavelength of 442nm and a photopolymer consisted of a commercial resin from SK chemical and a photoinitiat or were used for the experiment. By varying the laser beam power and scanning speed of the focused laser beam, minimum curing thickness of 50 ${\mu}ㅡ$ was obtained. The distortion of solidified structure due to adhesion force was measured and the optimum fabrication conditions were determined. Also, the feasibility of direct fabrication of three-dimensional microstructures by Super IH process was examined.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.