• Title/Summary/Keyword: Shape Correction Factor

Search Result 64, Processing Time 0.028 seconds

The Shape and Virial Theorem of a Star Cluster in the Galactic Tidal Force Field

  • Lee, See-Woo;Rood, Herbert J.
    • Journal of The Korean Astronomical Society
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 1969
  • On the instantaneous tidal relaxation approximation, formulae are derived for the ellipticities and virial theorem of a slightly flattened homogeneous rotating cluster (the largest axis of the cluster is directed towards the Galactic center), in terms of the Galactic tidal force and the characteristic intrinsic plus orbital angular velocity. The expression for a purely tidally-determined ellipticity is identical to that for an incompressible fluid body of uniform density. Orbital motion generally contributes significantly to the shape of the cluster. The virial theorem is identical to that for an isolated cluster except that the gravitational potential energy is multiplied by (1-${\chi}$), where ${\chi}$ is a positive tidal correction term. To obtain the actual mass of a cluster, the virial theorem mass based on an isolated cluster should be multiplied by the factor 1/(1-${\chi}$). The formulae are applied to open star clusters, the globular cluster ${\omega}$ Centauri, and dwarf elliptical galaxies in the Local Group.

  • PDF

Comparative Pattern Analysis and the Fitness Evaluation of Brassieres (국내.외 브래지어의 패턴비교분석 및 착의평가 연구)

  • Suh, Chu-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.4
    • /
    • pp.673-685
    • /
    • 2010
  • This study evaluates the fitness of brassieres through size measurement, comparative pattern analysis, cross section map analysis, 3-D shape analysis number, and fitness evaluation with a focus on domestic and overseas brands. Experimental brassieres were selected as mold brassieres of 3/4 cup in 75A size that is considered a popular design. Brands of selected brassiere were 2 domestic brands (A, B), 1 licensed brand (C), and 2 overseas brands (D, E). Subjects were 8 women in their early 20's. Data were analyzed by descriptive statistics, analysis of variance, reliability analysis, and factor analysis. The results were as follows; the size and pattern of brassieres showed a difference by each brand even though brassieres are the same design. In the wearing effect of brassieres, overseas brand brassieres played a major role in the breast-up effect, but they were not appropriate for the somatotype of Korean women. Domestic brand brassieres showed the volume-up effect, that was confirmed by the increasing bust circumference, bust depth when subjects wore it. In addition, the licensed brand brassieres showed the correction effect of body shape. Therefore, when purchasing a brassiere, the most important condition is to consider the individual characteristics of the somatotype. The results of factor analysis through a functional evaluation show that wearing satisfaction, size satisfaction, and the position of the bust point were important factors for fitness satisfaction and purchase.

Three Dimensional Correction Factors for the Added Mass in the Horizontal Vibration of Ships (선체수평진동(船體水平振動)에 있어서의 부가질량(附加質量) 3차원수정계수(次元修正係數))

  • K.C.,Kim;B.K.,Yoo
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.11 no.1
    • /
    • pp.9-16
    • /
    • 1974
  • To contribute towards more accurate estimation of the virtual inertia coefficient for the horizontal vibration of ships, three dimensional correction factor $J_H$ for the added mass of finitely long elliptic prismatic bars in horizontal vibration in a free surface of an ideal fluid are calculated. In the problem formulation Dr. T. Kumai's quasi-finite length concept[1,11,12] is employed. Now that, in Dr. Kumai's work[1] for the horizontal vibration the mathematical model was a circular cylinder, the principal aim of the authors' work is to investigate the influence of the beam-draft ratio B/T on $J_H$. The numerical results of this work are shown in Fig.3 graphically, from which we may recognize that the influence of B/T on $J_H$ is remarkable as much as that of the length-draft ratio L/T(refer to Fig.1 also). In Fig.3 the curves for B/T=2.00 are of those based on Dr. Kumai's result[1]. On the other hand, the experimental data obtained by Burril et al.[9] for the horizontal vibration of finitely long prismatic bars of various cross-section shapes are compared with the theoretical added mass coefficients defined by combination of the authors' $J_H$ from Fig.3 and two dimensional coefficients $C_H$ obtained by Lewis form approximation for the corresponding sections. They are in reasonable correspondence with each other as shown in Fig.2. Finally, considering that the longitudinal profile of full-form ship's hull is well resembled to that of an elliptic cylinder and that the influences of other factors such as the sectional area coefficient and the shape of section contour itself can be well merged in the two dimensional added mass coefficient, the authors recommend that the data given in Fig.3 may be successfully adopted for the three dimensional correction factor the added mass in the horizontal vibration of hull-form ships.

  • PDF

Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries (핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구)

  • Cheong Seongir;Lee Jaekeun;Chung Dongkyu;Ahn Youngchull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

LED PSU using an Integrated Transformer of New Shape (새로운 형상의 통합변압기적용 LED PSU)

  • Joo, Jong-Seong;Lee, Young-Soo;Heo, Ye-Chang;Kim, Eun-Soo;Hwang, In-Gab
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • In this study, an integrated 2-in-1 transformer for a low-weight and low-cost light-emitting diode lighting power supply is proposed. In the transformer, a power factor correction (PFC) inductor and an LLC resonant transformer are placed and integrated on a single magnetic core. The amount of mutual interference, represented by the coupling coefficient, between magnetic fluxes generated from each magnetic source is minimized by using the new shape core of an integrated 2-in-1 transformer. The design consideration on critical conduction mode PFC converter and LLC resonant converter using the proposed 2-in-1 integrated transformer is described, and the overall performance of the 150 W LED PSU shown through the experiment.

Acoustic and Electrical Analysis of Microspeaker for Mobile Phones (모바일 폰용 마이크로스피커의 음향 및 전기 해석)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.525-536
    • /
    • 2014
  • In this paper, GUI program for microspeaker system simulation program was developed and verified through closed box, vent box and 6th order bandpass enclosure system. By using the pseudo loudspeaker model concept, TS parameters and rear volume of microspeaker were identified. Their suitabilities were proved by comparing test results with simulations of electrical impedance and sound pressure response curves for the three box types; closed box, vent box and 6th order bandpass box. Also, MSSP was found to be effective regardless of the microspeaker's shape, either circular or rectangular shape. MSSP can be used for the microspeaker system simulation, and can give a general prediction of such as; sound pressure level curve, electrical impedance, diaphragm velocity and displacement curve according to multiple design parameters; diaphragm mass, compliance, force factor, front and rear volume, front and rear port's diameter and length.

A Study on the Brassiere Wearing Condition and Satisfaction of Augmentation Mammaplasty Patients (유방 확대 수술 환자의 브래지어 착용실태 및 만족도 조사)

  • Yi, Kyong-Hwa;Nam, Young-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1141-1153
    • /
    • 2017
  • The wearing of the correction bra is very important to stabilize the shape of an implant after breast enlargement surgery; however, the verification of the wearing effect is insufficient. This study surveyed women who experienced breast augmentation surgery, to investigate wearing condition and satisfaction with bras worn immediately after surgery and during the recovery period as well as to collect basic data for the development of an improved patient bra. The study results are as follows. More than half of the respondents stated that they wear a cupless brassiere. As a result of the satisfaction by brassiere types, the cupless bra showed the highest satisfaction. The most important factor in choosing a patient's bra after breast augmentation surgery was the "degree of breast compression". Through the application of the results of this study, the necessity of development of the brassiere for breast enlargement patients with improved function and comfort was understood. It is therefore necessary to improve the function of holding the shape of the breast and applying appropriate pressure as well as designing the ventilated material without skin irritation that is superior to the existing brassieres.

FE modeling for geometrically nonlinear analysis of laminated plates using a new plate theory

  • Bhaskar, Dhiraj P.;Thakur, Ajaykumar G.
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.5
    • /
    • pp.409-426
    • /
    • 2019
  • The aim of the present work is to study the nonlinear behavior of the laminated composite plates under transverse sinusoidal loading using a new inverse trigonometric shear deformation theory, where geometric nonlinearity in the Von-Karman sense is taken into account. In the present theory, in-plane displacements use an inverse trigonometric shape function to account the effect of transverse shear deformation. The theory satisfies the traction free boundary conditions and violates the need of shear correction factor. The governing equations of equilibrium and boundary conditions associated with present theory are obtained by using the principle of minimum potential energy. These governing equations are solved by eight nodded serendipity element having five degree of freedom per node. A square laminated composite plate is considered for the geometrically linear and nonlinear formulation. The numerical results are obtained for central deflections, in-plane stresses and transverse shear stresses. Finite element Codes are developed using MATLAB. The present results are compared with previously published results. It is concluded that the geometrically linear and nonlinear response of laminated composite plates predicted by using the present inverse trigonometric shape function is in excellent agreement with previously published results.

Image processing method of two-phase bubbly flow using ellipse fitting algorithm (최적 타원 생성 알고리즘 기반 2상 기포 유동 영상 처리 기법)

  • Myeong, Jaewon;Cho, Seolhee;Lee, Woonghee;Kim, Sungho;Park, Youngchul;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2021
  • In this study, an image processing method for the measurement of two-phase bubbly flow is developed. Shadowgraphy images obtained by high-speed camera are used for analysis. Some bubbles are generated as single unit and others are overlapped or clustered. Single bubbles can be easily analyzed using parameters such as bubble shape, centroid, and area. But overlapped bubbles are difficult to transform clustered bubbles into segmented bubbles. Several approaches were proposed for the bubble segmentation such as Hough transform, connection point method and watershed. These methods are not enough for bubble segmentation. In order to obtain the size distribution of bubbles, we present a method of splitting overlapping bubbles using watershed and approximating them to ellipse. There is only 5% error difference between manual and automatic analysis. Furthermore, the error can be reduced down to 1.2% when a correction factor is used. The ellipse fitting algorithm developed in this study can be used to measure bubble parameters accurately by reflecting the shape of the bubbles.

Elacstic-\Plastic Limit Load Analysis of Notched Specimen by the Finite Element Method (노치 ( Notch )를 가진 試片의 有限要素法에 의한 彈塑性 極限 荷重解析)

  • Lee, Taik-Soon;Kim, Dong-Sub;Hwang, Pyung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.4
    • /
    • pp.379-385
    • /
    • 1983
  • Many papers have shown limit loads of v-notched tension specimens in plane stress by the elastic-plastic finite element method. But they are always higher than the theoretical maximum loads. The present approach tries to find the reasons and formulates correction factor applicable to any notch shape using virtual work principle with triangular elements. The corrected limit loads are in good agreement with theoretical upper bound solutions and they are little influenced by mesh size and specimen length, which make the computing time save.