• Title/Summary/Keyword: Shallow and Deep Dose

Search Result 12, Processing Time 0.03 seconds

Rice Bran Application under Deep Flooding can Control Weed and Increase Grain Yield in Organic Rice Culture

  • Yan, Yong-Feng;Fu, Jin-Dong;Lee, Byun-Woo
    • Journal of Crop Science and Biotechnology
    • /
    • v.10 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • Rice bran application just after transplanting has been increasingly practiced as an herbicide-substitute for organic rice production in Korea. However, this practice is frequently reported to be unsatisfactory in weed suppression. An experiment with five treatments that combines flooding depth, rice bran application dose, and herbicide treatment was done in the paddy field to evaluate whether rice bran application under deep flooding can lead to a successful weed control in compensation for the single practice of rice bran application. Rice bran was broadcasted on the flood water surface just after deep flooding of 8 to 10cm that was started at seven days after transplanting. In the shallow flooding plot without herbicide six weed species were recorded: Monochoria vaginalis, Echinochloa crus-galli, Ludvigia prostrate, Cyperus amuricus, Aneima keisak, and Bidens tripartite. Among the first four dominant weed species, deep flooding significantly suppressed the occurrence of Echinochloa crus-galli and Cyperus amuricus while did not suppress the occurrence of Monochoria vaginalis and Ludwigia prostrate. On the contrary, rice bran application under deep flooding suppressed significantly Monochoria vaginalis and Ludwigia prostrate while didn't exert an additional suppression of Echinochloa crus-galli and Cyperus amuricus compared to deep flooding alone. Rice bran application and deep flooding suppressed complimentarily all the six weed species to a satisfactory extent except for Monochoria vaginalis of which suppression efficacy was 31.9%. Deep flooding reduced the panicle number substantially by inhibiting the tiller production, increased the spikelet number per panicle slightly, and leaded to a lower rice grain yield compared to shallow flooding with herbicide. Rice bran application under deep flooding mitigated the panicle reduction due to deep flooding, increased the spikelets per panicle significantly, and thus produced even higher grain yield in the rice bran application of 2000kg $ha^{-1}$ as compared to the shallow flooding treatment with herbicide. In conclusion, this practice applying rice bran under deep flooding would be promising to be incorporated as an integral practice for an organic rice farming system.

  • PDF

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

A Review of Radiation Field Characteristics and Field Tests for Estimating on the Extremity Dose under Contact Tasks with Radioactive Materials (방사성물질과 접촉하는 작업의 손·발이 받는 피폭방사선량 평가에 대한 고찰)

  • Kim, Hee-Geun;Kong, Tae-Young;Dong, Kyung-Rae;Choi, Eun-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.123-130
    • /
    • 2017
  • Concerns about high radiation exposure to the hands of radiation workers who may contact with radioactive contamination on surfaces in a nuclear power plant (NPP) had been raised, and the Korean regulatory body required the extremity dose estimation during contact tasks with radioactive materials. Korean NPPs conducted field tests to identify the incident radiation to the hands of radiation workers who may contact with radioactive contamination during maintenance periods. The results showed that the radiation fields for contact tasks are dominated by high energy photons. It was also found that the radiation doses to the hands of radiation workers in Korean NPPs were much less than the annual dose limits for extremities. This approach can be applicable to measure and estimate the extremity dose to the hands of medical workers who handle the radioactive materials in a hospital.

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield (140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가)

  • Kim, Ji-Young;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

Dosimetric Quantities for 300 keV Neutrons (300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.37-43
    • /
    • 1986
  • Dosimetric quantities for 300 keV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ Shallow dose equivalent index $H_{I,s}:2.08{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(0.07):1.7{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ Effective quality factor $\bar{Q}^*(10):12.4$

  • PDF

A Study on the Exposure Dose of Frequent Workers and Radiation Workers in a University Hospital (일개 대학병원의 수시출입자와 방사선작업종사자의 피폭선량에 관한 고찰)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.581-587
    • /
    • 2023
  • In this study, we tried to provide basic data for radiation safety management by comparing and analyzing the exposure doses of radiation workers and frequent workers at C University Hospital in Incheon. From January 2021 to December 2022, surface dose and deep dose were analyzed for 30 radiation workers and 8 frequent workers who worked at C university hospital in Incheon. Radiation workers were targeted at radiation technicians and nurses working in the radiation oncology department and nuclear medicine department, and frequent visitors were targeted at frequent workers who manage and clean facilities in the same radiation management area. In the radiation worker group, 3.1 per 10,000 radiation technologist, 1.2 per 100,000 nurses, and 4.5 per 1,000,000 frequent workers showed the possibility of developing side effects on the lungs. The probability of radiation oncology was 1.1 per 10,000 for radiation technologist and 5.2 per 1,000,000 for nurses, and the probability of radiation technologist in nuclear medicine was 2.9 per 10,000 and for nurses was 7.1 per 1,000,000. It is hoped that this study can be used as basic data in future revisions on frequent workers, and it is considered that it will be used as basic data in the field of obstacles in relation to the stochastic effect of radiation in the future.

A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea (원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Maintenance on the water chamber of steam generator, the change of pressurizer heater, the removal of pressure tube feeder, and so on during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, field tests on extremity dose assessment of radiation workers for contact works with high radiation exposure were conducted during the maintenance periods in Korean pressurized water reactors (PWRs) and pressurized heavy water reactors (PHWRs). In this field test, radiation workers were required to wear additional TLDs on the back and wrist, and an extremity dosimeter on fingers including a main TLD on the chest, while performing maintenance. As a result, it was found that the equivalent dose for fingers was distributed in the fixed range of deep dose and the equivalent dose for wrists.

An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants (원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.176-183
    • /
    • 2009
  • Maintenance on the water chamber of steam generator during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosimeter (TLD) readouts from the application tests of two-dosimeter algorithm to Korean NPPs in 2004. It is regarded that inhomogeneous radiation fields for contact operations in NPPs are dominated by high energy photons. In addition, field tests for workers who participated in maintenance on the steam generator during outage at Ulchin NPPs in 2009 and pressure tube replacement at Wolsong NPPs in 2009 were conducted to analyze radiation fields and to estimate the extremity dose. As a result, radiation fields were dominated by high energy photons.

A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital (일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석)

  • Yang, Nam-Hee;Chung, Woon-Kwan;Dong, Kyung-Rae;Choi, Eun-Jin;Ju, Yong-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

Personnel Dosimetry Performance Test (개인방사선 피폭선량판독 성능시험)

  • Na, Seong-Ho;Han, Seung-Jae;Lee, Dew-Hey;Cho, Dae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.131-138
    • /
    • 1996
  • This paper describes the methods and results of the personnel dosimetry performance tests which were been implemented for the first time in Korea in 1995. Seven categories, except the neutron category prescribed in the ANSI N13.11-1993, were adopted in the test. Fifteen types of dosimeters were participated by fourteen dosimeter processing institutes. A total of 129 dosimeters were selected to test-each type - 15 dosimeters for each of the seven categories and 24 for the controls. A total of 144 radiation categories were employed in the test and a total of 2560 (including 400 controls)dosimeters were submitted-7 categories for each type of the fifteen types dosimeters and 39 categories for the retest. The performance index in each category. sum of the absolute value of the bias and the standard deviation value of the performance quotient. was estimated by the use of delivered and processed dose equivalents according to the standard procedure. The performance in a given category was assessed as acceptable, for the deep and shallow dose equivalents (or the absorbed dose), if the performance index was less than 0.5. The test results showed 54% of the processors passed in the first test, 33% in the retest and 13% in the second retest.

  • PDF