• Title/Summary/Keyword: Shaking-table tests

Search Result 331, Processing Time 0.024 seconds

Analysis of influence factors on the seismic earth pressure acting on gravity walls (중력식 옹벽에 작용하는 배면 동적 토력의 영향 인자 분석)

  • 윤석재;김성렬;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.75-82
    • /
    • 2002
  • The Mononobe-Okabe method is generally used to evaluate the dynamic earth force for the seismic design of retaining walls. However, the Mononobe-Okabe method does not consider the effects of the dynamic interactions between the backfill soil and the wall. In fact, a phase difference exists between the inertia force and the seismic earth pressure. In this study, shaking table tests were peformed on gravity walls retaining dry backfill sand to analyze the influence of several parameters (the unit weight of the wall, the input acceleration and base friction) on the development of the seismic earth pressure. The experiments revealed that the magnitude of the inertia force mobilized during seismic loading affected the seismic earth pressure. The difference in the phase angles between the inertia force and the seismic earth pressure was retained at 180 degrees before the wall failed but its magnitude changed significantly as the wall began to fail.

  • PDF

Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using LRB (Lead Rubber Bearing) (납-고무 베어링(LRB) 면진시스템을 적용한 원전주제어실의 진동대 실험)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.429-436
    • /
    • 2005
  • In this study, we made two types of main control room floor systems (Type I, Type II) and several shaking table tests with and without isolation system were conducted to evaluate floor isolation effectiveness of LRB(Lead Rubber Bearing). Both type showed large difference according to input earthquake signals, but showed little difference according to floor type. It is required to make LRB of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such LRB, it is recommended that consideration should be taken into account when applied to main control room of NPP.

  • PDF

Non-linear Time History Analyses of a Piloti-type Building Structure (필로티형 건물의 비선형 시간이력해석)

  • Lee, Han-Seon;Ko, Dong-Woo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.169-176
    • /
    • 2005
  • Many RC building structures of multiple uses constructed in Korea have the irregularities of torsion and soft story at bottom stories. A typical irregular building was selected as prototype and shaking table tests were performed to investigate the seismic performance of this building. The objective of this study is to evaluate the correlation between the experimental and analytical responses of this irregular building structure subjected to the earthquake excitation by using OpenSees(Open System for Earthquake Engineering Simulation). The results of analyses simulate well the effect of axial forces on the shear force of column and axial deformation. However, some discrepancy between analytical and experimental results in the distribution of shear forces and overturning deformation were observed.

  • PDF

Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using FPS(Friction Pendulum System) (마찰진자베어링(FPS) 면진시스템을 적용한 원전주제어실의 진동대 실험)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.445-452
    • /
    • 2005
  • The seismic characteristics with Friction Pendulum System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate floor isolation effectiveness of Friction Pendulum System. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

Shaking Table Tests of Base-Isolated Steel Frame (지진격리된 철골구조물의 진동대 실험)

  • 윤정방
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.136-143
    • /
    • 1997
  • 본 연구에서는 철골구조물을 대상으로 지진격리(Base-Isolation)를 사용하였을 때의 진동감소 효과를 분석하기 위하여 지진하중에 대한 진동대 실험을 수행하였다. 실험 대상구조물은 $\frac{1}{4}$축소모형의 3층 철골구조물이며, 입력지진은 여러 계측기록과 UBC 설계스펙트럼으로부터 3가지 지반조건에 대하여 작성한 인공지진기록을 사용하였다. 축소 실험모형은 기초가 고정된 일반적인 철골구조물과 적층고무받침(Laminated Rubber Bearing) 형식의 지진격리장치(Base Isolator)를 사용한 구조물을 동시에 설치하여 그 지진응답을 비교 관찰하였다. 대부분의 하중하에서 지진격리장치가 사용된 철골구조물의 경우에 지진응답이 현저히 감소하는 것을 알 수 있으나, 장주기파의 성분이 강한 지반운동에 대해서는 오히려 지진응답이 증가하였다. 그러나 여러 지반조건에 대하여 UBC 시방서에서 규정한 설계하중에 대하여는 진동감소효과가 우수함을 보인다.

  • PDF

Application of structural health monitoring in civil infrastructure

  • Feng, M.Q.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.469-482
    • /
    • 2009
  • The emerging sensor-based structural health monitoring (SHM) technology has a potential for cost-effective maintenance of aging civil infrastructure systems. The author proposes to integrate continuous and global monitoring using on-structure sensors with targeted local non-destructive evaluation (NDE). Significant technical challenges arise, however, from the lack of cost-effective sensors for monitoring spatially large structures, as well as reliable methods for interpreting sensor data into structural health conditions. This paper reviews recent efforts and advances made in addressing these challenges, with example sensor hardware and health monitoring software developed in the author's research center. The hardware includes a novel fiber optic accelerometer, a vision-based displacement sensor, a distributed strain sensor, and a microwave imaging NDE device. The health monitoring software includes a number of system identification methods such as the neural networks, extended Kalman filter, and nonlinear damping identificaiton based on structural dynamic response measurement. These methods have been experimentally validated through seismic shaking table tests of a realistic bridge model and tested in a number of instrumented bridges and buildings.

Physical Modeling of Geotechnical Systems using Centrifuge

  • Kim, Dong-Soo;Kim, Nam-Ryong;Choo, Yun-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.194-205
    • /
    • 2009
  • In geotechnical engineering, the mechanical characteristics of soil, the main material of geotechnical engineering, is highly related to the confining stress. Reduced-scale physical modeling is often conducted to evaluate the performance or to verify the behavior of the geotechnical systems. However, reduced-scale physical modeling cannot replicate the behavior of the full-scale prototype because the reduced-scale causes difference of self weight stress level. Geotechnical centrifuges are commonly used for physical model tests to compensate the model for the stress level. Physical modeling techniques using centrifuge are widely adopted in most of geotechnical engineering fields these days due to its various advantages. In this paper, fundamentals of geotechnical centrifuge modeling and its application area are explained. State-of-the-art geotechnical centrifuge equipment is also described as an example of KOCED geotechnical centrifuge facility at KAIST.

  • PDF

SEISMIC STABILITY OF SATURATED REINFORCED SOIL WALLS

  • Kuwano, Jiro;Izawa, Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.66-71
    • /
    • 2010
  • This paper studies the effect of saturation of backfill on the seismic stability of reinforced soil walls (RSWs) using centrifuge shaking table tests. For comparison, degradation of static stability and seismic stability of a RSW under unsaturated condition was also investigated. Test results showed that the RSW under saturated condition had enough static stability. However, seismic stability of saturated RSW significantly decreased as compared with that under unsaturated condition. The saturated model RSW did not collapse, though it showed large deformation. It maintained sufficient stability after shakings although a clear slip surface appeared in the backfill. Finally, it is discussed how to evaluate residual stability of RSWs damaged by earthquakes with test results and the simple evaluation method proposed by authors.

  • PDF

Seismic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탐 실물 크기 모델의 지진시험)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.388-395
    • /
    • 1999
  • There occurred a moderate size earthquake of M=5 at Whagae-Myun Hadong-Gun Kyongsangnam-Do of Korea, It caused severe damage to the buildings and other structures is Sang-Gye-Sa a famous and beautiful Buddhist Temple, The 5-story stone pagoda was standing in front of Keumdang. The top component tipped over and fell to the ground during the earthquake. In order to have accurate and quantitative estimate of the intensity of earthquake a full-scale replica is made through rigorous verification process, The completed model was mounted on the shaking table and subjected to th seismic tests. It was observed that the top component overturned at 0.16 G of EPGA when the NS component of the 1940 el Centro earthquake records was used as the input motion. A brief history of this project is presented and important test results are report6ed and their implication is discussed.

  • PDF

Experimental Study on the Seismic Structural Responses Subjected to Different Earthquakes (지진특성에 따른 구조물의 지진응답실험)

  • 최인길;김형규;김민규;전영선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.82-89
    • /
    • 2003
  • Near-field ground motions exhibit special characteristics that are different from ordinary far-field ground motions. In this study the shaking table tests were conducted to evaluate the effect of earthquake ground motions with different characteristics on the response of the structure. The ground motions used in this study were the scenario earthquake, design earthquake, and Chi-Chi earthquake measured in TCU052 station. These earthquakes have different frequency contents. The test results show that the frequency content of ground motion is very important to the response of structures. The floor responses of structure were greatly affected by the higher modal frequencies, as well as the fundamental frequency. The responses of third floor were significantly reduced due to the interaction between the structure and the base isolated mass installed at the third floor.

  • PDF