• 제목/요약/키워드: Shaft power measurement

검색결과 60건 처리시간 0.024초

베어링 재설계에 의한 원전 COP motor의 진동 제어 (Vibration Control of Condensate Motors in Nuclear Powerplant By Bearing Redesign)

  • 임도형;김원현;이종문;이수목
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the summary of control of abnormal vibration found in the COP motors of a nuclear power plant. All six identical units of COP pump-motor assemblies showed unstable vibration pattern of which one or two showed higher vibration enough to exceed the allowable level from the installation stage. Many trials of test, measurement, overhaul and replacement had been repeated to investigate and solve the problem but only to reach unsatisfactory settlement. Recently several times of site tests are made and followed by significant diagnostic actions in which the authors group participated. It was found that the coupled shafting system of motor and pump is in close resonance with the $1^{st}$ shaft rotating speed. Redesign of topside motor bearing clearance is made to increase bearing stiffness and hence to avoid the resonance which consequently led to reduce the troubled vibration to allowable and stable status.

  • PDF

와전류 동력계에서 계자전류를 이용한 부하토크의 측정에 관한 연구 (A Study on the Measurement of Load Torque by the Field Coil Current in an Eddy Current Dynamometer)

  • 문병수;이응석;이형석
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.84-92
    • /
    • 2001
  • Commercial eddy current dynamometers control the torque of rotating body, power supply machine, with the field coil current being operated as a braking force. In this paper, we studied the relation between field coil current and torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer it is linear relation between the brake force measured from a torque meter which is installed at the case of dynamometer and the multiplied shaft rpm by the squares of field coil current (N$\times$I$^2$). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of the eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measure the torque of rotating body without a torque measuring device. such as load cell.

  • PDF

FFT analysis of load data during field operations using a 75-kW agricultural tractor

  • Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Lee, Dae-Hyun;Choi, Chang-Hyun;Lee, Kyeong-Hwan
    • 농업과학연구
    • /
    • 제40권1호
    • /
    • pp.53-59
    • /
    • 2013
  • Analysis of load data during field operations is highly important for optimum design of power drive lines for agricultural tractor. Objective of the paper was to analyze field load data using FFT to determine frequency and the energy levels of meaningful cyclic patterns. Rotary tillage, plowing, baling, and wrapping operations were selected as major field operations of agricultural tractor. An agricultural tractor with power measurement system was used. The tractor was equipped with strain-gauge sensors to measure torque of four driving axles and a PTO axle, speed sensors to measure rotational speed of the driving axles and an engine shaft, pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to calculate power requirement. In rotary tillage, calculated frequency was decreased as travel speed increased. In baler operation, calculated frequency was increased as PTO speed was increased. The calculated peak frequency levels and expected levels were similar. Results of the study would provide information on power utilization patterns and on better design of power drive lines.

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

소규모 발전용 스크롤 팽창기 성능시험 (Performance Test of Scroll Expander for Micro-Power Generation)

  • 김현진;박익서;라필찬
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.325-332
    • /
    • 2005
  • This paper addresses the development of a scroll expander for power generation from relatively low temperature steam source. It has a double-sided orbiting scroll member so that no thrust bearing is needed to support the base plate of the orbiting scroll. Three power transmission shafts are placed at the periphery of the orbiting scroll base plate, and these shafts can also function as anti-rotation devices. Final output is obtained from the main central shaft engaged with the three power transmission shafts through gear assembly. The clearance between the fixed and orbiting scroll elements was estimated by comparing measurement of the mass flow rate with calculation results of a computer simulation. Due to large clearance, the expander total and volumetric efficiencies were measured to be $34\%\;and\;43\%$, respectively. It has been shown through the computer simulation that the total and volumetric efficiencies could be improved to $65\%\;and\;83\%$, respectively, if the current clearance is reduced by half.

Implementation of Power Line MODEM for TDC Pulse Detection of SEPA

  • Yang, Hyun-Suk;Lee, Byung-Yong;Kim, Yoon-Sik;Seo, Dong-Hoan;Kim, Sung-Hwan;Kwon, Yeong-Gwal;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.430-436
    • /
    • 2008
  • Recently, there are many cases to use a ship's engine performance analyzer(SEPA) to measure pressure in cylinder and top dead center(TDC) of piston of engine, and analyze its performance such as fuel injection time and horsepower as well as wear of piston ring. But, SEPA needs TDC pulses($T(1){\sim}T(n)$) generated when pistons of engine are located to the TDC position ($TDC(1){\sim}TDC(n)$), these pulses are gathered from sensors connected to gear wheel of the propeller shaft in the remote distance from the measurement point. Therefore, operators need a long wire cable(WRC) to TDC detecting sensor to get these pulses, but this method is a very uncomfortable and expensive in case of installation, and it might decrease user's purchase desire. In this paper, we design and fabricate a small and inexpensive MODEM cable(M0C) so that it may be available to transmit TDC pulse generated from sensor in propeller shaft through existing power line. We also verify the facts that this MOC can be applied to SEPA and the effectiveness of the system through the experiments.

고속열차용 전기기계식 제동장치의 동력전달 기구물에 대한 구조해석 (Structural Analysis of Power Transmission Mechanism of Electro-Mechanical Brake Device for High Speed Train)

  • 오혁근;백승구;전창성
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.237-246
    • /
    • 2019
  • 전기기계식 제동장치(EMB : Electro Mechanical Brake)는 자동차 및 철도차량의 차세대 제동장치로서 현재 연구가 활발히 진행되고 있다. 현재의 고속열차용 제동장치는 공압 실린더를 이용하여 제동 압부력을 발생시키나 전기기계식 제동장치 (EMB)에서는 전기 모터 및 기어와의 조합을 통하여 압부력을 발생시킨다. 본 연구에서는 고압부력 발생이 가능한 EMB 구동 메커니즘을 제안하고, 해당 메커니즘을 만드는 기구장치 중 핵심부품인 기어 및 샤프트 부품들에 대한 구조 및 진동해석을 수행하였다. 한편 모델에 대한 동적 진동해석 결과 압부력이 가해진 상태에서 외부가진이 주어졌을 때 부재의 최대 응력이 항복강도 이내임이 확인되었다. 또한, 구조해석 결과 모터샤프트의 축 직경을 최대한 크게하는 설계가 강도 상 유리함을 확인하였으며, 기어와 편심샤프트를 고정하는 볼트에서 큰 전단응력이 발생할 수 있음을 확인하였다. 한편 해석모델의 메커니즘을 재현할 수 있는 시험장치를 제작하여 가장 취약한 부위인 고정 볼트부의 변형률을 구동 토크가 가해진 상태에서 측정하였다. 변형률 측정결과는 해석결과와 오차가 10% 이내로서, 해석모델의 정확도를 검증할 수 있었다.

Analysis of the PTO Torque of a Transplanter by Planting Condition

  • Kim, Wan Soo;Chung, Sun Ok;Choi, Chang Hyun;Cho, Jong Seung;Choi, Dug Soon;Kim, Young Joo;Lee, Sang Dae;Hong, Soon Jung;Kim, Yong Joo;Koo, Seung Mo
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.313-318
    • /
    • 2016
  • Purpose: This study measured and analyzed the PTO (power take off) torque of a transplanter according to the planting conditions during field operation. Methods: A torque measurement system was constructed with torque sensors to measure the torque of a PTO shaft, a measurement device to acquire sensor signals, and a power controller to provide power for a laptop computer. The field operation was conducted at four planting distances (26, 35, 43, and 80 cm) and two planting depths using the transplanter on a field with similar soil conditions. One-way ANOVA with planting distance and Duncan's multiple range test at a significance level of 0.05 were used to analyze the PTO torque. The torque ratio was calculated based on the minimum torque using the average PTO torque measured under each planting condition. Results: The average torques on the PTO shaft for planting distances of 26, 35, 43, and 80 cm at a low planting depth were 11.05, 9.07, 7.04, and 3.75 Nm, respectively; the same for planting distances of 26, 35, 43, and 80 cm at a middle planting depth were 12.20, 9.86, 7.94, and 4.32 Nm, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at a low planting depth increased by 88, 142, and 195%, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at the middle planting depth increased by 84, 128, and 182%, respectively. Conclusions: PTO torque fluctuated by planting distance and depth. Moreover, the PTO torque increased for short planting distances. Therefore, farmers should determine the planting conditions of the transplanter by considering the load and durability of the machine. The results of this study provide useful information pertaining to the optimum PTO design of the transplanter considering the field load.

유체커플링의 토오크 특성과 효율에 관한 실험적 연구 (An Experimental Study on Torque Characteristics and Efficiency of Hydraulic Couplings)

  • 박용호;염만오
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.46-55
    • /
    • 1994
  • The purpose of this research is to construct experimental test set-up and to establish a series of performance test program for the domestically developed hydraulic couplings, and to provide a software to store and utilize these experimental data which can be used to improve the performance of the hydraulic coupling and solve the job problems confronted during operation. The performance test consists of measurement of torque, rpm and efficiency of the hydraulic coupling for three different amounts of working fluid with various loads to the output shaft, and investigating the torque, rpm and efficiency characteristics with respect to these parameters. The results of this study can contribute to the development of variable speed hydraulic coupling and torque converter pursued by the domestic industry.

  • PDF

브레이크 부하를 이용한 유체커플링 실험장치 개발과 토크 성능 예측 (The Development of Hydraulic-Coupling Experimental Apparatus Using Brake Load and Prediction of Torque Performance)

  • 박용호;김기홍
    • 한국정밀공학회지
    • /
    • 제17권5호
    • /
    • pp.100-107
    • /
    • 2000
  • The hydraulic couplings have been widely used in industries, automobile, and power-station drives including ships. A mathematical analysis by which the design and application of hydraulic couplings are made is used in conventional design formulae and general roto-dynamic theories. The fluid flow of hydraulic couplings can be considered to have two component, one circumferentially about the coupling axis, and the other passing fluid from the pump to the turbine in the plane of the coupling axis. Tests have been carried out on the full-scale production coupling. The performance test consists of taking measurement of torque of the fluid coupling for three different amount of working fluid inside with various loads to the output shaft. The purpose of this research is to construct the experimental test equipments and to establish a series of performance test for the domestically developed hydraulic couplings, and to obtain experimental results which can be used to improve the performance of the hydraulic coupling and to solve the practical problems confronted in operation.

  • PDF