• 제목/요약/키워드: Shade matching

검색결과 32건 처리시간 0.038초

자연치와 도재관에 대한 색조선택의 동일성 (Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가 (THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY)

  • 김이경;조인호;신수연
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

Effects of eye dominance on shade matching and color perception among the dentist population

  • Pattnaik Kalyani;Kannan Subiksha;Amit Jena;Govind Shashirekha;Saumyakanta Mohanty;Gaurav Sharma
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.40.1-40.8
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of eye dominance on color perception, and shade matching. Materials and Methods: A total of 104 participants were selected for the study. There were 3 groups: Group I: 3rd and 4th year dental students and interns (n = 40); Group II: postgraduates (n = 34); Group III: senior residents and faculty members (≥ 6 years of clinical experience) (n = 30). All participants were evaluated for congenital color blindness with Ishihara plates, their dominant eye with Mile's test, and their color perception with the Farnsworth-Munsell 100 hue test. The shade guide test was used for shade matching with a second corresponding set of Vitapan classical shade guides. Results: The results of Mile's test revealed that 60.6% were right-eye dominant and 39.4% were left-eye dominant. There was a statistically significant difference among all participants between the dominant eye and the non-dominant eye in shade matching. Conclusions: The dominant eye has a positive effect on shade matching and the ability to match shades becomes better with an increase in clinical experience.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

광원(光源), 배경색(背景色), 소요시간(所要時間)이 치아색(齒牙色) 선택(選擇) 능력(能力)에 미치는 영향(影響) (A CORRELATIVE STUDY OF THE EFFECTS OF LIGHT SOURCE, BACKGROUND COLOR, AND TIME SPENT ON THE ABILITY TO MATCH TOOTH SHADE)

  • 권오임
    • 대한치과보철학회지
    • /
    • 제16권1호
    • /
    • pp.38-44
    • /
    • 1978
  • Color is an important factor in dental esthetics. Application of natural tooth color will not fail to produce pleasing results. But a standardized method of shade matching has not been adopted. If we are to overcome the color matching problem in dentistry, an understanding of the nature of color and light is essential. The purpose of this study was to compare the effects of different light sources and different background colors on the ability of observers to correctly match shades of artifical teeth. And observation was made to determine if the time spent in making a shade match was a factor in the correctness of the response. A test method was devised and 50 individuals made observations which were recorded and analyzed. $X^2$-test gave results indicating that the time factor had no effect on the response made. An analysis of variance showed the following effects significant at the five percent level; (1) light source (2) background color (3) subject. The following conclusions can be drawn from this study; (1) The time spent in making shade selection is not a factor in the correctness of the selections. (2) The light source used is an important factor in matching tooth shade; and there is no significant difference between the light sources in shade matching. (3) Under the conditions of this study, the greatest accuracy in shade matching was obtained on the brown background.

  • PDF

Color Matching of Single-Shade Composite Resin by Various Pulp Capping Materials in Anterior Teeth

  • Sohyun Park;Jongsoo Kim;Jongbin Kim;Mi Ran Han;Jisun Shin;Joonhaeng Lee
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.176-184
    • /
    • 2024
  • This study aimed to compare color matching between single-shade composite resin-restored teeth with various pulp capping materials and the dentin surrounding the restoration through instrumental analysis and visual evaluation of the color difference. Fifty maxillary right central incisor acrylic resin teeth were prepared with standardized Class III cavities on the proximal surfaces. These teeth were divided into five groups: restored with single-shade composite resin only; Ultra-BlendTM plus followed by single-shade composite resin; TheraCal PTTM followed by single-shade composite resin; Endocem® MTA premixed followed by single-shade composite resin; and Well-root PTTM followed by single-shade composite resin. The color difference (ΔEab*) between the restored area and the center of the resin teeth was measured using a spectrophotometer. No significant color difference was observed in groups restored with only single-shade composite resin, Ultra-BlendTM plus, and TheraCal PTTM. The visual evaluation revealed that Ultra-BlendTM plus exhibited the best color matching score, whereas the Endocem® MTA premixed and Well-root PTTM groups showed significantly lower color matching scores than the single-shade composite resin-only group. When opting for single-shade composite resin usage for anterior tooth restorations with the aim of reducing chair time, pulp capping materials Ultra-BlendTM plus and TheraCal PTTM provide esthetically pleasing results.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Porcelain 제작시 고려 사항 (Considerations in Porcelain Fused Metal Restorations)

  • 김진완
    • 대한심미치과학회지
    • /
    • 제8권1호
    • /
    • pp.90-95
    • /
    • 1999
  • Although various kinds of porcelain restorations, including full porcelain jacked crowns and laminate crowns, are used for Esthetic Dentistry nowadays, the most widely used one so far is porcelain metal restoration. It goes without saying that shade matching in porcelain-metal restoration is much more difficult than in full ceramic veneer restoration because of the metal substructure limitation of the porcelain to metal restoration and then let it go even when shade matching is a little bit unsatisfactory. I think a more satisfactory shade matching can be achieved by developing more elaborate techniques, by selecting proper metal and porcelain and by enabling more detailed communication between the dentists and the dental technicians. Some considerations will be made in an attempt to achieve more successful outputs.

  • PDF

색조 선택 시스템을 이용한 shade guide의 색조 분석 (Evaluation of shade guide using digital shade analysis system)

  • 이승택;이종혁;신수연
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.1-11
    • /
    • 2009
  • 연구목적: 심미 수복을 위한 색상 결정 방법으로는 색견본 (shade guide)과 치아를 눈으로 직접 비교하는 기존의 비색법과 최근 소개되기 시작한 색상 측정용 기기를 사용하는 방법이 있다. 비색법은 치과의사들과 기공사들 간의 색조 선택에 일관성이 결여되어 있는 등 많은 문제점이 지적되고 있지만 아직도 이러한 방법에 의한 색상 결정과 결정 색상에 대한 표현 방식이 임상 치의학에 적용되고 있다. 본 연구의 목적은 진료실과 기공소에서 사용하고 있는 색견본이 같은 값을 가지는지 ShadeEye - $NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan)로 확인하고 또한 이 측정 기기의 두 가지 모드가 동일한 shade tab을 같은 값으로 인식하는지 확인하고자 하였다. 연구재료 및 방법: 첫 번째 실험에서는 모두 8개의 Vita Lumin Vacuum shade guide (Vident Inc., California, USA)를 모아 그 중 A1과 B1 shade tab을 각각 5회씩 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 하였고 두 번째 실험에서는 치과 진료실과 기공소에서 실제 사용하고 있는 Vita Lumin Vacuum shade guide를 각각 12개씩 모아 역시 A1과 B1 shade tab을 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 실시하였다. 결과: 첫 실험에서 8개의 색견본의 A1과 B1의 5회씩 측정에서 두 가지 mode에서 모두 채도 (shade), 명도 (value), 색상 (hue)에서 유의한 차이를 보였다(P<.05). 두 번째 실험에서는 진료실에서 사용하는 색견본과 기공소에서 사용하는 색견본 사이에는 통계적으로 유의한 차이를 보이지 않았으나, A1의 porcelain mode 에서 채도가 유의한 차이를 보여 (P<.05), 같은 shade tab이라 할지라도 채도에서 차이가 날 수 있음을 보였다. 결론: ShadeEye-$NCC^{(R)}$의 mode에 따라 동일한shade tab을 다른 값으로 인식하는 것으로 나타나 진료실과 기공소 간에 동일한 mode로 사용하는 것이 필요할 것으로 사료된다.