• Title/Summary/Keyword: Shade guide

Search Result 52, Processing Time 0.039 seconds

INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING (Shade guide의 형태가 색상 결정에 미치는 영향)

  • Park, Geol;Kim, Dong-Jun;Lee, Shee-Eun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.170-177
    • /
    • 2005
  • This study was conducted in order to assess whether the form of the shade guide affects in deciding the color of the teeth using the shade guide Eight shade light cured composite resins (Esthet-X, Dentsply, Milford, USA) were used in this study. Shade guides including the model of maxillary central incisors, teeth-form shade guide, doughnut form shade guide, and shade guide with perforated gray shield were prepared with eight shade composite resins and provided the codes randomly After arranging the models of teeth, 19 dentists working at the clinic of the Dentistry of Chonnam University Hospital and 65 students of college of dentistry, Chonnnam University selected the shade guides corresponding to the color of each tooth on the gray board under the D$_{65}$ standard illuminant. Bl shade showed highest accuracy of about 95% among all shade guides of 3 forms applied to the test and regardless of observer, tooth form shade guide showed the highest accuracy (p < 0.05) , and the doughnut form showed the lowest accuracy (p < 0.05). At the time of deciding on the color of the teeth using the shade guides as a result of above, the forms of the shade guides can affect the accuracy, and it suggests that the development of the diversified forms of shade guides, which may obtain more accurate results, is required.

A Study on Color Differences Between Composite Resins and Shade Guides (복합레진과 shade guide의 색차에 관한 연구)

  • Kim, Hee-Sun;Um, Chung-Moon;Kahng, Myong-Whai
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.107-120
    • /
    • 1996
  • 복합레진은 조작이 용이하고 강도가 우수하며 중합시간이 짧고 법랑질과 상아질에 접착이 가능하며 연마성이 뛰어나고 자연스러운 색상을 나타내므로 심미적 수복에 가장 일반적으로 선택되는 재료의 하나이다. 대부분의 복합레진 kit에는 shade guide가 포함되어 있어 이를 기준으로 중합된 후의 복합레진 색조를 예상하여 선택하게 된다. 그러나 이러한 shade guide들은 대개 복합레진이 아닌 plastic으로 제조된 것으로 중합된 복합레진의 실제 색조와는 차이가 생기게 되며 결국 shade guide 자체의 문제점으로 인해 이상적인 색조선택이 어려워진다. 이에 본 연구에서는 국내에 시판되고 있는 5종의 복합레진 제품을 선정하여 분광 광도계를 이용해서 shade guide와 중합된 복합레진 사이의 색조차이를 측정, 비교 연구하였다. 직경 16mm. 두께 1.6mm의 plastic mold에 5종의 광중합형 복합레진(Z100, Prisma TPH, Tetric, Silux Plus, Herculite XR)을 충전하고 응축기에 넣어 압축한 후 제조사의 지시에 따라 광중합기로 중합시킨 후 mold에서 시편을 제거하여 보관했다가 젖은 sandpaper 상에서 순차적으로 연마하였다. shade guide는 step부분을 갈아내어 복합레진 시편과 동일한 두께로 만든후 연마하였다. 분광광도계에 shade guide를 넣고 CIE illuminant D65 하에서 spectral reflectance를 측정하고 해당 색조의 복합레진 시편도 통일한 방법으로 측정하고 $L^*$, $a^*$, $b^*$값과 ${\Delta}E^*$값을 얻은후 분석하여 다음과 같은 결과를 얻었다. 1. Z100의 D3, A3, B2 shade와 Prisma TPH의 B2 shade를 제외한 모든 시편에서 shade guide와 복합레진간에 육안으로 인지할 수 있는 색차(${\Delta}E^*$ > 1.0)가 관찰되었다. 2. 평균적으로 Z100이 가장 적은 색차를 나타내었고 Prisma TPH, Tetric, Silux Plus, Herculite XR 순으로 색차가 증가하였다. 3. Prisma TPH의 A2 shade. Tetric의 W shade. Silux Plus의 YB, U shade, Herculite XR의 L, LY shade는 ${\Delta}E^*$값이 3.3 이상으로 나타났다. 4. Z100, Prisma TPH, Tetric, Silux Plus에서는 복합레진보다 shade guide가 더 높은 $L^*$값을 보이는 경향이 나타났으며, Herculite XR에서만 복합레진이 더 높은 $L^*$값을 나타냈다. 5. 모든 시편에서 $b^*$ 값은 (+)로 관찰되었고, Z100, Prisma TPH, Tetric, Silux Plus의 shade guide는 복합레진에 비해 높은 $b^*$값을 보였다. 6. 모든 시편에서 $a^*$값은 (-)로 관찰되었고. Herculite XR 및 Silux Plus에서는 복합레진이 shade guide 에 비 해 낮은 $a^*$값을 나타냈다.

  • PDF

THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY (수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가)

  • Kim Lee-Kyoung;Cho In-Ho;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES (가시광선영역에서 shade guide에 따른 광투과도 특성 연구)

  • Choi, Keun-Bae;Park, Charn-Woon;Song, Chang-Yong;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Proposal for a gingival shade guide based on in vivo spectrophotometric measurements

  • Polo, Cristina Gomez;Montero, Javier;Casado, Ana Maria Martin
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.239-246
    • /
    • 2019
  • PURPOSE. The purpose of this study was to propose and assess a shade guide for pink gingival aesthetics using a Spanish population sample. MATERIALS AND METHODS. The $L^*$, $C^*$, h, $a^*$ and $b^*$ coordinates of 259 participants were measured using a spectrophotometer in 3 standardized points along the attached gingiva of the maxillary central incisors. A hierarchical clustering analysis was applied to obtain separate solutions regarding the number of shade tabs. For each of the solutions obtained, color differences (${\Delta}E^*$) were calculated using the CIELab and CIEDE2000 formulas, and the proposed shade guide was selected considering (1) the color differences between tabs and (2) the coverage error of each of the solutions. RESULTS. The proposed shade guide consisted of 8 gingival shade tabs and achieved CIELab and CIEDE2000 coverage errors of less than the respective 50:50% acceptability thresholds (${\Delta}E^*=4.6$ units and ${\Delta}E_{00}=4.1$). The coordinates for the various gingival shade tabs were as follows: Tab 1: $L^*43.3$, $a^*21.9$, $b^*12.3$ (1.6); Tab 2: $L^*42.9$, $a^*34.1$, $b^*19.1$; Tab 3: $L^*46.5$, $a^*25.8$, $b^*10.9$; Tab 4: $L^*46.5$, $a^*27.3$, $b^*15.1$; Tab 5: $L^*49.6$, $a^*23.5$, $b^*16.8$; Tab 6: $L^*51.5$, $a^*19.7$, $b^*13.6$; Tab 7: $L^*55.9$, $a^*22.0$, $b^*15.0$; and Tab 8: $L^*56.0$, $a^*19.9$, $b^*18.8$. CONCLUSION. The CIELab and CIEDE2000 coverage errors for the 8 shade tabs of the proposed gingival shade guide were significantly lower than those of other guides. Therefore, despite the limitations of this study, the proposed guide is more appropriate for matching gingival shade in the Spanish general population.

Spectrophotometric evaluation of restorative composite shades and their match with a classical shade guide

  • Rafael Melara;Luciana Mendonca;Fabio Herrmann Coelho-de-Souza;Juliana Nunes Rolla;Luciano de Souza Goncalves
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.60.1-60.8
    • /
    • 2021
  • Objectives: The aim of this study was to verify the match between 5 shades of composites from different manufacturers with a shade guide and among the systems using a portable spectrophotometer. Materials and Methods: Shade measurements were performed on specimens of Z350 XT (3M ESPE), Charisma Diamond (Heraeus Kulzer GmbH), Esthet X-HD (Dentsply Caulk), and Empress Direct (Ivoclar-Vivadent) for shades A1, A2, A3, B1, and C3 using a Vita Easyshade spectrophotometer (Vita Zahnfabrik) against a white background. Corresponding shades of Vitapan Classical (Vita Zahnfabrik) guide were measured likewise and shade variation (ΔE) was calculated based on International Commission on Illumination L*a*b* parameters. The ΔE of the composites in each shade was compared by one-way analysis of variance and Tukey's post hoc test (α = 0.05). Results: All composites presented ΔE > 3.7 compared with the shade guide. Variation in shades A3, B1, and C3 was significantly different for all composites. ΔE of Z350 XT was significantly lower for A1 than for the other shades, whereas ΔE of Z350 XT and Charisma Diamond were significantly lower for A2 than for the other shades. Conclusions: No composite shade matched with the shade guide. Equivalent shades of the restorative composite from different manufacturers may show clinically noticeable ΔE.

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

Clinical Color Match using ShadepilotTM (ShadepilotTM을 이용한 색조 선택)

  • Shin, Soo-yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.