• 제목/요약/키워드: Sewers

검색결과 94건 처리시간 0.025초

Effect of Stormwater Runoff on Combined Sewer Overflows in Korea

  • Kim, Lee-Hyung;Kim, Il-Kyu;Lee, Young-Sin;Lim, Kyeong-Ho
    • 한국방재학회 논문집
    • /
    • 제7권4호
    • /
    • pp.107-113
    • /
    • 2007
  • The Kuem-River, one of the largest rivers in Korea, is the primary water source for more than 4 million people in Kongju city and surrounding area. To study the effect of stormwater runoff to CSOs, twelve monitoring sites were selected in two large cities (City of Kongju and City of Buyeo) near the Kuem-River. Monitoring was reformed by collecting grab samples, measuring flow rates during dry and wet seasons during over two rainy seasons. Generally the flow rate of wastewater in combined sewers was rapidly decreased after 23:00 P.M. and gradually increased from 06:30 A.M. in all sites during the dry season. The concentrations of pollutant increase approximately 5 to 7 fold for TSS and 1.5 to 2.5 fold for BOD during the rainy season. Monitoring and statistical analysis show that the groundwater contributes on sewage volume increase (average 25-45% more) during dry periods and the stormwater runoff contributes approximately 51-72% increase during rainy periods. Generally the concentrations of combined sewage were more polluted during the first flush period than after the first flush during a storm event.

퍼지제어를 이용한 양액 자동공급 시스템 개발 (Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • 제23권4호
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

지중매설 경질폴리염화비닐관의 구조적 거동 (Characteristics of Structural Behavior of Unplasticized Polyvinyl Chloride (PVC-U) Pipe Buried Underground)

  • 김선희;천진욱;김응호
    • 복합신소재구조학회 논문집
    • /
    • 제6권4호
    • /
    • pp.16-23
    • /
    • 2015
  • The industrialization and urbanization forced to increase the density of pipelines such as water supply, sewers, and gas pipelines. The materials used for the existing pipe lines are mostly composed of concretes and steels, but it is true that the development for more durable and efficient materials has been continued performed to produce long lasting pipe lines. Recently, underground pipes serve in diverse applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. In this paper, we present the result of investigation pertaining to the structural behavior of unplasticized polyvinyl chloride (PVC-U) flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, pipe stiffness, 4-point bending test, experimental and analytical studies are conducted. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is about 8% although there are significant variations in the mechanical properties of the pipe material. In addition, it was found by the 4-point bending test there is no problem in the connection between the pipes by coupler.

Derivation of Threshold Values for Groundwater in Romania, in order to Distinguish Point & Diffuse Pollution from Natural Background Levels

  • Radu, E.;Balaet, Ruxandra;Vliegenthart, F.;Schipper, P.
    • Environmental Engineering Research
    • /
    • 제15권2호
    • /
    • pp.85-91
    • /
    • 2010
  • Romania aims to adopt and implement the European Union's legislation, also including that for the field of water management. Like other countries, groundwater in Romania is locally polluted from point sources, such as leaking landfills, as well as from diffuse pollution sources, include fertilizers, pesticides and leakages from sewers, in urbanized areas. Diffuse pollution can also occur indirectly, by over-exploitation of groundwater wells, resulting in salt water intrusion, as well as from mining and exploitation of mineral aggregates. Romania has quite an intensive monitoring scheme to measure groundwater quality in phreatic and confined aquifers. The purpose of the work resumed in this paper was to derive natural background levels (NBL) for groundwater in order to distinguish the natural elevated concentrations of some substances (natural phenomena) from point and diffuse pollution (anthropogenic phenomena). Based on these NBLs, threshold values (TV) for groundwater will be set according to the requirements of the European Water Framework Directive and the related Groundwater Directive. This paper describes the results of a study for the derivation of NBL and TV in a pilot Groundwater Body. Also, the process and draft results for extrapolating this work for all Romanian groundwater bodies is explained, as well as points for future consideration with respect to monitoring and management.

기상조건이 하수발생량 및 하수처리장 운전인자에 미치는 영향에 관한 통계적 분석 (Study on the Relationship between Weather Conditions, Sewage and Operational Variables of WWTPs using Multivariate Statistical Methods)

  • 이재현
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.285-291
    • /
    • 2012
  • Generally, the rainfall and the influent of wastewater treatment plants (WWTPs) have strong relationship at the case of combined sewers. With the fact that the influent variations in terms of quantity and sewage quality is the most common and significant disturbance, the impact factor to the characteristics of sewage should be searched for. In this paper, the relationship between weather conditions such as humidity, temperature and rainfall and influent flowrate and contaminant concentration was analysed using factor analysis. Additionally, 3 influent types were deduced using cluster analysis and the distributions of operational variables were compared to the each groups by one-way ANOVA. The applied dataset were clustered to three groups that have the similar weather and influent conditions. These different conditions can cause the different operating conditions at WWTPs. That is, the Group 1 is for the condition with high humidity and rainfall, so DO concentration in the reactor was very high but MLSS concentration was very low because of too large flowrate. However, the Group 3 is classified to the case having low humidity, temperature, and rainfall, therefore, the SRT was the longest and the SVI was the highest due to the worst settleability in the winter for a year.

하수관거시설의 침수대응 운영·관리 실태 연구 (II) (Survey on sewerage operation/management planning for flooding (II))

  • 류재나;차영주;오재일;현인환;김영란;장대환
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.271-276
    • /
    • 2009
  • Under current design standard, sewers are designed to drain stormwater generated up to 10 year return period of storms. This implies sewer flooding could occur from rainfall exceeding a 10 year return period. 5, 10, 20 and 30 year return period of storm intensities were calculated for 22 locations (cities) of meterological stations over the nation and compared to the recorded rainfall intensities for the last 30 years. The comparison resulted in the numbers of year maximum rainfall intensities exceeded each return period. Using the questionnaire survey for "the incidences of flooding since 1980" of the previous paper (Survey on sewerage operation/management planning for flooding (I)), the actual rainfall records on the date of flooding events were analyzed to demonstrate the number of flooding events caused by the exceedance of sewer capacity. For the last 30 years, more than 6 years of year maximum rainfall intensity (20%) were larger than the 10 year return period of storm in 4 cities of the 22 used for the first analysis. The number of rainfall records that exceeded the 10 year return period was 50 of the 260 actual flooding events investigated from the survey.

수산정보 활용방안에 관한 연구 - 통영지역을 중심으로- (A Study on an Utilization Method of Marine Information - on the basic of the Area, Tong-Yeong -)

  • 박연식;이상욱;김영수;정근회;임재홍
    • 한국정보통신학회논문지
    • /
    • 제1권1호
    • /
    • pp.3-12
    • /
    • 1997
  • 본 연구에서는 어업, 양식업, 수산물 유통, 수산 관계 기관을 대상으로 통영 지역에서 많이 생산되고 취급되어지는 수산물 분포 및 유통을 통한 주요 수산업의 동향을 파악하여, 생산자들과 수요자들에게 필요한 정보를 신속하고 실용성 있게 제공할 수 있는 방법으로 인터넷 환경하에서의 수산물 직거래 유통 시스템의 구성 모델을 제시하였다 데이터 베이스 시스템은 분산처리 형태로 구성하였으며, 지역 정보 센타의 서버는 각각의 서버들이 감당하기 곤란한 기능들을 상호 보완하여 운용 가능한 방안을 제시하였다.

  • PDF

우리나라 적합 하수도시설 및 관리방안 (Appropriate Sewerage Systems for Korea)

  • 이상은
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.37-52
    • /
    • 1992
  • Since the first sewage treatment plant was constructed in 1976, the sewerage systems of Korea have been rapidly expanded. As of the end of 1991, 22 sewage treatment plants with total capacity of 5.4 million tons/day are in operation which is equivalent of 3395 total daily sewage generation. Total extension of sewer 39.534 km in 1990 which is 55% of the target extension for the year 2001. However, the most sewage treatment plants employ activated sludge process which may not be suitable for medium and/or small scale plants. The poor existing sewer systems do not effectively collect and transport sewage to adversely affect the function of sewage treatment plant. To select the appropriate treatment system, the cities are classified into 3 categories such as large and medium size inland cities, small size cities and coastal cities. Considering the criteria suggested during this study, appropriate treatment processes were selected for each category. Conventional activated sludge process and step aeration process were found to be the most appropriate for big inland cities while biological nutrient removal processes should be considered for the cities discharge the effluent to lakes or reservoirs. RBC or Oxidation Ditch process might be appropriate for the medium size cities while several processes which do not require skilled operation and maintenance were suggested for the small cities. Ocean discharge after primary treatment can be considered for some east coast cities, Appropriate methodology to rehabilitate the existing sewers and strategy to convert combined sewer system to separate sewer system were proposed. This paper also include the appropriate management system for industrial wastewater, sludge and nightsoil.

  • PDF

개발도상국 중국의 하수처리장 운영.관리능 평가 (O&M Evaluating for Sewage Treatment Plants in China as a Developing Country)

  • 김연권;문용택;김홍석;김지연
    • 환경위생공학
    • /
    • 제21권3호
    • /
    • pp.27-36
    • /
    • 2006
  • For the last 20 years, China has transformed itself from a rural economy into an industrial giant, averaging over 8 % annual growth of GDP. Unfortunately, this rapid growth has taken a significant toll on its natural resource base as well, particularly water resources. These problems have been exacerbated by a low level of sewage treatment technology and by the operating and maintenance (O&M). In case of urban areas, most big cities in China have a well functioning sewage system comprised of sewers and sewage treatment plants (STPs). Nevertheless, the existing STPs are still not capable of properly treating the sewage, both quantitatively and qualitatively. The rural areas in China cover a large land, with two-third of the nation's population. The low educational and poor economic states make it hard to process self-protection and management. In the surveyed area in Henan, there was no STPs put into use as of 2004, and the sewer lines are not well organized. The big issue for the currently planned STPs is the collection system not included in the plans.

효율적 빗물관리를 위한 하수도 요금체계 개편 방안 (The improvement of sewerage fee imposition system for efficient rainwater management)

  • 박규홍;강병준;박주양;박완규;김성태
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.517-527
    • /
    • 2014
  • As sewer flooding frequents due to localized and concentrated stormwater and increased non-permeable surface area after urbanization, building cities with sound water recycle and accordingly efficient management of rainwater is demanded. To do this, the existing sewage (including rainwater) fee imposition system should be philosophically evaluated. This study presents problematic issues of the existing domestic sewage fee imposition system considering the principle of sharing costs on the service of sewage and rainwater collection and treatment. Four methods to improve the existing sewage fee imposition system are suggested: 1) imposing stormwater fee according to Polluter Pays Principle, 2) clarification of the share of public sector, 3) reducing or exempting the sewerage fee for inhabitants reducing urban runoff by constructing their own rainwater management facilities, 4) imposing charge for discharging rainwater to sewers due to new development action. Short, mid, or long term planning for rainwater management is recommended considering the situation of each municipality.