A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province (경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안)

  • Moon, Chul-Hwan;Ahn, Ji-Hoon;Jang, Mi-Jeong;Lee, Sang-Hyup;Cho, Young-Moo;Kim, Yun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.563-580
    • /
    • 2010
  • In 2009 the Korea Ministry of Environment announced 'A Comprehensive Plan for the Improvement of Sewer Service in Rural Area' aiming at reduction of the sewer service gap between urban and rural areas as well as improvement in the residential environment of the rural area. According to the plan, the sewer system supply rate for the rural area is expected to reach up to 75% until 2015 with the budget of 4.7 trillion won (Korean currency). It is not certain, however, that the increase in the sewer system supply rate will accompany improvement of water quality in receiving water because several veiled problems that can occur in small-scale sewer treatment plants are poorly addressed in the plan. In this study, those issues for the small-scale sewer treatment plants and their solutions were discussed based on a case study in which we investigated 19 treatment facilities at two rural regions in Gyeonggi province. This study also included strategies useful for the plan. From the results of investigation, some problems, e.g., high hourly variations but low in flowrates and low mass loading were commonly identified. Although operation parameters in sewer treatment plants require to be modified depending on the mass loading, most of the plants were operated with the initial design parameters which causes the decrease of removal efficiency. In the intensive diagnosis, we arranged and applied solutions (e.g., flow equalization, air on/off time control, etc) to the two selected plants and found out improvement of effluent water quality, especially organic matters (COD and SS) and T-N with better denitrification performance.

A Study on the Seismic Response Formula for Improvement of Seismic Design Code of Water Treatment Underground Structures (수처리 지중구조물의 내진설계 기준 개선을 위한 지진 응답 제안식의 관한 연구)

  • Lee, Joung-Bae;Bae, Sang-Soo;Chung, Kwang-Mo;Bang, Myung-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.41-48
    • /
    • 2022
  • Generally it was known that member forces in the earthquake resistant design is lower than those in the general design. But it is not true in cases of water treatment underground structures, which is different in each case like water treatment plant, sedimentation basin, and utility-pipe conduit. Also, looking at the scale of earthquakes that have recently occurred in Korea, large-scale earthquakes are frequent, so when the magnitude of the design seismic force increases, it is necessary to investigate the seismic behavior of the water treatment underground structure and to deal with it. In this study the change rate of member forces was investigated by the change of design load factor (earthquake acceleration design criteria), earth depth, underground water level. The pseudo-static analysis and response displacement method was applied, and various analyzes were conducted depending on the ground water and soil depth. The proposed formula in this study will be efficient when the earthquake design code of water treatment underground structures is revised.

A study on the analysis of performance differences according to the operation method of public sewage treatment facility (공공하수처리시설 운영방식에 따른 성과 차이 분석에 관한 연구)

  • Ko, Hyunsoo;Ha, Donggyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.357-370
    • /
    • 2022
  • This study aims to analyze the differences in performance according to various operation methods (direct management, public consignment, and private agency) of public sewage treatment facilities and derive the most efficient and high level of sewage treatment services to the public based on the research results. To this end, economic performance indicators (sewage treatment cost, sewerage rate) and social performance indicators (water quality, number of civil complaints) were selected, and cross-sectional analysis and longitudinal analysis were used to verify the difference between the averages of three or more groups through one-way ANOVA. As a result of the analysis, cross-sectional analysis, there was no difference in economic performance dimension according to the operating method, but in terms of social performance dimension, it was found that there was a difference according to the operating method. In the case of water quality indicators, the results were superior to those directly managed by public consignment and private agencies in the number of civil complaints. In the longitudinal analysis examining the improvement of performance indicators, there was no significant difference by operation method in most performance indicators. In order to improve the efficiency of public services and improve the service level, various approaches suitable for the characteristics of each service are required in addition to the logic of public consignment or introduction of private agency. In the future, when local governments promote public consignment or private agency, it is necessary to understand and promote the nature of the service, the specificity of each local government, and the needs of service users.

Study on Local Wireless Network Data Structure for Sludge Multimeter (슬러지 멀티미터를 위한 근거리무선네트워크 데이터구조 설계 연구)

  • Jung, Soonho;Kim, Younggi;Lee, Sijin;Lee, Sunghwa;Park, Taejun;Byun, Doogyoon;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.96-100
    • /
    • 2014
  • Recently, the management system of wastewater treatment facility has magnified due to the stringent regulations for the protection of the environment, and a sewage treatment plant efficiency and research of the car development are activated in large facilities or industrial park. however, the existing sewerage disposal system and specific water quality monitoring network reliability for real-time transmission of this building is insufficient. In this paper, we proposed a local wireless network design for sludge multi meter data collection and control for measuring the concentration of the sludge efficiently. Also, the collected data over the local wireless network to transmitted to the central monitoring system and accumulate the data in real time to calculate statistics is possible to monitor the status of the sewage treatment facilities. The proposed system uses a short-range wireless networks of IEEE 802.15.4 and configures an IEEE 802.11 network which can monitor real-time status in central system. Also, we install a sludge multimeter and communication network in sewage treatment facilities and confirm the usefulness of the proposed technique by demonstrating its effectiveness.

The Effect of Sewer Pipe Retrofit on The Operation of Sewage Treatment Plant in Rural Area (농촌 지역의 하수관거 정비사업이 하수처리장 운영에 미치는 영향)

  • Kim, Seongjung;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • Recently, rural areas are rapidly developing, while existing infrastructure is inadequate and aging compared to developing rural areas. The most representative of these is the sewer system. Therefore, in this study, the rural area of Gyeonggi A city was selected as the study area and analyzed the effect of the sewer maintenance business on the operation of the sewage treatment plant. The analysis items were pollutant treatment efficiencies, the changes of inflow sewage amount, sewage concentration, influnet load, and C / N ratio by comparing before and after the development. As a result of the analysis, the sewage amount increased significantly after the development, and the sewage concentration increased after the development and the load of the sewage in the wastewater treatment plant also increased after the development. And improvement and management of inflow of unidentified water such as infiltration water and influent water in the sewage pipe was improved due to improvement of sewage pipe, which is considered to have affected the increase of C / N ratio and the improvement of TN and TP removal efficiency. The results of this study can be used as a representative example of the sewerage maintenance project in the rural area that positively influenced the operation of the sewage.

Analysis of Seasonal Water Pollution According to the Reuse and Treatment of Wastewater from Anyang Stream (안양천 하수처리 재이용에 따른 계절별 수질오염 분석)

  • Lee, Yang-Kyu;Hong, Chang-Sun;Lim, Kwang-Su
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.2
    • /
    • pp.41-52
    • /
    • 2013
  • Anyang Stream Restoration Movement was started from 2001 for the construction of ecological city. The facilities for reuse of treated sewerage have been used since 2003 for improvement of water quality, maintenance of water quantity, river ecological restoration, and hydrophilic space. Thus, the Anyang city has been gradually transformed to eco-friendly city after the construction of Anyang stream and Hakui stream as natural rivers. In this study, biological and chemical methods as well as ecological indicators for Anyang mainstream and major tributaries were monitored for four years in between 2008 and 2012. The water quality and the diversity of species in most of the streams were found to be good except Anyang main stream. It appears that the influence of seasonal drying stream is almost disappeared except Sammak stream. Thus, the values for BOD (Biochemical Oxygen Demand) and BIP (Biological Index of Pollution) for Anyang main stream were found to be 5.27~3.42mg/l and 4.51~5.50, respectively. This is considered to be caused by the reused water quality of treated wastewater being exceeded the design criteria or by the non-point source of contaminants around the stream. However, entire section of tributaries shows I, II grade as a good water quality.

Analysis of Biotope Area Ratio in the Environmental Impact Statements (환경영향평가서에 나타난 개발사업의 생태면적률 검토 연구)

  • Lee, Sang-Don
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.4
    • /
    • pp.394-401
    • /
    • 2018
  • Tendency in ratio of biotope area of environmental impact assessment (EIA) according to population, location, project type, and total project area was analyzed by type of the projects. According to EIA, biotope area ratio is the ratio of the weighted biotope areas and total project area. biotope area is important to resident's health and quality of their life. Ministry of Environment recommends to meet the biotope area ratio standard presented by each project type. The analysis is based on 4 types of project, urban development, industrial comlpex deveopment, tourism development, and waste and sewerage treatment facility, and 55 data extracted from them. It is needed that new standard that the population is reflected, adjustment that region and frequency are considered, and regulation strengthening according to achievement of 'the minimum achievable goals' to improve biotope area policy. The research includes more data and improvements of specific system are needed as a further research.

A fundamental study on the sulphate-resistant mortar using waste glass fine powder and meta-kaolin according to various fine aggregates (잔골재 종류에 따른 폐유리 미분말 및 메타카올린을 사용한 내황산염 모르타르에 관한 기초적 연구)

  • Jeong, Dongwhan;Park, Junhui;Ahn, Taeho;Park, Yeongsik;Sho, Kwangho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The degradation of the concrete due to deterioration factors, such as corrosion of steel bars, cracks and structural strength of reinforced concrete structures, is a social problem. Especially, concrete structures constructed in seawater, underground water, waste water treatment facilities and sewerage are subject to chemical attack by acid and sulphate. Therefore, this study was conducted to compare sulfated glass and fine aggregate of slag using waste glass fine powder and meta kaolin. The results showed that the slag fine aggregate showed better sulfate resistance than the river sand, and the fine powder of waste glass showed the best performance at 3 % displacement.

The Evaluation of Effect Indicators on Estimation of Aeration Volume for Wastewater Treatment Plants (하수처리장 송풍량 산정에 미치는 영향 인자들의 평가)

  • Kim, Byoung Soo;Choi, Mi Young;Kwon, Hyuck;Kim, Jin Man;Cha, Woon Ou;Chun, Wan Myung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • To construct the system controlling the aeration volume for D wastewater treatment plant effectively, the fluctuation of aeration volume was analyzed with changes of factors of the influent. As a result, the range of aeration volume was wide to maintain the certain concentration of DO, and the key factor to decide the aeration volume was found to be the temperature, F/M ratio, the loading rate of $BOD_5$ and T-N of the influent. Among the factors, the temperature of the influent had the most decisive effect on the aeration volume. The result showed that $45.8m^3/h$ of the aeration volume was needed with an increase of $1^{\circ}C$ of the influent, and the effect of the season was considered. Since the temperature of the influent is affected by a change of season, same as F/M ratio, the loading rate of the influent and the concentration of MLSS, it seemed that the change of the temperature of the influent affects the aeration volume even more. Therefore, it is preferable to consider the loading rate of the influent and F/M ratio altogether, rather than considering only one factor when deciding aeration volume.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.