• 제목/요약/키워드: Sewer flow

검색결과 197건 처리시간 0.022초

도시유역 저류형 시스템 설계를 위한 CSOs 산정 (Storm-Water CSOs for Reservoir System Designs in Urban Area)

  • 조덕준;김명수;이정호;박무종;김중훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1199-1203
    • /
    • 2005
  • Combined sewer overflows(CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available(which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a contiunous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban dranage system used analytical Probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics or the subject area using analytical Probabilistic model. Runoff characteristics manifasted the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range 3xDWF(dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a dicision of storage volume for CSOs reduction and water quality protection.

  • PDF

SWMM을 연계한 DEM기반의 도시침수해석 모형 (DEM Based Urban Inundation Analysis Model Linked with SWMM)

  • 이창희;한건연;최규현
    • 한국수자원학회논문집
    • /
    • 제39권5호
    • /
    • pp.441-452
    • /
    • 2006
  • 최근에 홍수재해와 관련된 자연재해가 급격히 증가하고 있다. 특히, 사회기반시설의 집중 및 인구증가로 도시지역에서의 침수는 인명과 재산에 큰 피해를 야기한다. 본 연구의 목적은 배수시스템에서의 과부하로 인한 도시지역에서의 침수심을 계산하기 위해서 우수배수시스템모형과 2차원 지표류모형을 연계한 새로운 모형을 개발하는 것이다. 대상유역에서의 침수유량의 거동은 두 가지 요소로 고려되는데 하나는 배수시스템에서의 흐름이고 다른 하나는 월류유량으로 발생한 범람 흐름으로 고려되어 졌다 개발모형은 군자와 장안유역에 적용되었고, 계산된 침수심들은 모의결과로 제시되었다. 모의 결과는 홍수관계기관이 침수 발생이 예상되는 지점에서 홍수피해 방지를 위해 배수시스템의 용량에 대한 재설계 혹은 확장 등과 같은 대책을 수립하는데 도움을 줄 수 있다. 또한, 본 모형은 홍수관계기관에서의 정책결정에 활용될 수 있도록 침수위험지도를 만들고 홍수경감대책을 수립하는데 이용될 수 있다

도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정 (Estimation of Storage Capacity for CSOs Storage System in Urban Area)

  • 조덕준;이정호;김명수;김중훈;박무종
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

GIS를 이용한 도시지역 침수해석 (Urban Inundation Analysis by Applying with GIS)

  • 이창희;한건연;김지성
    • 한국지리정보학회지
    • /
    • 제9권2호
    • /
    • pp.115-126
    • /
    • 2006
  • 본 연구의 목적은 도시지역에서의 침수시뮬레이션에 필요한 도시침수해석모형을 개발하고, 이를 GIS(geographic information system)와 연계 운영할 수 있는 시스템을 구축함에 있다. 이를 위해서 미국환경보호청(EPA)의 SWMM(storm water management model)모형을 이용하여 도시지역 배수 시스템에서의 도시유역 유출량 및 월류량을 계산하고, 지표면으로 월류된 유량에 대해 GIS를 이용한 침수해석을 실시하였다. GIS를 이용한 침수해석 모형으로는 Level-Pool 침수해석모형과 DEM 기반 침수해석모형을 개발하고 도시지역에서의 시간별 침수위 및 침수범위 등을 계산 할 수 있게 하였다. 도시배수시스템과 지표침수해석모형을 GIS를 이용하여 통합시킨 도시침수해석 모형을 통해서 배수 시설에서의 유출량 예측과 지표면에서의 월류유량의 전파특성을 예측할 수 있도록 구성하였다. 본 연구결과는 도시지역에서의 배수 시설의 설계 및 운영의 문제, 침수 예상도의 작성 및 각종 홍수 예경보 수립에 기여할 수 있을 것으로 판단된다.

  • PDF

합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석 (Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system)

  • 박진규;이남훈;김해룡;이웅;이채영
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

파괴확률과 다중파괴유형을 이용한 우수관의 안전성 분석 (Safety Analysis of Storm Sewer Using Probability of Failure and Multiple Failure Mode)

  • 권혁재;이철응
    • 한국수자원학회논문집
    • /
    • 제43권11호
    • /
    • pp.967-976
    • /
    • 2010
  • 우수관의 성능이 한계상태(performance limit state)에 도달할 확률을 정량적으로 산정할 수 있는 FORM(First-Order Reliability Model)의 AFDA(Approximate Full Distribution Approach) 신뢰성 모형을 개발하였다. 우수관망에서 각각의 관으로 유입하는 유량이 그 관의 허용 가능 배출량을 초과하여 성능한계상태에 도달할 때 이를 파괴상태(failure state)라 정의하여 신뢰함수를 수립하였다. 우수관거로의 유입량은 합리식, 유출량은 Manning의 공식을 적용하였다. 또한 신뢰성 해석을 위한 관련 확률변수들에 대한 통계적 특성과 분포함수에 대한 해석이 수행되었다. 강우자료의 불확실성 해석에서 우리나라 여러 중소도시에 대한 연 최대강우강도의 확률분포가 Gumbel 극치분포함수와 일치함을 확인하였다. 개발된 신뢰성 모형을 Y자형 우수관망에 적용하여 성능한계상태가 발생할 확률, 즉 파괴확률(probability of failure)을 정량적으로 산정하였다. Manning의 공식을 이용하여 우수관의 직경 변화에 따른 파괴확률의 거동특성을 분석하였다. 특히 문경과 대전의 50년 재현기간을 갖는 설계 강우강도에 대한 우수관의 파괴확률을 산정한 결과에 의하면, 관의 직경이 특정수치 이하일 경우 파괴확률이 급격히 커지는 것을 확인할 수 있었다. 이는 실제 우수관의 유효직경이 설계직경에 가깝도록 항상 관내 불순물을 제거하는 것이 파괴확률을 줄이는 최선의 방법임을 의미하는 것이다. 또한 우수관 시스템의 경우 여러 개의 관이 모여 하나의 관으로 흘러 들어가는 경우가 많으며 이 경우 다중파괴유형(multiple failure mode)을 적용하여 시스템이 파괴상태에 도달할 확률을 정량적으로 산정하였다. 본 연구에서 개발된 신뢰성 모형은 우수관의 운용, 관리, 감독은 물론 설계에 활용이 가능 할 것이다.

우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과 (Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control)

  • 임봉수;박윤해;김태응
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

PREDICTION OF COMBINED SEWER OVERFLOWS CHARACTERIZED BY RUNOFF

  • Seo, Jeong-Mi;Cho, Yong-Kyun;Yu, Myong-Jin;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.62-70
    • /
    • 2005
  • Pollution loading of Combined Sewer Overflows (CSOs) is frequently over the capacity of a wastewater treatment plant (WWTP) receiving the water. The objectives of this study are to investigate water quality of CSOs in Anmyun-ueup, Tean province and to apply Storm Water Management Model to predict flow rate and water quality of the CSOs. The capacity of a local WWTP was also estimated according to rainfall duration and intensity. Eleven water quality parameters were analyzed to characterize overflows. SWMM model was applied to predict the flow rate and pollutant load of CSOs during rain event. Overall, profile of the flow and pollutant load predicted by the model well followed the observed data. Based on model prediction and observed data, CSOs frequently occurs in the study area, even with light precipitation or short rainfall duration. Model analysis also indicated that the local WWTP’s capacity was short to cover the CSOs.

하수관망의 간소화가 도시침수 모의에 미치는 영향 분석에 관한 연구 (Study on the influence of sewer network simplification on urban inundation modelling results)

  • 이승수;;정관수;김연수
    • 한국수자원학회논문집
    • /
    • 제51권4호
    • /
    • pp.347-354
    • /
    • 2018
  • 도시유역에서 발생한 유출은 지표면뿐만 아니라 하수관망을 통해 배수되며, 도시침수 모의 수행시 하수관망을 수문학적 배수 시스템의 한 구성요로서 고려하는 것은 매우 중요하다. 그러나 도시 침수 모의를 수행하는 대부분의 연구자들이 적절한 기준에 준하지 않고 직관적으로 하수관망을 단순화시켜 모의를 수행하는 실정이다. 따라서 본 연구에서는 1D-2D 결합 도시침수 해석 모형을 이용하여 수지상 구조에 구분법에 기반하여 단순화된 하수관망의 도시침수 해석 결과에 미치는 영향을 분석하였다. 하수관망 해석을 위한 1차원 모델은 Lee et al. (2017)에 의해 소개된 모형으로서 지표면과 하수관망 사이의 유입과 역류를 동시에 모의할 수 있고, 2차원 지표면 모델은 불규칙 삼각망을 이용하여 지표수 흐름을 모의하며 1차원 하수관망 해석모형과 연계되어 도시침수를 모의할 수 있다. 하수관망은 수지상 구조 구분법에 기반하여 2차, 3차 그리고 단순화 하지 않은 경우로 구분할 수 있으며, 구분된 각 하수관망은 서울시 사당역 인근에 많은 침수 피해를 발생시킨 2011년 7월 27일 강우 사상에 적용하여 제안된 방법의 적용성을 평가하였다. 모든 케이스에 대하여 침수면적, 지표면에서 하수관망으로의 유입 유량, 하수관망에서 지표면으로의 역류 유량 등을 비교하였으며, 마지막으로 하수관망 단순화를 위한 적절한 기준 제시에 대한 논의를 수행하였다.

합류식 하수관거 월류수 처리를 위한 와류형 분리장치의 최적 운전조건 (Optimal Operating Condition of Vortex Separator for Combined Sewer Overflows Treatment)

  • 한정균;주재영;이범준;나지훈;박철휘
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.557-564
    • /
    • 2009
  • A combined sewer system can quickly drain both storm water and sewage, improve the living environment and resolve flood measures. A combined sewer system is much superior to separate sewer system in reduction of the non-point source pollutant load. However, during rainfall. it is impossible in time, space and economic terms to cope with the entire volume of storm water. A sewage system that exceeds the capacity of the sewer facilities drain into the river mixed with storm-water. In addition, high concentration of CSOs by first-flush increase pollution load and reduce treatment efficiency in sewage treatment plant. The aim of this study was to develope a processing unit for the removal of high CSOs concentrations in relation to water quality during rainfall events in a combined sewer. The most suitable operational design for processing facilities under various conditions was also determined. With a designed discharge of 19.89 m/min, the removal efficiency was good, without excessive overflow, but it was less effective in relation to underflow, and decreased with decreasing particle size and specific gravity. It was necessary to lessen radius of vortex separator for increasing inlet velocity in optimum range for efficient performance, and removal efficiency was considered to high because of rotation increases through enlargement of comparing height of vortex separator in diameter. By distribution of influent particle size, the actual turbulent flow and experimental results was a little different from the theoretical removal efficiency due to turbulent effect in device.