• 제목/요약/키워드: Sewage treatment water

검색결과 716건 처리시간 0.03초

합성세제의 오염과 상수정수처리에 의한 그 제거효과에 관한 조사연구 (Studies on Pollution and Reduction of Synthetic Detergents by Tap Water Treatment)

  • 권숙표;정용;심길순
    • 약학회지
    • /
    • 제21권4호
    • /
    • pp.200-210
    • /
    • 1977
  • This investigation was undertaken from February 1976 to September 1976. The detergents in municipal sewages from the Chung Kae Stream, Ahn Yang Stream, and Bong Won Stream were determined at 1.5ppm, 0.93ppm, and 3.36ppm in average respectively. The concentrations of detergents determined in the Han river were 0.013ppm of Kwang Na Ru, 0.11ppm of Duk Do, 0.370ppm of Bo Kwang Dong, and 0.285ppm of Ka Yang Dong basin respectively. And the potable waters of Sung Book Ku and Sung Dong Ku from Ku Eu water pumping station located up-stream of the Han river were less polluted at 0.045ppm and 0.037ppm in average. Young Deung Po Ku and Su Dae Moon Ku had been relatively polluted at 0.181ppm and 0.133ppm. The coagulant, alum [$Al_{2}(SO_{4})_{3}$] could eliminated the small amount of detergent by coagulation. The eliminated rates were about 13% by 5ppm and 22.7% by 20ppm of aluminum sulfate in sewage contained 10ppm of turbidity. The sand and the charcoal adsorbed some detergent as the following Langmuir's equations: For the charcoal, m/x=0.029.$\times$1/Ce-11.43 For the charcoal, m/x=2.705log1/Ce-5.46 Where m: amount of snad and active carbon used(g) x: amount of detergent adsorbed from liquid(g) Ce:concentration in the liquid at equilibrium(miles) The adsorption effect of sand would be neglected. In the low concentration of detergent solution, one gram of active carbon adsorbed 0.263g of detergent. It was determined that one gram of chlorine reduced 5.5g pf DBS om keeping up 0.2ppm of residual chlorine by disinfection process with chlorine compound.

  • PDF

혐기성 미생물부식에 의해 생성되는 철화합물 추정식 개발 (The Development of Estimation Model for Iron Compound Originated from Anaerobic Microbial Corrosion)

  • 전석준
    • 한국물환경학회지
    • /
    • 제18권4호
    • /
    • pp.379-386
    • /
    • 2002
  • In this study, estimation model for iron compound originated from upflow, anaerobic fixed bed reactor, which treats sewage domestic wastewater, was developed. The estimation model was formulated by a mathematical expression which was based on the mass balance. Below the HRT of 60 minute, sulfide concentration combining with iron $FeS_2$ is the highest because the maximum sulfate consumption rate $V_{maxS}$ and half-saturation constant of sulfate $K_{mS}$ exert an important effect on the estimation model as temperature was increased. But increment of $FeS_2$ concentration is weakened above the HRT of 60 minutes and represent the lowest value at the HRT of 108 minutes. It implies that liquid phase distribution ratio of sulfide ${\alpha}r$ becomes lower as temperature was increased. While phosphorus concentration combining with iron $Fe_3(PO_4)_3$ is increased as HRT and temperature are increased, which is affected by phosphorus removal rate constant $k_p$. As the result of estimating the iron concentrations of corrosion by the model, the concentration of iron corrosion is higher than any other at the HRT of 108 minute and $20^{\circ}C$. The predicted values were compared with measured ones at different HRT(13.5, 27, 54, 108 min) and temperature(20, 25, $30^{\circ}C$). The experimental data could be fitted with the simulated curves. Therefore, the mathematical expression could be applicable to design full-scale wastewater treatment plants.

Pilot Scale Plant의 황 충진 MBR을 이용한 고효율의 질소제거 공법 개발 (Development of High-rate Nitrogen Removal Process Using Submerged MBR Packed with Granular Sulfur of Pilot Scale Plant)

  • 문진영;황용우;조현정
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.383-390
    • /
    • 2011
  • In this study, a process combined biofiltration with sulfur-utilizing autotrophic denitrification and membrane separation was proposed to examine the efficiency of nitrogen removal. As an experimental device, hollow-fiber module was installed in the center of reactor to generate the flux forward sulfur layer in the cylinder packed with granular sulfur. In addition, a simple module was installed in activated sludge aeration tank which inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. The experiment for developing new MBR process was carried out for three years totally. As the results of first two-year experiment, successful nitrogen removal performance was revealed with lab-scale test and pliot scale plant using artificial wastewater and actual plating wastewater. In this year, pilot scale test using actual domestic wastewater was performed to prove field applicability. As the results, high-rate nitrogen removal performance was confirmed with about 0.19 kg ${NO_3}^--N/m^3$ day of rate. Also significant fouling and pressure increase were not found during the experiment. And, the production ratio of sulfate and the consumption ratio of alkalinity showed a slightly higher value about 311 mg ${SO_4}^{2-}/L$ and 369 mg $CaCO_3$/L, respectively. In conclusion, the developed MBR process can be utilized as an alternative for retrofiting existing wastewater plants as well as new construction of advanced sewage wastewater treatment plants, with cost-effective merit.

하수종말처리시설 방류수의 하천유량 기여도 분석 (Contribution Degree Analysis of Discharge from Sewage Treatment Plants at Streamflow in River)

  • 문장원;최시중;강성규;이동률
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1370-1374
    • /
    • 2010
  • 하수종말처리시설은 가정 등에서 배출되는 생활하수를 처리하여 오염물질을 제거한 후 다시 하천으로 물을 되돌려 보내는 시설로 하천수의 수질 측면에서 매우 중요한 역할을 수행하고 있다. 그러나 하천수의 수질 측면뿐만 아니라 수량적인 측면에서도 하수종말처리시설은 하천유량 관리에 있어 중요한 고려사항이라 할 수 있다. 하수종말처리시설을 통해 하천으로 방류되는 물은 비교적 일정한 수준을 유지하고 있으며, 이는 평저수기 및 갈수기 하천유량 관리 측면에서 매우 중요한 의미를 갖는다. 효율적인 하천유량 관리를 위해서는 하천을 중심으로 이루어지는 물 순환 구조에 대해 명확하게 파악할 수 있어야 하며, 하천에서 빠져나가는 물의 양과 하천으로 들어오는 물의 양을 파악함으로써 적절한 하천유량 관리가 이루어질 수 있다. 본 연구에서는 하수종말처리시설에서 하천으로 방류되는 물의 양이 하천유량에서 차지하는 비중을 파악하기 위한 분석을 수행하였다. 이를 위해 하수종말처리시설의 처리수 방류위치를 확인한 후 이를 기준으로 인접한 상 하류 하천구간에 유량자료가 생산되고 있는 수위관측시설을 검토하여 분석을 위한 대상 지점을 선정하였다. 선정된 지점을 중심으로 홍수기(6~9월)를 제외한 기간에 대해 하천유량과 하수종말처리시설의 방류수량을 검토하여 하수처리수의 기여도를 분석하였다. 하천유량과의 비교와 함께 분석 대상 지점에 고시되어 있는 하천유지유량과 비교한 후 그 결과를 제시하였다. 본 연구의 결과를 통해 하수처리수가 하천에 흐르는 유량에 기여하는 정도를 파악할 수 있으며, 이는 하천유량이 상대적으로 적은 평저수기 및 갈수기 하천유량 관리를 위한 기반 정보로 활용할 수 있을 것이다.

  • PDF

컴퓨터 시뮬레이션을 이용한 신 생물학적 고도처리 (병렬 고도처리) 공법 개발 (Developing a New BNR (Parallel BNR) Process by Computer Simulation)

  • 이병희;이용운
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.670-678
    • /
    • 2002
  • Since Korean government imposed a stricter regulation on effluent T-N and T-P concentrations from wastewater treatment plant, a new process has to be developed to meet these rules and this process should remove T-N and T-P, economically, from weak wastewater that is typical for Korea's combined sewer system sewage. In this study, a computer simulator, BioWin from EnviroSim, Inc. was used. Three processes - A2/O, Modified Johannesburg, UCT- had been simulated under same operational conditions and a new process - Parallel BNR Process - had been developed based on these simulation results. The Parallel BNR process consists of two rows of reactors: One row has anaerobic and aerobic reactors in series, and the other row has RAS anoxic1 and RAS anoxic2 reactors in series. In order to ensure anaerobic state in anaerobic tank, a part of influent is fed to RAS anoxic1 tank in second row. This process had been simulated under same conditions of other three processes and the simulation results were compared. The results showed that three existing processes could not perform biological phosphorus removal when the average influent was fed at any operation temperatures. However, the Parallel BNR process was found that biological phosphorus removal could be performed when both design and average influent were fed at any operation temperatures. This process showed the T-N concentration in effluent had a maximum value of 15mg/L when design influent was fed at $13^{\circ}C$ and a minimum value of 14mg/L when average influent was fed at $20^{\circ}C$. Also, T-P concentrations had a maximum value of 1.3mg/L when average influent was fed at $20^{\circ}C$ and a minimum value of 1.1mg/L when design influent was fed at $13^{\circ}C$. Based on these results, we found that this process can remove nitrogen and phosphorus biologically under any operational conditions.

낙동강 유역 내 하수처리구역의 비점오염원 부하량에 대한 비점저감 기여율 분석 (Nonpoint Removal Contribution Ratio Analysis of Nonpoint Source Pollutants Loads from Sewage Treatment Area in Watershed of Nakdong River)

  • 장종경;김미은;김재문;장영수;신현석
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.445-445
    • /
    • 2015
  • 비점오염의 특성에 대해 지속적으로 연구 중이지만 수문특성과 연관성이 크다 보니 그 일관성에 대해 확실한 기법이 개발되지 않았다. 기법 개발과 효과적인 오염원 관리를 위해 SWMM 등의 모형을 활용하고 있지만 투입된 노력과 시간에 비해 그 효율성이 매우 적은 편이다. 이런 부분을 보완하고자 본 논문에서는 기존의 비점오염량 산정방법이 아니라 낙동강유역의 도시화 특성 및 수문/기상자료와 처리장 운영자료를 활용한 차별화된 원단위법을 통해 비점 배출 부하량 산정방법을 제시하려고 한다. 배수구역 내 관거 시스템을 합류식으로 가정하였고 배수구역별 비점 발생형태는 하수처리장의 강우 유입량, 하수처리장의 우회유량(Bypass 유량), 하수처리구역의 CSO 유량 3가지로 구분 지었다. 유입 방류자료와 강우자료를 활용하여 임계강우량을 3mm로 설정하여 3mm이상일 경우에 우회유량이 발생한다고 가정하였고 우회유량 발생시 오염부하량 산정은 건기평균유량에 유량변동부하율을 곱하여 시간최대유량으로 전환한 후 강우 지속기간 동안만 우회유량이 발생하는 것으로 가정하였다. CSO 유량은 처리구역/배수구역 면적비에 따라 3개의 그룹으로 구분한 뒤 검증된 SWMM-온천천 모형의 각 소유역별 불투수면적비와 비교하여 유사한 소유역을 각 그룹의 대표유역으로 선정하였다. 선정된 소유역의 CSO 유량과 수문현상의 비선형적인 관계를 고려할 수 있는 신경망 기법을 적용하여 강우특성에 따른 CSO 오염부하량 산정을 실시하였다. 산정결과를 바탕으로 각 하수처리장별 비점저감 기여율을 산정한 결과 대구북부 처리장에서 21.56%로 가장 높은 효율을 보여줬으며 거창가조 지점에서 0.11%로 가장 낮은 효율을 보여주는 것을 확인 할 수 있었다. 이러한 결과를 바탕으로 낙동강유역 내 위치한 하수처리장의 효율성에 대해 알 수 있으며 개선되어야 할 처리장들을 알 수 있었다. 또한 획일화된 방법이 아닌 차별화된 원단위법을 통한 오염부하량 산정은 앞으로의 연구방향에 있어서 좋은 사례가 될 것으로 사료된다.

  • PDF

친환경 인공습지 조성을 통한 하수처리 방류수 재처리 효과분석 (Analysis of Efficiencies in pro environmental constructed Wetlands for Treating sewage treatment effluent)

  • 임건묵;박소미;하은정;이종진
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.220-220
    • /
    • 2020
  • 영산강수계는 상류에 4개의 농업용 댐이 위치하여 환경대응용수 확보 및 하천유지유량이 절대적으로 부족하고, 갈수기 하천 유량의 약 67 %가 광주 제 1, 2 하수처리장 방류수가 차지하고 있어 하천의 수질과 수생태계를 위협하고 있다. 이에 최근에는 오염된 하천의 건강성을 회복하기 위한 방법으로 수생태계의 정화능력을 활용한 인공습지가 각광받고 있다. 영산강 유역에서도 자연의 정화능력을 활용하여 하천 오염원을 저감시키기 위한 사업의 일환으로 2016년 광주 제 2 하수처리장 방류구에 서창오미공원 습지를 조성하였다. 이 습지는 유입량이 적어 정상적 기능이 어려운 기존 습지를 재조성한 것으로 하수처리장 방류수 약 5만 ㎥/day을 습지로 유입시켜 수질정화용 식재식물을 이용하여 하수처리장 방류수 수질을 개선한 사업이다. 2016~2017년 모니터링 결과, 습지 유입 전·후 BOD는 평균 33.5 %, 최대 73.1 % 저감 되었으며, T-P 또한 평균 59.3 %, 최대 91.6 % 저감 되었다. 그러나 습지는 운영기간 경과 시 퇴적물 축적, 고사체로 인한 T-P 용출 등으로 인하여 처리수의 수질이 더 악화될 우려가 있기 때문에 습지 조성 후 지속적인 유지관리와 모니터링이 필요하다. 그 예로 하수처리장 방류수와 비점오염원 처리를 위해 주암호에 조성된 인공습지의 경우, 2001년 준공 후 지속적인 관리 및 모니터링을 통하여 약 17년이 지난 2018년에도 BOD 49.3 % T-N 65.1 %, T-P 19.2 % 로 저감되어 오염원 및 영양염류 제거에 큰 효과가 있는 것으로 나타났다. 따라서 본 조사에서는 서창오미공원과 주암호 인공습지 운영 결과를 토대로 습지 모니터링의 중요성과 적정 운영 방안을 제시하고자 하며, 영산강 하천의 점·비점오염원 저감을 위한 신규 인공습지 조성 사업에 기초자료로 활용하고자 한다.

  • PDF

염색 폐수 슬러지를 활용한 탄소저감형 이산화티타늄 제조 및 특성 분석 (Carbon-Reduced Titanium Dioxide Production and Characterization Using Dyeing Wastewater Sludge)

  • 김종규
    • 한국재료학회지
    • /
    • 제34권5호
    • /
    • pp.254-260
    • /
    • 2024
  • This study is to manufacture a titanium dioxide (TiO2) photocatalyst by recycling sludge generated using titanium tetrachloride (TiCl4) as a coagulant. Compared to general sewage, a TiCl4 coagulant was applied to dyeing wastewater containing a large amount of non-degradable organic compounds to evaluate its performance. Then the generated sludge was dried and fired to prepare a photocatalyst (TFS). Scanning electron microscope-energy dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), and nitrogen oxide reduction experiments were conducted to analyze the surface properties and evaluate the photoactive ability of the prepared TFS. After using titanium tetrachloride (TiCl4) as a coagulant in the dyeing wastewater, the water quality characteristics were measured at 84 mg/L of chemical oxygen demand (COD), 10 mg/L of T-N, and 0.9 mg/L of T-P to satisfy the discharge water quality standards. The surface properties of the TFS were investigated and the anatase crystal structure was observed. It was confirmed that the ratio of Ti and O, the main components of TiO2, accounted for more than 90 %. As a result of the nitric oxide (NO) reduction experiment, 1.56 uMol of NO was reduced to confirm a removal rate of 20.60 %. This is judged to be a photocatalytic performance similar to that of the existing P-25. Therefore, by applying TiCl4 to the dyeing wastewater, it is possible to solve the problems of the existing coagulant and to reduce the amount of carbon dioxide generated, using an eco-friendly sludge treatment method. In addition, it is believed that environmental and economic advantages can be obtained by manufacturing TiO2 at an eco-friendly and lower cost than before.

영산강수계 의료기원 방사성요오드(131I) 핵종의 분포 및 거동평가 (The Distribution and Behavior of Medically-derived 131I in the Yeongsan River Basin)

  • 강태우;한영운;박원표;송광덕;황순홍;강태구;김경현
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.243-250
    • /
    • 2018
  • 본 연구는 영산강 수계에 위치한 하수처리장 및 하천 중 인공방사성핵종 $^{131}I$의 농도 분포와 하천에서 거동 평가로부터 기원을 확인하고자 수행하였다. 조사지점은 하천 중 본류 13개 및 지류 4개 지점과 하수처리장 2개 지점을 포함하여 총 19개 지점을 선정하였다. $^{131}I$ 방사능 분석은 고순도 게르마늄 검출기와 다중파고분석기로 구성된 감마분광계를 이용하여 계측하였다. 하수처리장 중 $^{131}I$ 핵종은 두 지점의 방류수에서 대부분 검출되었으나, 하천의 표층수는 2017년 상반기(MS4, MS10) 및 하반기(MS4, MS7)에만 각각 두 지점에서 검출되었다. 하수처리장 방류수 중 $^{131}I$ 농도는 각각 0.0870~3.87 Bq/L 및 MDC 이하~0.534 Bq/L, 검출된 하천 표층수는 0.0908~0.174 Bq/L 범위였다. 하천에서 $^{131}I$ 거동 평가 결과, 본류 중에서 가장 상류와 지류의 하천 지점들에서는 검출되지 않았고, 반면 하수처리장과 이들의 영향을 받는 하류의 하천 지점들에서는 지속적으로 검출되었다. 하지만 하류 하천으로 갈수록 감소하다가 불검출 되어 하수처리장과 밀접한 관계가 있었다. 이상의 결과, 하천에서 검출되는 $^{131}I$ 핵종은 하수처리장에서 유래된 것으로 의료 기원임을 확인할 수 있었다.

승기천 유역의 오염물 유출특성 및 수질관리방안 연구 (A Study on the Runoff Characteristics and Water Quality Management of Seung-Gi Stream Area)

  • 서형준;정상원;박미옥;이병렬
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.251-263
    • /
    • 2001
  • 본 연구는 인천광역시의 주요 하천인 승기천의 현재 오염현황과 특성, 오염원을 분석하고 승기천 회복방안 마련을 위한 기초자료를 얻기 위해 수행되었다. 승기천을 5 구간으로 나누어 10 회에 걸친 시료채취를 하였으며, 유량, pH, DO, SS, $BOD_5$, $COD_{Cr}$, T-P, TKN 등과 Zn, Cd, Cu, Cr 원소의 농도를 측정하여 강우와 무강우시 승기천으로 유입되는 각 구간별 오염부하특성, 연간 오염부하량을 선정하였다. 남동공단이 밀접해 있는 하류구간으로 갈수록 구간별 유입부하가 매우 컸으며 전 구간에 걸쳐 하천 수질 환경기준을 크게 상회함을 알 수 있었고, 인천연안 오염에 큰 영향을 끼칠 것이 우려되었다. 이를 해결하기 위한 방안으로 승기 하수처리장 처리수, 승기 하수처리장 처리수의 URC(ultra rapid coagulation) 재처리수의 순환과 승기천으로 직접 유입되는 하폐수를 차집 처리하는 것을 가정하여 수질을 예측해 봄으로써 승기천의 하천으로서의 역할 회복 방안을 모색해 보았다.

  • PDF