Effects of Gumi City Sewage Treatment Effluent in the Downstream Nutrient Matter: Comparison of Daily Loading (구미시 하수처리 방류수가 하류 하천 영양염류에 미치는 영향: 부하량 비교)

  • Seong, Jin-Uk;Lee, Sang-Pal;Lee, Jae-Kyun;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1643-1650
    • /
    • 2013
  • This study investigated water quality of effluents and stream from the sewage treatment plants located at Gumi Complex 4, Gumi, and Wonpyeong in Gumi. Downstream region was found to increase the concentration of nutrients for sewage treatment plant effluent. Both phosphorus and nitrogen were accounted most as soluble form. In particular, the high ratio of dissolved effluent of sewage treatment plants were investigated. In the streams, Phosphorus concentration was high during rainy season and nitrogen concentration was high in the dry season. Sewage treatment plant effluent was relatively less microbial activity and nutrient concentrations were higher in the winter. TN/TP ratio was the highest in the upstream region and the lowest in the sewage treatment plant effluent. The effect of the nutrient matter from a discharge of a sewage treatment plant on rivers varied depending on the size of the river and the treatment plant. However, the influence of the concentration was greater than that of flowrate. Sewage treatment plant effluent loads phosphorus, nitrogen accounted for 8% and 6% respectively at the point N3 of the Nakdong river.

A Study on the Management System Improvement of Effluent Water Qualities for Public Sewage Treatment Facilities in Korea (우리나라 공공하수처리시설의 방류수 수질 관리체계 개선방안 고찰 - 미국, 일본, 유럽의 공공하수처리시설 방류수 수질 관리제도를 중심으로 -)

  • Jeong, Donghwan;Choi, Incheol;Cho, Yangseok;Chung, Hyenmi;Kwon, Ohsang;Yu, Soonju;Yeom, Icktae;Son, Daehee
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.4
    • /
    • pp.296-314
    • /
    • 2014
  • In recent years, Ministry of Environment (MOE) has been implementing a phased strengthening of the effluent standards for sewage treatment plants. In this regard, a comprehensive system should be developed to help check the appropriateness of such standards by specifying the grounds for standard-setting and investigating the current operation of sewage treatment plants clearly. It is necessary to establish a new standard-setting system for the effluent that is in a closer connection with the environmental criteria and rating systems. In the United States, the federal government provides guidelines on the least provisions and requirements for the Publicly Owned Treatment Works (POTWs). Local governments set the same or stricter guidelines that reflect the characteristics of each state. In Japan, the sewage treatment plants are subject to both the effluent standards and the discharge acceptable limits to pubic waters under the sewerage law. Specific requirements and limits are set in accordance with local government regulations. The European Union imposes sewage treatment plants with different provisions for effluent standards, depending on the sensitivity of public waters to eutrophication. The effluent standards for sewage treatment plants are classified by pollutant loads discharged to receiving waters. MOE also needs to introduce systems for setting new parameter standards on a POTW effluent by applying statistical means and treatment efficiencies or optimal treatment techniques, as seen in the cases of the US National Pollutant Discharge Elimination System (NPDES) or the EU Integrated Pollution Prevention and Control (IPPC).

Wastewater Treatment Plant Data Analysis Using Neural Network (신경망 분석을 활용한 하수처리장 데이터 분석 기법 연구)

  • Seo, Jeong-sig;Kim, Tae-wook;Lee, Hae-kag;Youn, Jong-ho
    • Journal of Environmental Science International
    • /
    • v.31 no.7
    • /
    • pp.555-567
    • /
    • 2022
  • With the introduction of the tele-monitoring system (TMS) in South Korea, monitoring of the concentration of pollutants discharged from nationwide water quality TMS attachments is possible. In addition, the Ministry of Environment is implementing a smart sewage system program that combines ICT technology with wastewater treatment plants. Thus, many institutions are adopting the automatic operation technique which uses process operation factors and TMS data of sewage treatment plants. As a part of the preliminary study, a multilayer perceptron (MLP) analysis method was applied to TMS data to identify predictability degree. TMS data were designated as independent variables, and each pollutant was considered as an independent variables. To verify the validity of the prediction, root mean square error analysis was conducted. TMS data from two public sewage treatment plants in Chungnam were used. The values of RMSE in SS, T-N, and COD predictions (excluding T-P) in treatment plant A showed an error range of 10%, and in the case of treatment plant B, all items showed an error exceeding 20%. If the total amount of data used MLP analysis increases, the predictability of MLP analysis is expected to increase further.

Performance Analyzing Technique of Small Hydro Power (소수력발전 성능특성 분석기법 연구)

  • Park, W.S.;Lee, C.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • A methodology to predict the output performance of small hydro power using discharge of sewage treatment plant has been studied. Two sewage treatment plants existing in Chunrabuk-Do were selected and the output performance characteristics for these plants were analyzed, using developed model. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power using discharge of sewage treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed for two plants.

  • PDF

Protozoa as an Indicator of Activated In Sludge Plant Effluent Quality (원생동물을 이용한 하수처리장의 수질 예측)

  • 이찬형;문경숙
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.6
    • /
    • pp.361-366
    • /
    • 2000
  • Genera and number of protozoa were investigated in the conventional activated sludge pilot plant used for the treatment of municipal sewage and pre-treated night soil-containing sewage. In both case, the predominant protozoa was ciliates and among them Vorticella was the most common. In the pilot plant where pre-treated night soil was mixed with municipal sewage, genera of free-swimming ciliates, flagellates and amoeba was higher than in those withour night soil. Correlation analysis on the quality of effluent and protozoa indicates that municipal sewage has positive correlation with protozoa. However in the pilot plan 샐 sewage contatinin pre-treated night coil soil more samples show negative correlation. Followed equations were derived by the regression analysis of BOD in both the pilot plants. In case of pilot plant A of municipal sewage, the analysis B of munici-pal and pre-treated night soil-containing sewage, the analysis of BOD was $6.731$\times$10_{-2}$ $\times$Bodo+0.306(Adjusted $R^2$=0.864). At low temperature, number of protozoa was decreased to 35% and among therm, Aspidisca was the most common genus. Therefore, protozoa can be used as indicator of quality of the effluent in sewage treatment plants.

  • PDF

Effects of Fertilizer and Sewage Sludge Treatments on Germination and Growth of Woody Plants in Metal Mine Tailings

  • Lee, Sul-Ki;Cho, Do-Soon
    • The Korean Journal of Ecology
    • /
    • v.23 no.6
    • /
    • pp.445-452
    • /
    • 2000
  • The effects of sludge and fertilizer application on germination and seedling growth of woody plants on heavy metal mine tailings were evaluated by greenhouse experiment. Two different mine tailings (Lead-zinc mine tailings from Kwangmyong, Kyonggi-do and tungsten mine tailings from Sangdong. Kangwon-do). four fertilizer treatments (N +P +K: 20, 40, 60, and 80 kg/m$^3$), and four sewage sludge treatments (5.5, 11, 22.5, and 45 Mg/m$^3$) were used in the experiment. Tested plants were Pinus densiflora, Larix leptolepis, Amorpha fruticosa, and Alnus hirsuta. There were three replicates for each treatment. In addition, vermiculite was used instead of mine tailings to determine the effect of physical amendments. Fifty seeds of a species were sown in a pot (upper diameter 13.5 cm, depth 10 cm) and seedling emergence were recorded daily for 30 days. The highest germination rate was 53% for all treatments. Germination rate of Larix leptolepis was lowest among the four species studied. One month later after seeding, seedlings were thinned and only 5 seedling were left in each pot, and fertilizer and sewage sludge were applied once again. Growth of seedlings were determined for 10 weeks since then. Most plants grew very poorly or died within 5 weeks on lead/zinc mine tailings from Kwangmyong. The analysis of heavy metal contents by the total dissolution method showed that heavy metals generally increased in the order of tungsten mine tailings from Sangdong < sewage sludge from Puchon < lead/zinc mine tailings from Kwangmyong. Growth of woody plants was improved significantly by the fertilizer treatments on tungsten mine tailings. In contrast. survival and growth of woody plants were not affected significantly by the sewage sludge treatment on both tailings. This study shows that fertilizer applied to established seeded stands may provide some benefits in terms of increased ground cover in the field. It is suggested that reclamation should be proceeded by the study of the physico-chemical and biological characteristics of mine tailings.

  • PDF

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.85-88
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PARs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRT AP) of Europe. A method of the gas chromatographic-mass spectrometric (GC-MS) determination of PARs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PARs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PARs sewage sludge samples varied from 2.44 to 4.82 ${\mu}g$/g. Concentration of emission carcinogen PARs(PARcarc), such as Benzo(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Dibenzo(a, h)anthracene and Indeno(1, 2, 3-cd)pyrene ranged from 0.62 to 1.03 ${\mu}g$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PARs and $\sum$PAHcarc from sewage treatment plants had several pathway each by-products. In the ocean dumping, PAHs and $\sum$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year. In recycle, PAHs and $\sum$PAHcarc emissions were 98.36 kg/year and 428.87 kg/year. In the landfill, PAHs and $\sum$PAHcarc emissions were 190.40 kg/year and 830.21 kg/year. In the incineration, PAHs and $\sum$PAHcarc emission were 33.10 kg/year and 830.21 kg/year. (In case of incineration, the whole provisions of PARs and $\sum$PAHcarc contained to flowed in sludge was supposed to be exhausted to environment through exhaust after incineration.)

  • PDF

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.12 no.11
    • /
    • pp.1167-1171
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRTAP) of Europe. A method of the gas chromatographicmass spectrometric (GCMS) determination of PAHs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PAHs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PAHs sewage sludge samples varied from 2.44 to 4.82 $\mu\textrm{g}$/g. Concentration of emission carcinogen PAHs(PAHcarc), such as Benzo(a)anthracene, Benzo(b)f1uoranthene, Benzo(k)f1uoranthene, Benzo(a)pyrene, Dibenzo(a,h)anthracene and Indeno( 1,2,3-cd)pyrene ranged from 0.62 to 1.03 $\mu\textrm{g}$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PAHs and $\Sigma$PAHcarc from sewage treatment plants had emitted to environment by several pathway. The highest amount of emission to the environment was remarked in the ocean dumping(PAHs and $\Sigma$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year, respectively).

The Sludge Collection Scheduling and Vehicle Routing Strategies (하수처리시설의 슬러지 수거 일정계획 수립 및 수거차량 경로결정)

  • Kim Min-Je;No Ui-Su;Heo Eun-Jeong;Choi Gyeong-Hyeon
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.1170-1177
    • /
    • 2006
  • We apply VRP(Vehicle Routing Problem) to sludge collection system in this study. Sewage stores of villages are located in each village around a multipurpose dam. Sludge which is produced in sewage store of village is transported from the sewage store of village to the sewage treatment plants by the special purpose vehicle such as the tank lorry. In this paper, we propose sludge collection strategies which allocate each sewage store of village to sewage treatment plants and decide the schedule of sludge collection in order to collect sludge efficiently. The strategies aim to decrease transportation cost with deciding proposed vehicle routing and scheduling the sludge collection. When we decide route of vehicles, we consider the collection time in sewage store of village, distance between sewage store of villages and vehicle information as average velocity of vehicle, operation time of vehicle driver. We also develop the SCMS(Sludge Collection Management System) based on windows system with real data which is used in certain circumstance. And we experiment to figure out vehicle route and transportation cost throughout changing input data.

  • PDF

A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration (복합악취 농도와 황화수소 농도를 이용한 국내 하수처리시설의 악취발생 특성에 대한 연구)

  • Ko, Byung-Churl;Lee, Jong-Kuk;Lee, Yoon-Su;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1379-1388
    • /
    • 2012
  • Odor from sewage treatment plants have the potential to cause significant annoyance and to impact the amenity. In this study, odor emission characteristics at unit process of 48 sewage treatment facilities in 39 plants were evaluated using composite odor concentration and hydrogen sulfide ($H_2S$) concentration. The values of composite odor concentration (geometry mean) and $H_2S$ concentration (median) for sludge treatment processes are higher than those for the other treatment processes. The composite odor concentration and $H_2S$ concentration are distributed over a wide area in each process. Composite odor concentration (dilution ratio) was found to have the significant correlation with $H_2S$ concentration (p=0.000<0.05). The $H_2S$ concentration accounted for 67.1% of composite odor concentration.