• Title/Summary/Keyword: Setting parameters

검색결과 504건 처리시간 0.026초

최적서비스수준과 예측오차수정에 의한 안전재고 결정 (The Safety Stock Determination by the Optimal Service Level and the Forecasting Error Correcting)

  • 안동규;이상용
    • 산업경영시스템학회지
    • /
    • 제19권37호
    • /
    • pp.31-40
    • /
    • 1996
  • The amount of safety stock is decided from various information such as the forecasted demand, the lead time, the size of the order quantity and the desired service level. There are two cases to consider the problem of setting safety stock when both the demand in a period and the lead time are characterized as random variables: the first case is the parameters of the demand and lead time distributions are known, the second case is they are unknown and must be estimated. The objective of this study is to present the procedure for setting safety stocks in the case the parameters of the demand and lead time distributions are unknown and must be estimated. In this study, a simple exponential smoothing model is used. to generate the estimates of demand in each period and a discrete distribution of the lead time is developed from historical data, and the optimal service level is used which determined to consider both of a backorder and lost sale.

  • PDF

UPFC연계시 거리계전기 동작특성에 따른 보호 관리 시스템 (Protective Management System followed Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;조종만;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.296-298
    • /
    • 2001
  • This paper represents protective management system for transmission line involving the UPFC(Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover, depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. Therefore, established protective system should be taken into account the variable injected voltage of the UPFC and constructed data base system.

  • PDF

송전선로에 UPFC연계시 거리계전기 동작특성에 관한 연구 (A Study on Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller)

  • 서정남;정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2001
  • This paper represents impedance calculation of the distance relay using PSCAD/EMTDC software for transmission line involving the UPFC (Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. The presence of the UPFC in the fault loop affects both voltage and current seen by relay. Therefore, the distance relay should be taken into account the variable injected voltage of the UPFC.

  • PDF

컴퓨터 통합 생산을 위한 통신망의 성능 관리 (Performance Management of Communication Networks for Computer Intergrated Manufacturing)

  • Lee, S.
    • 한국정밀공학회지
    • /
    • 제11권4호
    • /
    • pp.126-137
    • /
    • 1994
  • Performance management of computer networks is intended to improve a given network performance in order for more efficient information exchange between subsystems of an integrated large-scale system. Importance of perfomance management is growing as many functions of the large- scale system depend on the quality of communication services provided by the network. The role of performance management is to manipulate the adjustable protocol parameters on line so that the network can adapt itself to a dynamic environment. This can be divided into two subtasks : performance evaluation to find how changes in protocol parameters affect the network performance and decision making to determine the magnitude and direction of parameter adjustment. This paper is the first part of the two papers focusing on conceptual design, development, and evaluation of performance management for token bus networks. This paper specifically deals with the task of performance evaluation which utilizes the principle of perturbation analysis of discrete event dynamic systems. The developed algorithm can estimate the network performance under a perturbed protocol parameter setting from observations of the network operations under a nominal parameter setting.

  • PDF

전기비저항 측정을 이용한 콘크리트 응결시점 평가 (Setting Time Evaluation of Concrete Using Electrical Resistivity Measurement)

  • 이한주;임홍재
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.361-369
    • /
    • 2017
  • 고성능 콘크리트의 개발로 인해 다양해지는 배합비에 따라, 콘크리트 초기강도 발현 시점을 예측할 수 있는 응결시점에 대한 관심이 높아지고 있다. 기존의 콘크리트 응결시간 측정을 위해 사용되고 있는 관입저항시험은 습식체가름을 실시한 모르타르를 이용한 간접적인 측정법으로, 현장 타설된 콘크리트의 정확한 응결시간을 나타내기 어렵다. 따라서 콘크리트에 직접 측정이 가능한 초음파 속도 측정법, 수화열 측정법, 전기 임피던스 측정법 등 다양한 비파괴 평가 기법들이 제안되고 있다. 본 연구에서는 수화 반응에 따른 시멘트계 재료 내부 전기전도성 변화를 측정하는 4-전극법을 이용하여 콘크리트의 전기 비저항 측정 기법을 제안하고자 한다. 다양한 배합비에 따라 시멘트 페이스트, 모르타르, 콘크리트의 전기 비저항 측정을 실시하였으며, 배합 후 24시간 측정결과로부터 초기 전기비저항 값과 전기비저항 상승시기를 측정 변수로 제안하였다. 또한, 관입 저항 시험에 따른 초결, 종결 시점과의 비교 분석을 통해 콘크리트 응결시점 평가를 위한 제안 기법의 적용 가능성을 확인하였다.

디지털 신호처리 칩(GCD4101)을 사용한 컬러 CCD 카메라 구현 (Implementation of color CCD Camera using DSP(GCB4101))

  • 권오상;이응혁;민홍기;정정석;홍승홍
    • 센서학회지
    • /
    • 제8권1호
    • /
    • pp.69-79
    • /
    • 1999
  • 본 연구에서는 CCD 카메라 전용의 디지털 신호 처리기(DSP)를 이용하여 고해상도의 CCTV 카메라를 구현하였다. 기존의 아날로그 신호 처리기를 사용한 CCTV 카메라는 카메라의 기본 기능인 자동노출(AE), 자동백색조정(AWB), 역광보정(BLC) 등의 처리에 한계점을 갖고 있으며, 영상의 열화 현상이 심하고, 카메라를 생산하는 경우에 조정 매개변수를 수동으로 조정하여야 하는 등 여러 가지 문제점을 내포하고 있다. 따라서 본 연구에서는 이상의 문제점을 해결하기 위하여 국산의 CCD 카메라 전용의 디지털 신호 처리기를 사용하여, 이를 마이컴으로 제어함으로써 자동노출, 자동백색조정, 역광보정 둥의 처리를 화상의 질에 따라 자동으로 조절할 수 있도록 하였다. 또한 마이컴의 채택으로 화면에 문자를 표시하는 기능을 구현함으로써 사용자와의 대화적 형식의 카메라 제어가 가능하도록 구현하였으며, 생산 과정에서 수동으로 카메라 동작 매개 변수를 조정하여야 하는 문제점을 해결하기 위하여 전자적인 가변저항(EVR)을 채택하였다. 그 결과 카메라 조정 변수를 프로그램에 의해 조정하는 것이 가능해졌으며 파라미터 값의 재현성 및 조정 용이성 부분에서의 신뢰성과 조정시간의 감소로 인한 생산단가 절감의 효과를 가져올 수 있었다.

  • PDF

노인에서 임상적 균형평가 지수들의 유용성 : 힘판을 이용한 균형평가와의 상관관계 (The Usefulness of Clinical Balance Tests in Elderly : Correlation of Balance Evaluation using by Forceplate)

  • 우영근;황수진;이우형
    • PNF and Movement
    • /
    • 제8권1호
    • /
    • pp.67-77
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the usefulness of clinical balance tests through the correlation of balance evaluation using by forceplate in elderly. Methods : Thirty nine healthy elderly subjects (14 males, 25 females) participated in the study. The subjects were evaluated with clinical balance tests [(Berg balance scale (BBS), Functional reach test (FRT), Tinetti's performance oriented mobility assessment (POMA), and one leg standing (OLS)]. Static balance evaluation was assessed by using forceplate. Center of pressure (COP) parameters were obtained using it as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened and closed, (2) uncomfortable standing with eyes opened and closed. After static balance evaluation tested, dynamic balance evaluation was assessed. COP parameters were error distance and area during sine curve trace. COP parameters were movement time, error distance, and maintained time in the circle during COP movement task. Results : Clinical balance tests showed statistically significant correlation between static and dynamic balance evaluations. Among the clinical balance tests, the BBS, POMA, and OLS showed significant correlation with to assess the balance ability of elderly in clinical setting both evaluations. Conclusion : Clinical balance tests can be recommended in clinical setting because of low costs and simplicity.

  • PDF

적응형 파라미터 알고리즘을 이용한 개별 소음원의 음향파워 예측 연구 (Parameter-setting-free algorithm to determine the individual sound power levels of noise sources)

  • 문성호
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.59-64
    • /
    • 2018
  • PURPOSES : We propose a parameter-setting-free harmony-search (PSF-HS) algorithm to determine the individual sound power levels of noise sources in the cases of industrial or road noise environment. METHODS :In terms of using methods, we use PSF-HS algorithm because the optimization parameters cannot be fixed through finding the global minimum. RESULTS:We found that the main advantage of the PSF-HS heuristic algorithm is its ability to find the best global solution of individual sound power levels through a nonlinear complex function, even though the parameters of the original harmony-search (HS) algorithm are not fixed. In an industrial and road environment, high noise exposure is harmful, and can cause nonauditory effects that endanger worker and passenger safety. This study proposes the PSF-HS algorithm for determining the PWL of an individual machine (or vehicle), which is a useful technique for industrial (or road) engineers to identify the dominant noise source in the workplace (or road field testing case). CONCLUSIONS : This study focuses on providing an efficient method to determine sound power levels (PWLs) and the dominant noise source while multiple machines (or vehicles) are operating, for comparison with the results of previous research. This paper can extend the state-of-the-art in a heuristic search algorithm to determine the individual PWLs of machines as well as loud machines (or vehicles), based on the parameter-setting-free harmony-search (PSF-HS) algorithm. This algorithm can be applied into determining the dominant noise sources of several vehicles in the cases of road cross sections and congested housing complex.

Relationship between sonorheometry parameters and laboratory values in a critical care setting in Italy: a retrospective cohort study

  • Antonio Romanelli;Renato Gammaldi;Alessandro Calicchio;Salvatore Palmese;Antonio Siglioccolo
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.210-216
    • /
    • 2023
  • Purpose: This preliminary retrospective cohort study analyzed the relationship between the parameters provided by sonorheometry device Quantra and the coagulation values obtained from standard venous blood samples in patients admitted in intensive care unit (ICU). Methods: We reviewed medical charts of 13 ICU adult patients in whom at least one coagulation study with Quantra was performed. The relationship between Quantra and laboratory data was analyzed with the Spearman rank correlation coefficient (rho). The 95% confidence interval (CI) was computed. A P-value <0.05 was considered statistically significant. Results: We collected 28 data pairs. Statistically significant moderate correlations were found for the following parameters: clot time (CT) and activated partial thromboplastin time (rho=0.516; 95% CI, 0.123-0.904; P=0.009; clot stiffness (CS) and the international normalized ratio (INR; rho=0.418; 95% CI, 0.042-0.787; P=0.039); INR and platelet contribution to CS (rho=0.459; 95% CI, 0.077-0.836; P=0.022); platelet count and platelet contribution to CS (PCS; rho=0.498; 95% CI, 0.166-0.825; P=0.008); and fibrinogen and fibrinogen contribution to CS (FCS; rho=0.620; 95% CI, 0.081-0.881; P=0.001). Conclusions: Quantra can provide useful information regarding coagulation status, showing modest correlations with the parameters obtained from laboratory tests. During diffuse bleeding, CT and FCS values can guide the proper administration of clotting factors and fibrinogens. However, the correlation of INR with CS and PCS can cause misinterpretation. Further studies are needed to clarify the relationship between Quantra parameters and laboratory tests in the critical care setting and the role of sonorheometry in guiding targeted therapies and improving outcomes.