• 제목/요약/키워드: Series-flow type

검색결과 168건 처리시간 0.023초

흡수식 냉동기에서 흡수액이 증발기로 혼입시 냉각용량과 성능계수에 미치는 영향 (The Influences of the Refrigerant Adulteration by an Absorbent on the Cooling Capacity and COP of the Absorption Chiller)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.753-760
    • /
    • 2006
  • The purpose of the present work is to investigate the influence of the refrigerant adulteration by LiBr solution on the cooling capacity and COP for three different types of abso게tion chillers: a single-effect type, a series-flow double-effect type and a parallel-flow with double-effect type. A simulation program has been prepared for the cyclic analysis of absorption chillers. With some assumptions, the calculations have been performed by solving the mass balance equation, energy balance equation and the state equation simultaneously. The range of the LiBr concentration of refrigerant was 0% to 20% in the present study. For the single-effect absorption chiller, the maximum decrease in the cooling capacity was 10% at the 20% of LiBr concentration. For the double-effect chiller, the capacity was decreased by 11.1% for the parallel-flow type and the series-flow type. Also, the COP was reduced by 3.0% in single-effect, 2.8% in series-flow type (SR=0.4) and 2.3% in parallel-flow type.

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

A Method of Evaluating Profitability and Risk of Multiple Investments Applying Internal Rate of Return

  • Mizumachi, Tadahiro
    • Industrial Engineering and Management Systems
    • /
    • 제9권2호
    • /
    • pp.121-130
    • /
    • 2010
  • In today's uncertain economic environment, economic risk is inherent in making large investments on manufacturing facilities. It is, therefore, practically meaningful to divide investment over multiple periods, reducing the risk of investment. Then, the cash-flow over the entire planning horizon would comprise positive inflow and negative outflow. In this case, in general, evaluation by internal rate of return (IRR) is not feasible, because multiple IRRs are involved. This paper deals with a problem of evaluating profitability, as well as risk, of investment alternatives made in multiple times of investment over the entire horizon. Typically, an additional investment is required after the initial one, for expanding manufacturing capacity or other reasons. The paper pays attention to a unit cash-flow over two periods, decomposing the total cash-flow into a series of unit cash-flow patterns. It is easy to evaluate profitability of a unit cash-flow by using IRR. The total cash-flow can be decomposed into the series of two types of unit cash-flows: an investment type one (negative-positive) and the borrowing type one (positive-negative). This paper, therefore, proposes a method in which only the borrowing type unit cash-flow is eliminated in the series by converting total cash-flow using capital interest rate. Then, a unique IRR can be obtained and the profitability is evaluated. Thus, the paper extends the method of IRR so that it may help decision making in complicated cash-flow pattern observed in practice.

Interfacial Boundary Estimation in Stratified Flow of Two Immiscible Liquids Using Hybrid-type Fourier Series

  • Kim, Bong Seok;Choi, Bong-Yeol;Kim, Kyung Youn
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.463-470
    • /
    • 2014
  • In stratified flows of two immiscible liquids, due to the vibration in a pipe, the shape of the interface is not always periodic and it causes the different end points of the interfacial boundary. In this case the performance is not good. To solve this, in this paper, the hybrid-type Fourier series is proposed, which consists of both the polynomial and the trigonometric terms. Under the stationary interfacial boundary during acquiring a full set of voltage data, the performance of the proposed method is evaluated through the numerical experiments. The results show that the proposed method performs better than the conventional Fourier series in estimating the interfacial boundary.

하수처리수이용 흡수식냉동사이클의 해석 (Analysis of Absorption Refrigeration Cycles to Utilize Treated Sewage)

  • 이용화
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.288-298
    • /
    • 1996
  • The gas-fired absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cycles with parallel or series flow type has been performed. The working fluid is Lithium Bromide and water solution. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The efficiency of a couple of cycles has been studied and simulation results show that higher coefficient of performance could be obtained for parallel flow type. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficent of performance in the paralledl flow type.

  • PDF

연초과치 계열의 홍수빈도 분석에 관한 연구 -금강유역을 중심으로- (Study on the flood frequency analysis for the annual exceedance series -Centering along the Geum River basin-)

  • 박영근;이순혁
    • 한국농공학회지
    • /
    • 제24권1호
    • /
    • pp.53-62
    • /
    • 1982
  • This study was attempted to find best fitted distribution and the equations for probable maximum flow with the evaluation of parameters by the method of moment for the rat- ional design of hydraulic structures in the annual exceedance series. Six subwatersheds were selected as studying basins along Geum River basin. The results obtained through this study were analyzed and summarized as follows. 1. Fitted probability distribution was showed in the order of Three Parameter Lognorm al, Type 1 Extremal, Exponential, Pearson Type III, and Log Pearson Type I distribu- tion as the results of x$^2$ goodness of fit test. 2. Kolmogorov-Smirnov test showed in the order of Three Parameter Lognormal, Exp- onential' Pearson Type III, Log Pearson Type III and Type 1 Extremal distribution for the fitted probability distribution. 3. It can be concluded that Three parameter Lognormal distribution is a best fitted one among some other distributions out of respect for each both tests. An Exponential distribution was proposed as a suitable one by Chow, V.T. showeci lower fittness than that of Three Parameter Lognormal in Geum River basin. 5. Probable flood flow equations followins the return periods for each station were obt- ained by Three Parameter Lognormal distribution. 6. It is urgently essential that best fitted probability distribution should be established for the annual exceedance series in the main river systems of Korea.

  • PDF

역타공법 적용을 위한 콘크리트 경시변화 특성 연구 (A Study of Elapsed Time Change on Concrete for Top-Down Method)

  • 정근호;이종균;박선길;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.487-492
    • /
    • 1999
  • The purpose of this study to find the mixture of concrete for Top-Down method. Throughout test of elapsed time change and L-type flow, it was proposed basic performance and level of top-down method concrete. When change as to elapsed time is considered, so series of F10 added 10% S.P satisfied slump and demanded flow (60$\pm$5cm), and L-type slump, L-type flow satisfied liquidity, it can be considered basic mixture of designed actual frame later.

  • PDF

시계열분석과 요인분석에 의한 결정질 암반의 지하수 유동 평가 (Evaluation of Goundwater Flow Pattern at the Site of Crystalline Rock using Time Series and Factor Analyses)

  • 이정환;정해룡;윤시태;김지연;조성일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권4호
    • /
    • pp.12-22
    • /
    • 2014
  • This study evaluated the pattern of groundwater fluctuation in cyrstalline rock using time series and factor analyses. From the results, groundwater level for the 18 wells was classified into 4 types reflecting the hydrogeological properties and rainfall event. Type 1 (DB1-5, DB1-6, DB2-2, KB-10, KB-13) was significantly influenced by groundwater flow through water-conducting features, whereas type 2 (DB1-3, DB1-7, KB-1~KB-3, KB-7, KB-11, KB-14, KB-15) was affected by minor fracture network as well as rainfall event. Type 3 (DB1-1, DB1-2) was mainly influenced by surface infiltration of rainfall event. Type 4 (DB1-8, KB-9) was reflected by the irregular variation of groundwater level caused by anisotropy and heterogeneity of crystalline rock.

월유하량(月流下量)의 추계학적(推計學的) 모의발생자료(模擬發生資料)를 사용(使用)한 저수지(貯水池) 활용(活用) 저수용량(貯水容量)의 확률론적(確率論的) 결정(決定) (A Probabilistic Determination of the Active Storage Capacity of A Reservoir Using the Monthly Streamflows Generated by Stochastic Models)

  • 윤용남;윤강훈
    • 대한토목학회논문집
    • /
    • 제6권3호
    • /
    • pp.63-74
    • /
    • 1986
  • 댐 지점(地點)에서의 저유량(抵流量)의 지속기간(持續期間)과 재현기간(再現期間)을 고려하여 저수지(貯水池)의 활용(活用) 저수용량(貯水容量)을 확률론적(確率論的)으로 결정하는 방법(方法)을 제안하였다. 확률론적(確率論的) 분석(分析)의 신뢰도를 제고시키기 위해 월유량(月流量) 자료계별(資料系別)의 모의발생(模擬發生)에 흔히 사용되는 모의모형(模擬模型) 중 Monte Carlo 모형(模型)과 Thomas Fiering 모형(模型)의 적합성(適合性)을 비교 검토하였으며 그 결과 월유량(月流量) 자료계열(資料系列)을 표준화(標準化)한 계열월유량자료(系列月流量資料)를 근거로 하는 Monte Carlo 모형(模型)(Monte Carlo-B)이 최적모형(最適模型)으로 선정되었다. Monte Carlo-Bah 모형(模型)에 의해 홍천(洪川)댐 지점(地點)에 대한 200 년간(年間)의 월유량계열(月流量系列)을 발생시켰으며 이로 부터 각종(各種) 지속기간별(持續期間別) 저유하량(抵流下量) 계열(系列)을 작성하였다. 여러 크기의 용수수요(用水需要)를 표시하는 상시유량(常時流量)에 대하여 지속기간별(持續期間別) 저유하량(抵流下量) 계열(系列)의 누가용적해석(累加容積解析)을 실시함으로서 활용저수용량(活用貯水容量)-상시유량(常時流量)-재현기간(再現期間)(Active Storage Draft Recurrence Interval) 관계가 수립되었으며 이 관계(關係)는 조발재현기간별(早魃再現期間別)로 용수수요(用水需要)를 보장할 수 있는 저수지(貯水池)의 활용용량(活用容量)을 결정하는 기준(基準)을 제공하게 된다. 또한, 이 관계(關係)를 사용하여 저수지(貯水池)의 설계재현기간별(設計再現期間別) 만수위(滿水位) 표고별(標高別) 상시가용수량(常時可用水量)을 추정하는 방법(方法)과 특정(特定) 저수지(貯水池)의 용수공급능력(用水供給能力)을 평가(評價)하는 방법(方法)을 예시(例示)하였다.

  • PDF

냉각수 공급방식 및 국부적인 물통로의 형상 변화에 따른 냉각수 유동특성 및 연소실 벽면의 냉각효과 (Coolant Flow Characteristics and Cooling Effects in the Cylinder Head with Coolant Flow System and Local Water Passage)

  • 위신환;민영대;이종태
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.32-41
    • /
    • 2003
  • For the countermeasure of expected higher thermal load in miller cycle engine, coolant flows in the cylinder head of base engine with several coolant flow methods and drilled hole passages were measured by using PIV technique. And the cooling effect was evaluated by measurements of wall temperatures according to each coolant flow method. It was found that the series flow system was most suitable among the discussed 3 types of coolant flow methods since it had the best cooling effect in cylinder head by the fastest coolant flow velocity It was also found that for drilled water passage to decrease the large thermal load in exhaust valve bridge, nozzle type is more effective compared with round type of water passage, and its size has to be determined according to the coolant flow pattern and velocity in each cylinder.