• Title/Summary/Keyword: Series-Parallel

Search Result 968, Processing Time 0.032 seconds

Frequency Adjustable Dual Composite Right/Left Handed Transmission Lines (주파수 가변성을 갖는 D-CRLH 전송 선로)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1375-1382
    • /
    • 2008
  • Frequency adjustable D-CRLH(dual-composite right/left handed) transmission lines, which solve the problem of design complexity and uncontrolled frequency of the existing structures, are proposed in this paper. The first design(type I), consisting of defected ground structure(DGS), island pattern in DGS, fixed stub and varactor diodes, controls $C_L$ in the parallel resonant circuit, while the second structure(type 2) composed of fixed DGS, shunt stub and diode adjusts $C_R$ in the series resonant circuit. The dual band frequency points which correspond to the meaningful electrical length of +/-90 degree in the RH/LH region are adjustable according to the bias voltage. The measurement shows that the LH frequency point which has -90 degree of electrical length are adjusted over $4.22{\sim}5.39\;GHz$ and $4.21{\sim}5.05\;GHz$ for type 1 and type 2, respectively, under $1{\sim}12\;V$ of bias voltage. In addition, the frequency Woo where RH turns over LH is controled over $3.26{\sim}4.22\;GHz$ for type 2 with the same bias condition.

Design of a Microwave Bias-Tee Using Lumped Elements with a Wideband Characteristic for a High Power Amplifier (광대역 특성을 갖는 집중 소자를 이용한 고출력 증폭기용 마이크로파 바이어스-티의 설계)

  • Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.683-693
    • /
    • 2011
  • In this paper, a design of high current and broad-band microwave bias-tee was presented for a stable bias of a high power amplifier. An input impedance of bias-tee should be shown to 50 ohm with the wideband in order to be stably-biased the amplifier. For this design of the bias-tee, a capacitor of bias-tee for a DC block was designed with a high wide-band admittance by a parallel sum of capacitors, and a inductor for a RF choke and a DC feeding was designed with a high wide-band impedance by a series sum of inductors. As this inductor and capacitor for the sum has each SRF, band-limitation of lumped element was driven from SRF. This limitation was overcome by control of a resonance's quality factor with adding a resistor. 1608 SMD chips for design's element was mounted on the this pattern for the designed bias-tee. The fabricated bias-tee presented 10 dB of return loss and wide-band about 50 ohm input impedance at 10 MHz~10 GHz.

Studies on Vegetation for Ecological Restoration of Salt Marshes in Saemangeum Reclaimed Land - Population Formation Strategies of Halophytes - (새만금 간척지일대 염습지 생태복원을 위한 식생학적 연구 -염생식물의 개체군 형성 전략-)

  • Kim, Chang-Hwan
    • Journal of Environmental Science International
    • /
    • v.18 no.4
    • /
    • pp.463-471
    • /
    • 2009
  • A study on vegetation in the Mangyeong River and Dongjin River basins and the surrounding regions of the Saemangeum Reclaimed Land was conducted in a series of efforts to determine the expected ecological changes in the salt marshes, to restore their vegetation, to explore the restoring force of halophyte, to examine the community mechanism and, ultimately, to rehabilitate marshy land vegetation along the lakeside, coastal dune and salt marshes of the Saemangeum Project Area. The findings of the study may be summed up as follows: Five species such as Suaeda japonica, Salicornia herbacea, Atriplex gmelini, Aster tripolium and Suaeda asparagoides that are mostly distributed in the estuary of the Saemangeum Reclaimed Land were analyzed to examine the mechanism of halophyte to maintain their community. To find out the strategies of plants for survival and the cause of forming community structure, a research was made as for appearance ratio of biomass, root lengths and germination. With regard to biomasses of halophyte, the biomass of Suaeda japonica increases rapidly, while Salicornia herbacea adopts a strategy of unstable growth pattern by which the biomass increases slowly in parallel with its slow speed of growth since initial appearance of young sapling. In contrast, Suaeda asparagoides, Atriplex gmelini and Aster tripolium choose to adapt themselves to environment promptly by being transformed into life form of annual or biennial plant, a pattern that is presumed to be favorable and stable for survival in the later stage of growth. In short, there is a sharp distinction among the 5 species: i.e. Suaeda japonica that begins to grow fast in the length of surface and underground section but slows down from the mid-stage on; Salicornia herbacea that grows slowly in the beginning step but starts to step up from the middle onward; Atriplex gmelini and Aster tripolium growing slowly in the initial stage but fast later on; and Suaeda asparagoides that turns from the constant growth in the beginning to rapid growth in the later period. The outcomes of the analysis into status of growth and influencing factors of Suaeda japonica in the sowing field that is most widely prevalent in the Saemangeum Reclaimed Land as a sort of ecological pioneer in the salt marshes showed that the average size of grass lands, density and number of individuals increase in the natural sowing field as well as in the plowing field regardless of their physical as well as physico-chemical features of the soil as the season progresses from June to October of a year.

The Fault Current Limiting Characteristics According to Increase of Voltage in a Flux-Lock Type High-Tc Superconducting Fault Current Limiter (전압 증가에 따른 자속구속형 고온 초전도 전류제한기의 사고전류 제한 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Choi, Hyo-Sang;Hyun, Ok-Bae;Hwang, Jong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.93-96
    • /
    • 2004
  • In this paper, we analyzed the current limiting characteristics according to increase of source voltage in the flux-lock type high-Tc superconducting fault current limiter (SFCL). The flux-lock type SFCL consisted of two coils, which were wound in parallel each other through an iron core, and high-Tc superconducting (HTSC) element connected with coil 2 in series. The flux-lock type SFCL has the characteristics better in comparison with the resistive type SFCL because the fault current in the flux-lock type SFCL can be divided into two coils by the inductance ratio of coil 1 and coil 2. The fault current limiting operation of the flux-lock type SFCL can be different due to winding direction of the two coils. The winding method where the decrease of linkage flux between two coils in the accident happens is called the subtractive polarity winding and the winding method in case of the increase of linkage flux is called the additive polarity winding. The fault current limiting experiments according to the source voltage were performed for these two winding methods. Through the comparison and the analysis of the experimental data, we confirmed that the quench time was shorter, irrespective of the winding direction as the source voltage increased and that the fault current and the HTSC's resistance increased as the amplitude of the source voltage increased. The additive polarity winding made the fast quench time and the lower resistance of HTSC element in comparison with the subtractive polarity winding. The fault current of the subtractive polarity winding was larger than that of the additive polarity winding. In conclusion, we found that the additive polarity winding reduced the burden of SFCL because the quench time was shorter and the fault current was smaller than those of the subtractive polarity winding.

  • PDF

Design Method for Cast-in-place Energy Pile Considering Equivalent Heat Exchange Rate (등가열교환율을 적용한 현장타설 에너지파일 설계법)

  • Min, Sunhong;Park, Sangwoo;Jung, Kyoungsik;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1049-1061
    • /
    • 2013
  • In this paper, a relative heat exchange rate is numerically compared for cast-in-place concrete energy piles with different heat exchange pipe configurations, and a new design method for energy piles is proposed. An equivalent heat exchange rate was estimated for the W-type (one series loop), multiple U-type (four parallel loops), and coil-type heat exchanger installed in the same large-diameter drilled shaft. In order to simulate a cooling operation in summer by a CFD analysis, the LWT (leaving water temperature) into a energy pile was fixed at $35^{\circ}C$ and then the EWT (entering water temperature) into a heat pump was monitored. In case of continuously applying the artificial maximum cooling load for 100 hours, all of the three types of heat exchangers show the marginally similar heat exchange rate. However, in case of intermittently applying the cooling load with a cycle of 8 hours operation-16 hours off for 7 consecutive days, the coil type heat exchanger exhibits a heat exchange rate only 86 % of the multiple U-type due to measurable thermal interference between pipe loops in the energy pile. On the other hand, the W-type possesses the similar heat exchange rate to the multiple U-type. The equivalent heat exchange rates for each configuration of heat exchangers obtained from the CFD analysis were adopted for implementing the commercial design program (PILESIM2). Finally, a design method for cast-in-place concrete energy piles is proposed along with a design chart in consideration of typical design factors.

Effects of Inter-Vehicle Information Propagation on Chain Collision Accidents (차량간 정보전파의 연쇄추돌 교통사고에 대한 효과)

  • Chang, Hyun-ho;Yoon, Byoung-jo;Jeong, So-Yeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.303-310
    • /
    • 2018
  • One of most shocking headlines is a serious chain collision accident (CCA). The development of CCA has a temporal and spatial locality, and the information of the CCA is time-critical. Due to these characteristics of CCA, traffic accident information should be rapidly propagated to drivers in order to reduce chain collisions, right after the first accident occurs. Inter-vehicle communication (IVC) based on ad-hoc communication is one of promising alternatives for locally urgent information propagation. Despite this potential of IVC, research for the effects of IVC on the reduction of CCA has not been reported so far. Therefore, this study develops the parallel platform of microscopic vehicle and IVC communication simulators and then analyses the effects of IVC on the reduction of the second collision related to a series of vehicles. To demonstrate the potential of the IVC-based propagation of urgent traffic accident information for the reduction of CCA, the reduction of approaching-vehicle speed, the propagation speed of accident information, and then the reduction of CCA were analysed, respectively, according to scenarios of combination of market rates and traffic volumes. The analysis results showed that CCA can be effectively reduced to 40~60% and 80~82% at the penetration rates of 10% and 50%, respectively.

Morphology and petrology of Jisagae columnar joint on the Daepodong basalt in Jeju Island, Korea (제주도 대포동현무암에 발달한 지삿개 주상절리의 형태학 및 암석학적 연구)

  • Koh Jeong-Seon;Yun Sung-Hyo;Hong Hyun-Chu
    • The Journal of the Petrological Society of Korea
    • /
    • v.14 no.4 s.42
    • /
    • pp.212-225
    • /
    • 2005
  • This study has been designed to elucidate the morphology of Jisagae columnar joints and the petrography and petrochemistry of Daepodong basalt in Jeju Island, distributed along the 3.5 km-long coast from Seongcheonpo to Weolpyeongdong. Colonnade of the Jisagae columnar joint typically occurs within the upper part of a flow and consists of relatively well-formed basalt columns. Most columns are straight with parallel sides and diameters from 100 cm to 205 cm, $130\~139\;cm$ in maximum. Length of the columns extends up to 20 m. Most columns tend to have 6 or 5 sides but sometimes they have as few as $3\~4$ or as many as 7 or 8 sides. The Daepodong basalt consists of plagioclase, olivine, orthopyroxene, clinopyroxene, ilmenite and magnetite. Plagioclase is labradorite, clinopyroxene is augite, orthopyroxene is bronzite and olivine is chrysolite and hyalosiderite. The Daepodong basalt shows porphyritic texture with matrix of mainly intersetal texture. The Daepodong basalt is plotted into alkali rock series on the TAS diagram. The tectonic setting of the Daepodong basalt represents within plate environment.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

A fundamental study on the installation methods of automatic identification buoy on coastal gill net (연안자망 부이에 어구자동식별 장치 설치방안에 관한 기초적 연구)

  • HEO, Nam-Hee;KANG, Kyoung-Bum;KOO, Myeong-Seong;KIM, Keun-Hyong;KIM, Jong-Bum;JWA, Min-Seok;KIM, Jun-Teck;JOUNG, Joo-Myeong;KIM, Byung-Yeob;KIM, Suk-Jong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.4
    • /
    • pp.294-302
    • /
    • 2019
  • As a series of fundamental researches on the development of an automatic identification monitoring system for fishing gear. Firstly, the study on the installation method of automated identification buoy for the coastal improvement net fishing net with many loss problems on the west coast was carried out. Secondly, the study was conducted find out how to install an automatic identification buoy for coastal gill net which has the highest loss rate among the fisheries. GPS for fishing was used six times in the coastal waters around Seogwipo city in Jeju Island to determine the developmental status and underwater behavior to conduct a field survey. Next, a questionnaire was administered in parallel on the type of loss and the quantity and location of fishing gear to be developed and the water transmitter. In the field experiment, the data collection was possible from a minimum of 13 hours, ten minutes to a maximum of 20 hours and ten minutes using GPS, identifying the development status and underwater behavior of the coastal gillnet fishing gear. The result of the survey showed that the loss of coastal net fishing gear was in the following order: net (27.3%), full fishing gear (24.2%), buoys, and anchors (18.2%). The causes were active algae (50.0%), fish catches (33.3%) and natural disasters (12.5%). To solve this problem, the installation method is to attach one and two electronic buoys to top of each end of the fishing gear, and one underwater transmitter at both ends of the float line connected to the anchor. By identifying and managing abnormal conditions such as damage or loss of fishing gear due to external factors such as potent algae and cutting of fishing gear, loss of fishing gear can be reduced. If the lost fishing gear is found, it will be efficiently collected.

Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions (자속구속형 초전도 전류제한기의 철심조건에 따른 특성)

  • Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Cho, Guem-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.38-45
    • /
    • 2006
  • The superconducting fault current limiters(SFCLs) provide the effect such as enhancement in power system reliability due to limiting the fault current within a few miliseconds. Among various SFCLs we have developed a flux-lock type SFCL and exploited a special design to effectively reduce the fault current according to properly adjustable magnetic field after the short-circuit test. This SFCL consists of two copper coils wound in parallel on the same iron core and a component using the YBCO thin film connected in series to the secondary copper coil. Meanwhile, operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. To analyze the operational characteristics, we compared closed-loop with open-loop iron core. When the applied voltage was 200[Vrms] in the additive polarity winding, the peak values of the line current the increased up to 30.71[A] in the closed-loop and 32.01[A] in the open-loop iron core, respectively. On the other hand, in the voltages generated at current limiting elements were 220.14[V] in the closed-loop and 142.73[V] in the opal-loop iron core during first-half cycle after fault instant under the same conditions. We confirmed that the open-loop iron core had lower power burden than in the closed-loop iron core. Consequently, we found that the structure of iron core enabled the flux-lock type SFCL at power system to have the flexibility.