• Title/Summary/Keyword: Series resonant filter

Search Result 32, Processing Time 0.032 seconds

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Design of BPF Using A New DGS Resonator (새로운 DGS공진기를 이용한 대역통과 여파기의 설계)

  • Yoon Jang-Sik;Joung Myoung-Sub;Park Jun-Seok;Park Cheon-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.91-96
    • /
    • 2005
  • In this letter, we proposed a novel DGS (Defected Ground Structure) microstrip resonator. The proposed DGS resonator has the resonant and anti-resonant characteristic that is very similar to those of a SAW resonator or a FBAR. In order to confirm the validity of the proposed resonator, we designed and implemented bandpass fitters by using series ana parallel resonators.

Design of Input Output Filter of Uninterruptible Power Supply (무정전전원장치(UPS)의 입출력필터설계에 관한 연구)

  • Kim, Je-Hong;Cho, Yang-Heang;Son, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.132-135
    • /
    • 2005
  • A design for the input filter and the output filter of a single-phase uninterruptible power supply (UPS) system is proposed. A filter design example is presented. And also, this dissertation describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Performance Analysis of ARCP Inverter for Power System Interconnection (ARCP(Auxiliary Resonant Commutated Pole) 인버터의 특성분석)

  • Ha, Yo-Chul;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon;Kim, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1065-1067
    • /
    • 2000
  • This paper describes performance analysis of ARCP Inverter, which can offer zero voltage switching at nominal voltage stress. The system consists of a voltage-source inverter with sort-switching module. Each main switch is connected in parallel with resonant capacitor and two auxiliary switches are placed in series with a resonant reactor for soft-switching capability. The described ARCP inverter could be effectively applied for active power filter reactive power compensator, and UPS.

  • PDF

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Analysis and Design of a Multi-resonant Converter with a Wide Output Voltage Range for EV Charger Applications

  • Sun, Wenjin;Jin, Xiang;Zhang, Li;Hu, Haibing;Xing, Yan
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.849-859
    • /
    • 2017
  • This paper illustrates the analysis and design of a multi-resonant converter applied to an electric vehicle (EV) charger. Thanks to the notch resonant characteristic, the multi-resonant converter achieve soft switching and operate with a narrowed switching frequency range even with a wide output voltage range. These advantages make it suitable for battery charging applications. With two more resonant elements, the design of the chosen converter is more complex than the conventional LLC resonant converter. However, there is not a distinct design outline for the multi-resonant converters in existing articles. According to the analysis in this paper, the normalized notch frequency $f_{r2n}$ and the second series resonant frequency $f_{r3n}$ are more sensitive to the notch capacitor ratio q than the notch inductor ratio k. Then resonant capacitors should be well-designed before the other resonant elements. The peak gain of the converter depends mainly on the magnetizing inductor ratio $L_n$ and the normalized load Q. And it requires a smaller $L_n$ and Q to provide a sufficient voltage gain $M_{max}$ at ($V_{o\_max}$, $P_{o\_max}$). However, the primary current increases with $(L_nQ)^{-1}$, and results in a low efficiency. Then a detailed design procedure for the multi-resonant converter has been provided. A 3.3kW prototype with an output voltage range of 50V to 500V dc and a peak efficiency of 97.3 % is built to verify the design and effectiveness of the converter.

A Study on LLCL Filter to Reduce Harmonic Current of Grid Connected Power Inverter (계통연계형 인버터의 고조파 전류저감을 위한 LLCL 필터에 관한 연구)

  • An, Byoung-Woong;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • In this paper, the new LLCL filter is proposed for grid connected three-phase PWM inverter for passive damping. LLCL filter inserts a small inductor in the branch of the capacitor of the traditional LCL filter to compose a series resonant circuit to reduce the switching-frequency component on grid current. Using LLCL filter, the switching-frequency current ripple components can be attenuated much better than the LCL filter, leading to a decrease in the total inductance. However, the resonance phenomena caused by zero impedance from the addition of LC branch in LLCL filter can be a big problem. Resonance phenomena of LLCL filter can be a source of grid system instability, so proper damping methods are required. However, it is difficult to apply a passive damping method in the conventional LLCL filter, because the damping resistor increase impedance of the LC branch. Therefore, switching frequency component of grid current can not much attenuated by low Q of LC series resonance effect. In this paper, a new LLCL filter is proposed to overcome the conventional LLCL filter with passive damping. The validity of the proposed method is proven by simulation and experimental result.

A Study on the Simulation of a Triple Laminated Piezoelectric Ceramic Filter (3중 적층형 압전세라믹 필터의 Simulation에 관한 연구)

  • Kim, Jung-Hyun;Han, Deuk-Young;Nam, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.850-853
    • /
    • 1991
  • This paper suggests a triple laminated piezoelectric ceramic filter composed of three piezoelectric ceramic vibrators and two sheets of thin insulator, and an equivalent circuit of the filter and several expressions for the resonant frequency; voltage, current, and power gains under the various loads and frequencies; and phase differences between the input and the output voltages are introduced and simulated from its equivalent circuit when two outputs from the side vibrators are connected in series. Those expressions show that this filter has not only a filtering function but also an amplifying function.

  • PDF

A Fuzzy Self-Tuning PID Controller with a Derivative Filter for Power Control in Induction Heating Systems

  • Chakrabarti, Arijit;Chakraborty, Avijit;Sadhu, Pradip Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1577-1586
    • /
    • 2017
  • The Proportional-Integral-Derivative (PID) controller is still the most widespread control strategy in the industry. PID controllers have gained popularity due to their simplicity, better control performance and excellent robustness to uncertainties. This paper presents the optimal tuning of a PID controller for domestic induction heating systems with a series resonant inverter for controlling the induction heating power. The objective is to design a stable and superior control system by tuning the PID controller with a derivative filter (PIDF) through Fuzzy logic. The paper also compares the performance of the Fuzzy PIDF controller with that of a Ziegler-Nichols PID controller and a fine-tuned PID controller with a derivative filter. The system modeling and controllers are simulated in MATLAB/SIMULINK. The results obtained show the effectiveness and superiority of the proposed Fuzzy PID controller with a derivative filter.

Contactless feed-back control method through power stage transformer in non-contact battery charger (무접점 충전기의 전력단 변압기를 통한 무접점 피드백 제어방식)

  • 김창균
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.258-261
    • /
    • 2000
  • A non-contact battery charger which transfers energy using magnetic field has a difficulty with a feed-back control due to the interaction between the power and signal processing This paper proposes an effective method which uses auxiliary windings of transformer as signal path and copes with cross-talk using the MOSFET ringing phenomenon and ceramic filter. The power stage is half-bridge series resonant converter. Design procedure and experimental verification are presented.

  • PDF