• Title/Summary/Keyword: Series Operation

Search Result 1,271, Processing Time 0.03 seconds

Complications after Senning Operation for TGA with and Wothout VSD (대혈관전위증에서 Senning수술후 합병증에 관한 임상적 고찰)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.595-603
    • /
    • 1993
  • We analysed 60 consecutive patients who got Senning operation for transposition of the great arteries [TGA] with or without ventricular septal defects [VSD]. There were 41 simple TGA [group I] and 19 TGA with VSD [Group II], the operative mortality was 20 % [in group I 4.9 %, group II 52.6 %]. Among the survivors [n=48], the mean follow-up period was 7 years [range, 1 year to 13.5 years] and the actuarial survival rate at 13 years were 95 % in group I and 42 % in group II. Preoperative high left ventricular pressure and high pulmonary arterial pressure affected the surviving [p<0.01]. There occurred various type of arrhythmia like junctional rhythm, first degree atrioventricular [AV] block, sick sinus syndrome and complete AV block, and we inserted 2 permanent pacemakers for these patients. The incidence of arrhythmia were 28.2 % [11/39] in group I and 55.6 % [5/9] in group II, and the actuarial freedom from arrhythmia at 13 years after operation was 66 % [71 % in group I, 44 % in group II]. Increased aortic cross clamping time had affected the development of arrhythmia [p<0.05] which meant the complexity of the operation. The total incidence of left ventricular outflow tract obstruction [LVOTO] was 31.3 % [15/48], but only 3 patients [6.25 %] showed the significant gradient requiring reoperation. The pulmonary venous pathway obstruction [PVO] were found in 3 patients, all in group I, and among them only one required the reoperation. The estimated freedom from PVO was 89 % at 13 years [87 % in group I, 100 % in group II], but we couldn`t find any significant systemic venous obstruction in our series. There occurred 27.1 % [13/48] mild degree tricuspid valve regurgitation without necessary surgical correction. We experienced 14.6 % [7/48] reoperation rate: 3 residual VSD, 3 LVOTO, 1 PVO, 3 atrial baffle leakage. For this high incidence of complication rate after Senning operation and high mortality in TGA with VSD, We do not use this kind of surgical modality any more and do the Jatene operation for all the TGA patients since several years ago.

  • PDF

Development of AR System for Asphalt Pavement Compaction Operation and Suggestion for Accompanying Education Program (AR을 이용한 아스팔트 포장 다짐공사 지원 시스템 구축 및 교육과정 제안)

  • Kim, Namho;Cho, Namjun;Kim, Noah
    • Journal of Practical Engineering Education
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • A pavement construction process consists of series of lay-down operation for pavement materials to form a designated thickness and compaction operation for the lay-down layer to form a designated strength. A technological breakthrough in pavement compaction equipment was made in last 15 years in western countries: intelligent compaction roller, that is equipped with GPS along with other pavement response sensors is becoming a game-changer in pavement construction. This paper introduces AR system that may be used in asphalt pavement compaction operation using intelligent compactor. Since AR technology is very new concept in road construction society, a suggestion for accompanying education program was also made for specific task group in pavement compaction operation. Since AR technology has not been introduced in asphalt pavement compaction operation, the AR compaction management would lead the construction quality of asphalt pavement to the beyond level.

Circuit Design and Performance Analysis of CCFL Dimming Controller With Frequency Modulation

  • Kim, Cherl-Jin;Ji, Jae-Geun;Yoon, Shin-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.201-205
    • /
    • 2004
  • The CCFL dimming control methods are generally used lamp current regulation or average current adjustment method feeding the CCFL inverter. Inverter operation frequency is higher than resonant frequency for safe operation. In this study, we design the half-bridge type series and parallel resonant converter circuit that switches at variable frequency modulation methods to control the output power. This method has advantages such as low EMI and reduced harmonics, and it is convenient for dimming control using a microprocessor. The validity of this study is confirmed from the simulation and experimental results.

The Operation Characteristics of Hybrid Supercapacitor Module for LED Emergency Luminaires (LED 비상 유도등을 위한 하이브리드 슈퍼커패시터 모듈의 동작 특성)

  • Mang, Ju-Cheul;Yoon, Jung-Rag
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.473-479
    • /
    • 2015
  • Hybrid supercapacitors with high power density and long cycle life are widely used for emergency power source of LED emergency luminaires. In this paper, we designed and fabricated a hybrid capacitor cell and a module for the LED emergency luminaires. Using hybrid supercapacitor cells (1,000 F, 2.8 V), we designed a module in a 10-year warranty considering aging and ESR. Considering the ESR and efficiency has been designed to module with 1,000 F 5.6 V design results in 2 series and 2 parallel combination. Module was used to confirm that the operation 77.5 minutes at room temperature, discharge LED emergency luminaires with 2 W. As a LED emergency luminaires of emergency power supply that we can support more than 10 years of life was confirmed the applicability of hybrid supercapacitor.

Design of High Voltage Switch for Pulse Discharging (펄스 방전을 위한 고전압 스위치 설계)

  • Nimo, Appiah Gideon;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.361-362
    • /
    • 2016
  • Presented in this paper is the design of a high voltage switch module made up of MOSFETs, pulse transformers and their gate driver circuits compactly fitted onto a single PCB module. The ease by which the switch modules can be configured (series stacking and/or parallel stacking) to meet future load variations allows for flexible operation of this design. In addition, the detailed implementation of the gate driver circuit for reliable and easier switch synchronization is also described in this paper. The stored energy in the capacitor bank of a 15kV, 4.5kJ/s peak power capacitor charger was discharged using the developed high voltage switch, and by experimental results, the operation of the proposed circuit was verified to be effectively used as a switch for pulse discharging.

  • PDF

Driving Characteristic of Passive Converter for Single Phase SRM (단상 SRM 구동을 위한 Passive Converter 동작특성)

  • Liang, Jianing;Seok, Seung-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.113-115
    • /
    • 2008
  • At the high speed operation, the high demagnetization voltage can reduce the negative torque, so the output power and efficiency can be improved. In this paper, a novel power converter for single phase SRM with high demagnetization voltage is proposed. A simple passive capacitor circuit is added in the front-end, which consists of three diodes and one capacitor. Based on this passive network, the two capacitors can be connected in series and parallel, so the phase winding of SRM obtains general do-link voltage in excitation mode and the double dc-link voltage in demagnetization mode. The operation modes of the proposed converter are analyzed in detail. Some computer simulation results is done to verify the performance of proposed converter.

  • PDF

A Pulsed Mode Operating DC Power Supply Based on Modified Multilevel Converter (Modified 멀티레벨 컨버터 기반 펄스모드 동작 직류전원장치)

  • Ahn J.S.;Nho E.C.;Kim I.D.;Kim H.G.;Chun T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.264-268
    • /
    • 2003
  • This paper describes a high voltage high power DC power supply which has the ability of pulsed mode operation. The power supply Is constructed with several series connected power converters based on modified multilevel converters. The modified multilevel converters are suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis, simulations, and experiments are carried out to Investigate the operation and usefulness of the proposed scheme.

  • PDF

A study on the behaviors of chatter in milling operation (밀링가공시의 채터현상 연구)

  • Kim, Y.K.;Yoon, M.C.;Ha, M.K.;Sim, S.B.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.1 no.1
    • /
    • pp.123-132
    • /
    • 2002
  • In this study, the static and dynamic characteristics of endmilling process was modelled and the analytic realization of chatter mechanism was discussed. In this regard, We have discussed on the comparative assessment of recursive time series modeling algorithms that can represent the machining process and detect the abnormal machining behaviors in precision endmilling operation. In this study, simulation and experimental work were performed to show the malfunctional behaviors. For this purpose, new recursive least square method (RLSM) were adopted for the on-line system identification and monitoring of a machining process, we can apply these new algorithms in real process for detection of abnormal chatter. Also, The stability lobe of chatter was analysed by varying parameter of cutting dynamices in regenerative chatter mechanics.

  • PDF

CONSTRUCTING DAILY 8KM NDVI DATASET FROM 1982 TO 2000 OVER EURASIA

  • Suzuki Rikie;Kondoh Akihiko
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.18-21
    • /
    • 2005
  • The impact of the interannual climatic variability on the vegetation sensitively appears in the timing of phenological events such as green-up, mature, and senescence. Therefore, an accurate and temporally high-resolution NDVI dataset will be required for analysis on the interannual variability of the climate-vegetation relationship. We constructed a daily 8km NDVI dataset over Eurasia based on the 8km tiled data of Pathfinder A VHRR Land (PAL) Global daily product. Cloud contamination was successfully reduced by Temporal Window Operation (TWO), which is a method to find optimized upper envelop line of the NDVI seasonal change. Based on the daily NDVI time series from 1982 to 2000, an accurate (daily) interannual change of the phenological events will be analyzed.

  • PDF

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.

  • PDF