• Title/Summary/Keyword: Serial test

Search Result 343, Processing Time 0.025 seconds

Characterization of canine coronaviruses isolated from the dogs with diarrhea in Korea (설사증 이환견(犬)으로 부터 분리(分離)한 canine coronavirus의 성상(性狀)에 관한 연구(硏究))

  • Lee, Byung-hyung;Jun, Moo-hyung;Park, Jong-hyeon;Hwang, Eui-kyung;Huh, Won
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.517-527
    • /
    • 1994
  • An attempt was made to isolate a causative viral agents from the fecal specimens of the diseased dogs with the gastroenteritis symptoms. Two coronavirus-like agents were isolated by serial dilution end point method and plaque assay. The isolates were characterized in terms of cytopathology, antigenicity, replication, physicochemical and morphological properties. The results obtained through the experiment were as follows; 1. Among 7 fecal specimens collected from the dogs with enteric disease, 2(28.6%)coronavirus-like agents showing typical cytopathic effects of canine coronavirus were isolated, and designated as CCV D1 and CCV D2, respectively. 2. By the cross-neutralization test and indirect immunofluoresence antibody test, the isolates were antigenically indentified as the standard CCV. The viruses were replicated only in the cytoplasm of A-72 cells. 3. The isolates showed no haemagglutinating activity against the erythrocytes from 11 kinds of animals. 4. The electron microscopic observation for the isolates showed spherical and pleomorphic features, covered with club-shaped projections on the surface. The size of particles was ranged from 70 to 150nm. 5. In one-step growth curve for the isolates in A-72 cells, maximum titers of intracellular vius was $10^{4.6}$ $TCID_{50}/0.1ml$ at 46 hrs postinoculation(pi) of CCV Dl and $10^{4.4}$ $TCID_{50}/0.1ml$ at 34 hrs pi of CCV D2. The maximum titers of extracellular virus was $10^{5.5}$ $TCID_{50}/0.1ml$ at 58 hrs pi of CCV D1 and $10^{5.8}$ $TCID_{50}/0.1ml$ at 46 hrs pi of CCV D2. 6. In physicochemical property test, the isolates were very sensitive to choroform and were found to be RNA virus. The viruses was stable at pH 3.0 for 1 hr and at $22{^{\circ}C}$ for 5 hrs. However, infectivity titers reduced remarkably by treatment with $56{^{\circ}C}$ for 10min.

  • PDF

COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS (다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교)

  • Lee, Hyun-A;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.499-506
    • /
    • 2008
  • The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using $PROTAPER^{TM}$ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test wasperformed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05). The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.

Evaluation of Removal Properties of Cu(II) from Aqueous Solutions by Inflated Vermiculites (팽창질석에 의한 수용액내의 구리 제거능 평가)

  • Song, Jaehong;Lee, Junki;Kim, Seogku;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.25-32
    • /
    • 2009
  • The main objective of this study was to examine the removal properties of Cu from water by inflated vermiculites. The component of vermiculites was analyzed by XRF and the concentration of Copper ion was measured by UV-VIS. Serial batch Kinetic tests and batch sorption tests were conducted to determine the removal characteristics for Cu in aqueous solutions. The result shows that removal rate, $K_{obs}$, of Cu are 0.73, 1.52, and 1.71 for initial pH 3, pH 4, pH 5, respectively, and are 3.19, 1.90, and 0.73 for the initial concentration of $1mg\;L^{-1}$, $5mg\;L^{-1}$, $10mg\;L^{-1}$, respectively. It leads to the conclusion that the removal rates are inversely proportional to the initial Cu concentration and are increased proportionally to the initial pHs. Finally, Sorption data were correlated with both Langmuir and Freundlich isotherms. As a result, Langmuir and Freundlich models were well fitted to batch isotherm data with good values of the determination coefficient. but the determination coefficient value for the Freundlich model fit was slightly higher than that of Langmuir model (0.965 for the Freundlich model and 0.936 for the Langmuir model). Using the Langmuir model, the maximum sorption capacity ($Q_{max}$), Freundlich partition coefficient, and the numerical value of n wrer estimated as $1,250mg\;kg^{-1}$, $635.1L\;kg^{-1}$ and 1.69, respectively. These results show that the inflated vermiculites could be used as an excellent adsorbent for copper contained in various types of aqueous solutions.

  • PDF

Study Focused on Task Process regarding Effective Information Transfer of Ancillary Tests in Diagnostic Pathology (병리추가조직검사 정보전달을 위한 업무프로세스 연구)

  • Ko, Jae-Nam;Park, Yun-Ik;Jung, Jin-Gyeong;Ahn, Sang-Ho;Kim, Jae-Ho;Shin, Hwa-Jeong;Hyun, Ji-Suk;Kim, Kyeong-Ho
    • Quality Improvement in Health Care
    • /
    • v.22 no.2
    • /
    • pp.95-108
    • /
    • 2016
  • Purpose: Ancillary tests such as immunohistochemistry or molecular testing for pathologic diagnosis are performed using ready-made tissue blocks for a histological examination. Various methods and processes during ancillary testing cause some of issues, particularly in the time required and the results reporting scheme. Methods: To solve these issues, we constructed real-time management software. When a pathologist or a clinician had ancillary tests examined using this software by selecting the codes of the needed ancillary tests on site and the system assigned the tests to each laboratory. Then, pathology technologists checked the referred tests and performed the examination. In clinical departments, serial number of each ancillary test can be matched the original pathologic ID. In the department of pathology, numbers of tissue blocks that needed additional tests could be indicated and detected using one-click detection system when a clinician referred the test. Results: Using this system resulted in simplifying the referral procedures from nine-steps to three-steps in each clinical department and from seven-steps to two-steps in department of pathology. Errors that happened on the paper-based request system were also reduced. Furthermore, the time required was saved by seven hours in pathologic laboratory on average. Mean durations from requesting to reporting of the ancillary test was reduced by three days for specimens of health promotion center. Conclusion: Construction of an effective information transfer system may be helpful for shortening the time required, reducing errors, and checking processing information of the tests in real time.

Changes in the Prevalence of Biopsy-proven Helicobacter pylori Infection in Korean Children with Functional Recurrent Abdominal Pain Over the Last 18 Years (최근 18년간 한국 소아 Helicobacter pylori 유병률의 변화: 기능성 반복성 복통 소아에서 연도별 내시경 진단 양성률의 감소에 관한 연구)

  • Lee, So-Yeon;Ko, Jae-Sung;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.2
    • /
    • pp.150-155
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate observed changes in the prevalence of biopsy-proven Helicobacter pylori infection in Korean children with functional recurrent abdominal pain during the past 18 years. Methods: Between July 1991 and December 2008, 1,194 children with functional recurrent abdominal pain (499 males and 695 females) 9.2${\pm}$3.1 years of age were included. Upper gastrointestinal endoscopies were performed in all patients. H. pylori infection was assessed by the CLO test. Changes in the prevalence of the endoscopic diagnosis of H. pylori infection during 18 years were analyzed. Results: The prevalence of H. pylori infection between 1991 and 1993, 1994 and 1996, 1997 and 1999, 2000 and 2002, 2003 and 2005, and 2006 and 2008 were 25.1% (56/223), 23.1% (45/195), 19.3% (28/145), 16.1% (39/242), 11.3% (24/213), and 10.8% (19/176), respectively; these serial decreases in the prevalence over 18 years were statistically significant (p<0.001). Regardless of gender and age, the prevalence of H. pylori infection decreased. This decrease was inversely related to socioeconomic improvement as represented by the per capita gross national income growth of Korea. Conclusion: The prevalence of H. pylori infection has decreased significantly for the past 18 years in Korean children. This decrease might be caused by an improvement in socioeconomic status.

  • PDF

A Study on the Adsorptive Removal of Heavy Metals Using Inflated Vermiculites (팽창질석을 이용한 중금속 흡착제거에 관한 연구)

  • Lee, Junki;Koh, Taehoon;Kim, Sukyung;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.61-68
    • /
    • 2009
  • The main objective of this study was to examine the removal of heavy metals from water by inflated vermiculites. The component of vermiculites was analyzed by XRF, and the concentration of metal ion was measured by ICP-AES. Serial batch kinetic tests and batch sorption tests were conducted to determine the removal characteristics for heavy metals in aqueous solutions. As a result, solution pH values of tests with the inflated vermiculites generally increased and then stabilized. Equilibrium pHs were generally established within 5 hrs. In addition, removal rates of inflated vermiculites were tested at the initial concentration of 3 mg/L. As a result, at equilibrium concentration, except for chromium (36.23%), Most of the heavy metals were effectively removed (96.08~98.54%). Finally, sorption data were correlated with both Langmuir and Freundlich isotherms. The Qmax obtained from Langmuir isotherm were determined to Pb $725.4mg\;kg^{-1}$, Cd $568.8mg\;kg^{-1}$, Zn $540.2mg\;kg^{-1}$, Cu $457.2mg\;kg^{-1}$ Cr $0.9mg\;kg^{-1}$ respectively. The results of the study indicate that inflated vermiculites can be properly used as an adsorbent for various heavy metals because of its outstanding removal rate.

  • PDF

Quantitative Evaluation of the Remaining Hepatic Function after Surgery in Patients with Hepatic Cancer using Deconvolution Technique of Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 간암 환자의 수술 후 잔여 간 기능의 정량적 평가)

  • Kim, Deok-Won;Kim, Su-Chan;Yun, Seok-Jin;Lee, Jong-Du;Kim, Byeong-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.301-306
    • /
    • 1997
  • Surgical removal of hepatic cancerous tissues have been widely performed due to its early detection. However, a patient can not survive if excessive hepatic tissues were removed. Therefore, quantitative evaluation of remaining hepatic function after surgery is a really important factor for surgeon. the currently used ICG Rmax and Lidocaine clearance tests have disadvantages such as tedium, complexity, and inability to estimate remaining hepatic function after surgery. While HEF has advantages such as simplicity, quickness, nonivasiveness, and quantification, its reliability has been doubtful. Thus, the program for calculation of HEF has been developed from serial gamma camera image data. And we compared the reliability of HEF with ICG Rmax and Lidocaine clearance test using 6normal and 18 abnormal rabbits with damaged livers. The correlation coefficient of HEF to ICG Rmax and MEGX was 0.91, 0.94, respectively. I was also found that the HEFs of normal and abnormal hepatic tissues was higher than 100% and lower than 80%, respectively. Thus we confirmed that HEF can be a good indicator distinguishing between abnormal tissues and normal ones. Finally, we could conclude that patients would survive if both the pre-and the post-operative HEF were greater than 60%.

  • PDF

Verification of the upper limit of results through dilution tests for RIA test (RIA 검사별 희석실험을 통한 결과의 상한치 검증)

  • LEE, Geun Ui;CHOI, Jin Ju;LEE, Young Ji;YOO, Seon Hee;LEE, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.42-46
    • /
    • 2022
  • Purpose In the meantime, there have been not many samples that require dilution, and it has been difficult for the examiner to set an appropriate dilution multiple for RIA test item and report the results. Accordingly, it was judged that it was necessary to set the maximum dilution multiple for each test and to verify the upper limit of the clinical reportable range. Therefore, in this study, the maximum dilution multiple for each RIA test was set and the upper limit of the clinical reportable range was verified accordingly Materials and Methods Among all RIA tests conducted at Asan Medical Center, the study treated on 30 types of tests which also conduct the dilution test. Data from March to July 2021 were collected and analyzed. The study was conducted on samples subjected to serial dilutions such as X2, X4 or X10, X102, X103, X104, X105. Results Among a total of 30 test types, 18 test types have more than 5 N values in the tolerance range of 80~120%. As a result of the verification of maximum dilution multiples, the test set to 104 is 𝛼-fetoprotein and thyroglobulin, and the test set to 103 is CA-125, CEA, and 𝛽-hCG, and the test set to 102 is Free PSA, PSA, CA15-3, SCC, Ferritin, PTH, Cortisol, and Calcitonin. Tests set to 10 include three categories: 𝛽2-Microglobulin, C-peptide, and Testosterone. Conclusion It is expected that it will contribute to improving the quality of nuclear medicine blood tests as the results of dilution experiments can be reported quickly and accurately through the verification of the clinical reportable range.

Real-time Implementation of the AMR-WB+ Audio Coder using ARM Core(R) (ARM Core(R)를 이용한 AMR-WB+ 오디오 부호화기의 실시간 구현)

  • Won, Yang-Hee;Lee, Hyung-Il;Kang, Sang-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.119-124
    • /
    • 2009
  • In this paper, AMR-WB+ audio coder is implemented, in real-time, using Intel 400MHz Xscale PXA250 with 32bit RISC processor ARM9E-J(R)core. The assembly code for ARM9E-J(R)core is developed through the serial process of C code optimization, cross compile, assembly code manual optimization and adjusting the optimized code to Embedded Visual C++ platform. C code is trimmed on Visual C++ platform. Cross compile and assembly code manual optimization are performed on CodeWarrior with ARM compiler. Through these stages the code for both ARM EVM board and PDA is implemented. The average complexities of the code are 160.75MHz on encoder and 33.05MHz on decoder. In case of static link library(SLL), the required memories are 65.21Kbyte, 32.01Kbyte and 279.81Kbyte on encoder, decoder and common sources, respectively. The implemented coder is evaluated using 16 test vectors given by 3GPP to verify the bit-exactness of the coder.

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF