• 제목/요약/키워드: Sequential Trigger

검색결과 12건 처리시간 0.019초

순차식 촉매연소 시스템 (Sequential Catalytic Combustion System)

  • 유상필;정남조;이승재;류인수;강성규;송광섭
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.197-200
    • /
    • 2004
  • Compared to conventional flame combustion, catalytic combustion had the advantage of oxidation of V.O.C. gas which was high voluminous, low caloric mixture flow. However, the temperature of mixture gas should be over the one of catalytic reaction start and the control of reaction on the catalytic surface tends to be vulnerable. To overcome these obstacles, composition of both catalytic combustor and heat exchanger was devised and named the sequential catalytic combustion system. In this system, only trigger unit needed preheating process for transient starting time. Once trigger unit was ignited, the next unit w3s supplied heat to ignite from that and same process was performed to the last one sequentially. When it come to steady state, whole mixture gas was oxidated at each unit simultaneously and preheating for trigger unit was not needed any more. System of 100 kcalh/hr capacity was devised and operated successfully.

  • PDF

순차식 촉매연소 시스템 (Sequential Catalytic Combustion System)

  • 유상필;송광섭;류인수;정남조
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.153-158
    • /
    • 2003
  • Catalytic Combustion used to be applied to specific conditions because of the characteristics different from flame combustion. However, many researches are focused on widening the applicant range of catalytic combustion with the competences of catalytic combustion. The development of many catalytic combustion appliances is one of the trials to overcome the restrictions of reaction and maximize the merits. In this research, past developments of appliances are depicted and new conceptual system will be introduced - sequential system. Sequential catalytic combustion system is composed of units - existing catalytic heat exchangers. This system is performed with parallel in composition and serially in operation. First, the burden of the preheating can be dramatically reduced. Second, stable operation control is expected. Lastly, Capacity expansion is flexible.

  • PDF

대전류 펄스 성형이 가능한 150MW급 펄스파워 시스템의 설계 및 동작특성 (Design and Operational Characteristics of 150MW Pulse Power System for High Current Pulse Forming Network)

  • 황선묵;권해옥;김종서;김광식
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.217-223
    • /
    • 2012
  • 본 논문은 트리거 시간을 조절하여 펄스 성형이 가능한 150 MW 펄스 파워 시스템의 설계와 동작특성을 알아보았다. 이 시스템은 2개의 커패시터 뱅크 모듈로 구성되어 있고, 각 커패시터 뱅크 모듈은 병렬로 연결되어 있다. 그리고 커패시터 뱅크 모듈은 메인스위치, 커패시터, 에너지 덤프회로, 크로바 회로, 펄스 성형 인덕터로 구성되어 있다. 또한 이 시스템의 모듈 선택과 트리거 시간은 트리거 제어부에서 조정된다. Pspice 시뮬레이션은 실험회로의 결과를 예측하고, 시스템의 구성품의 파라미터를 결정하기 위한 것으로 사용하였다. 실험 결과, 시뮬레이션은 실험결과와 잘 일치하였다. 출력 전류의 펄스폭은 커패시터 뱅크 모듈에서의 순간적 점화 시간 제어로 300~650 us의 펄스폭이 형성되었다. 그리고 최대 전류값은 2개의 커패시터 뱅크 모듈이 동시에 트리거 되었을 때 약 40 kA 정도이다. 이 150 MW 펄스 파워 시스템은 파암 전원, Rail Gun, Coil Gun, 나노분말 제조, HPM 등과 같은 대전류 펄스 파워 시스템에 적용할 수 있다.

클록 게이팅을 이용한 저전력 UART 설계 (A Low Power UART Design by Using Clock-gating)

  • 오태영;송승완;김희석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.865-868
    • /
    • 2005
  • This paper presents a Clock-gating technique that reduces power dissipation of the sequential circuits in the system. The Master Clock of a Clock-gating technique is formed by a quaternary variable. It uses the covering relationship between the triggering transition of the clock and the active cycles of various flip-flops to generate a slave clock for each flip-flop in the circuit. At current RTL designs flip-flop is acted by Master clock's triggering but the Slave Clock of Clock-gating technique doesn't occur trigger when external input conditions have not matched with a condition of logic table. We have applied our clocking technique to UART controller of 8bit microprocess

  • PDF

고속충돌 시험용 지능형 다중 카메라 시스템 개발 (Development of Intelligent Multiple Camera System for High-Speed Impact Experiment)

  • 정동택;박치영;진두한;김태연;이주연;이인석
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1093-1098
    • /
    • 2013
  • 방탄소재로서 사파이어 재료가 대두되고 있지만 고속 충돌관련 동적거동 및 파괴특성에 관한 연구는 부족한 실정이다. 탄자와 취성세라믹재료간의 상호작용을 연구하기 위해서는 고화질의 초고속 연속영상이 필수적이다. 본 연구에서는 고속충돌 및 관통 현상을 순차적으로 촬영할 수 있는 장치를 개발하였다. 이 장치는 속도측정장치, 마이크로프로세서를 사용한 카메라 구동장치 그리고 다수의 CCD카메라로 이루어져있다. 선형배열센서를 사용한 속도측정장치는 직경 1-2 mm 탄자의 마하 3 속도를 측정할 수 있다. 발사된 탄자가 속도측정장치를 통과하면 속도와 시간이 측정되고 탄자가 비행하는 동안 카메라 구동장치가 정확한 충돌시간을 계산하여 다수의 카메라에 순차적으로 트리거 신호를 보내서 충돌 전후의 형상을 순차적으로 촬영한다. 정확한 충돌시간 예측을 못하면 고해상도의 사진촬영이 거의 불가능하다. 본 연구에서 개발된 정밀 촬영장치를 사용하여 고해상도의 영상을 확보할 수 있었다.

A Study of the Compaction Effect of Expansive Admixture for the Development of an Expansive Compaction Packer

  • Kim, Jin-Chun;Park, Ki-Yeon;Lee, Dong-Ik;Lee, Gyu-Sang;Kim, Sang-Gyun;Yoo, Byung-Sun;Choi, Gi-Sung
    • 지질공학
    • /
    • 제25권2호
    • /
    • pp.179-188
    • /
    • 2015
  • Although permeating injection is ideal for grouting reservoir embankments, it is usually combined with fracturing injection for grouting, which can disturb the original soil. Compaction with low expansive pressure followed by grout injection can overcome this problem. An expansive compaction (EC) packer was developed in this work to easily apply sequential injection and compaction at a work site. Furthermore, to achieve compaction around the grouting hole, a mixture of expansive admixtures and grout was injected with the EC packer to trigger an increase in volume of the grout material. This work verifies the compaction effect of the EC packer and the expansive admixture. It reports the concepts of the EC packer, the range of expansive compaction, the effectiveness of injection, and the results of indoor tests performed to verify the effectiveness of the expansive admixtures. The indoor testing comprised a preparatory test and the main test. The preparatory test assessed the admixtures for their compaction effects, while the main test measured and analyzed the admixtures' expansive force, pressure, and compaction effect with a mold to verify the effectiveness of the compaction effect.

전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(II) (Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical (ETC) Propulsion (II))

  • 진윤식;이홍식;김종수;황동원;김진성;추증호;정재원;문희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1603-1605
    • /
    • 2001
  • Eight 300kJ modularized capacitor-banks have been constructed. These modules have been installed and assembled to make a 2.4MJ pulse power system (PPS). This 2.4MJ PPS was developed to be used as a driver of an electrothermal-chemical (ETC) gun. Each capacitor bank has six 22kV, 50kJ capacitors connected in parallel. A triggered vacuum switch (TVS-43) was adopted as a main pulse power-closing switch in each module. The module also contains a crowbar circuit made of three high-voltage diode-stacks, a multi-tap inductor and an energy-dumping resistor. Various current shapes have been formed by a sequential firing of multiple capacitor banks. Resistive dummy load has been used and various combinations of experimental parameters, such as charging voltage, trigger time and inductance, were tested to make flexible current shapes.

  • PDF

Extent of Disc Degeneration after Single-Level Cervical Anterior Microforaminotomy Analyzed with Long-Term Radiological Data

  • Han, Chul;Kim, Myung-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권3호
    • /
    • pp.200-205
    • /
    • 2014
  • Objective : To prove the extents and details of cervical degeneration after anterior microforaminotomy (AMF) with 6-years follow-up. Methods : A retrospective study of 24 patients, underwent single-level AMF, was performed. Clinical and radiologic data were analyzed with office charts, questionaires, and picture achieving and communication system images. Results : According to Odom's criteria, 91.6% achieved favorable outcome. The mean visual analog scale score was improved from 8.6 to 3, and the mean neck disability index was improved from 27.9 to 7.3 (p<0.01). Eighteen cases (75%) showed disc height (DH) decrease. The disc invasion was correlated with DH decrease (p<0.05). The disc height decrease correlated with static, dynamic changes of shell angle and spur formation (p<0.05). Any radiological parameters did not affect the clinical outcome. Conclusion : AMF is an effective technique for treating unilateral cervical radiculopathy. It showed excellent surgical outcomes even in long-term follow-ups. However, a decrease in DH occurred in a considerable number of patients. Disc invasion during surgery may be the trigger of sequential degeneration.

Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석 (Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor)

  • 김영식;윤용수;양성은;박동근;안민철;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.

Looking for Direct Evidence of Triggered Star Formation: Gas Kinematics

  • Lim, Beomdu;Sung, Hwankyung;Lee, Jae Joon;Oh, Heeyoung;Kim, Hwihyun;Hwang, Narae;Park, Byeong-Gon
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.54.1-54.1
    • /
    • 2016
  • Stellar wind and radiation pressure from massive stars can trigger the formation of new generation of stars. The sequential age distribution of stars, the morphology of cometary globules, and bright-rimmed clouds have been accepted as evidence of triggered star formation. However, these characteristics do not necessarily suggest that new generation of stars are formed by the feedback of massive stars. In order to search for any physical connection between star forming events, we have initiated a study of gas and stellar kinematics in NGC 1893, where two prominent cometary nebulae are facing toward O-type stars. The spectra of gas and stars in optical and near-infrared (NIR) wavelength are obtained with Hectochelle on the 6.5m MMT and Immersion GRating INfrared Spectrograph on the 2.7m Harlan J. Smith Telescope at McDonald observatory. In this study, the radial velocity field of gas across the cluster is investigated using $H{\alpha}$ and [N II] ${\lambda}$ 6584 emission lines, and that of the cometary nebula Sim 130 is also probed using 1-0 S(1) transition line of $H_2$. We report a distinctive velocity field of the cometary nebulae and many ro-vibrational transitions of $H_2$ even at high energy levels in the NIR spectra. These properties indicate the interaction between the cometary nebulae and O-type stars, and this fact can be a clue to triggered star formation in NGC 1893.

  • PDF