• Title/Summary/Keyword: Septic tank

Search Result 68, Processing Time 0.027 seconds

A Study on Correlation of Odorous Compounds and Odor Substance occurring in Septic Tank and Sewer Pipe (하수관거 및 정화조에서 발생하는 악취물질이 복합악취에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.165-175
    • /
    • 2013
  • This study aims to analysis correlation in septic tank and sewer pipe between odor substances and complex odor. For the analysis, convert odor substances to odor intensity, and estimate the effect of odor substances on complex odor. As a result, both Hydrogen sulfide and Methyl mercaptane of specified offensive odor substances accounted for 29 percent of the effect of odor substances on complex odor. Hydrogen sulfide and Methyl mercaptane are major cause of odor from septic tank and sewer pipe. The result of this study is suggested to be used as a preliminary data for research on analysis complex odor and odor substances.

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

A pilot-scale study on a down-flow hanging sponge reactor for septic tank sludge treatment

  • Machdar, Izarul;Muhammad, Syaifullah;Onodera, Takashi;Syutsubo, Kazuaki
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.195-204
    • /
    • 2018
  • A pilot scale study was conducted on a down-flow hanging sponge (DHS) reactor installed at a sewage treatment plant in Banda Aceh, Indonesia for treatment of desludging septic tank wastewater. Raw wastewater with an average biochemical oxygen demand (BOD) and total suspended solids of 139 mg/L and 191 mg/L, respectively, was pumped into the reactor. Two different hydraulic retention times (HRTs, 3 h and 4 h) were investigated, equivalent to organic loadings of 1.11 and $0.78kg\;BOD/m^3/d$, respectively. The average BOD concentration in the final effluent was 46 and 26 mg/L at HRTs of 3 and 4 h, respectively. The concentration of retained sludge along the reactor height was 10.2-18.7 g VSS/L-sponge, and the sludge activities were 0.24-0.32 and 0.04-0.40 mg/g VSS/h for heterotrophs and nitrification, respectively. Values of water hold-up volume, dispersion coefficient, and number of tank in-series found from tracer studies of clean sponge and biomass-loaded sponge confirmed that growth of retained sludge on the sponge module improved hydraulic performance of the reactor. Adoption of the DHS reactor by this Indonesian sewage treatment plant would enhance the role of the current desludging septic tank wastewater treatment system.

A Study on the Water Quality Management Using the Rotifers (윤충류를 활용한 하천 및 연안의 수질관리에 관한 연구)

  • Kim, Jeong-Sook
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.227-232
    • /
    • 2007
  • Water pollution in enclosed water bodies such as lake and river has become a serious problem over the world. Domestic wastewater is responsible for more than 60 % pollution load in public water area in Korea. Effluent of the treated domestic wastewater at low removal level is abundantly fed rivers and lakes and thus be an serious cause of lake pollution. Therefore, effective implement of domestic wastewater treatment in basin of lake and river must be prepared. The septic tank is one of the effective domestic wastewater treatment equipment and used in individual treatment for a unit of household, The purpose of septic tank as biological treatment system is simultaneously to remove BOD, T-N, T-P and reduce turbidity from influent. Accordingly, the appropriate control of functional microorganisms is important subject for the establishment of stability and economy of the biological treatment method. Especially, microanimals as a high-ranked microorganisms of food-chain are important, because microanimals control the other microorganisms especially various bacteria and effect on function of treatment. Therefore, it is necessary that functional predator like rotifers are attached in wastewater treatment process. In this study, the methods for attachment high density the rotifer to and improvement of transparency in the effluence by a dense rotifer was examined using laboratory scale biological treatment reactor simulated septic tank and real one.

Design of High Strength Underground FRP Septic Tank Stiffened by Circular Steel Pipe (원형강관으로 보강된 지중매립형 FRP 개인하수 처리시설의 설계)

  • Cho, Kwang Je;Kim, Sung Bo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.171-181
    • /
    • 2012
  • The design of high strength underground septic tank stiffened by steel pipe is presented and the ultimate behavior is investigated according to the full scale experiments for three types of specimens. The limitation of the current design specification are pointed out and the general design procedure of private sewage treatment facility are newly developed considering thickness of FRP shell, types of steel pipe stiffer and diaphragm wall. The direct tensile and bending test for FRP material of septic tank were performed. The increase effect of ultimate strength due to the circular steel pipe are investigated by the full scale field test and compared with the results by the finite element analysis.

Development of Amalgamated Septic Tank using Mineral Sintered Body (광물 소결체를 이용한 합병정화조 개발에 관한 연구)

  • 김광수;김영훈;강헌찬
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.56-62
    • /
    • 2000
  • This study was introduced an amalgamated septic tank system using mineral sintered body was made from non-metallic minerals with a ability being attached or accelerating a vitality of soil microorganism for the effective wastewater treatment. Experimentally, we made an amalgamated septic tank appling anaerobic-aerobic process experimental facilities to two personal houses for handling a residental sewage directly on a small scale from the place of origin. The results are shown as follows; The COD\ulcorner and BOD of effluent were about 10 mg/l after the treatments and T-N removal efficiency was 60-70%. Moreover these results suggested the possibility of denitrification without adding organics and more than 80% of T-P removal also showed the possibility of wastewater treatment biologically.

  • PDF

The Effect of Hydraulic Loading on the Performance of Biofilter System (수리부하량 변화에 따른 바이로필터의 처리효율에 관한 연구)

  • 방천희;김철성;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.789-794
    • /
    • 1999
  • The performance of a small on-site wastewater treatment system consisting of an anaerobic septic tank and upgraded absorbent biofilter was investgted . The anaerobic septic tank was used as a pre-treatment of the absorbent Biofitler instead of the primary clarifier. The treatment capacity of the system was examined by changing the hydraulinc loadings to the Absorbent Biofilter as 2.5㎥/day , 4.5㎥/day, 6.0㎥/day, respective. The effluent from the septic tank was fed into the Absorbent Bilfilter. Based on the experimental results, the quality of treated wastewater satisfied the regulation and the BOD and SS was removed down to approximately 5mg/$\ell$ and 1mg/$\ell$, respectively.

  • PDF

Prediction of Sludge's Volume Collected from Septic Tank Cleaning in Seoul (분뇨수거량 평가방법 연구 : 서울시를 중심으로)

  • Yoo, Kee Young;Cho, In Sung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.4
    • /
    • pp.138-146
    • /
    • 2007
  • There are still lots of areas where are covered with combined sewer pipes in Seoul. All buildings within those areas are equipping septic tanks which take part in separating solids from flushing water of chamber pots. Septic tanks legally demand emptying and cleaning the those inner bodies, resulting the generation of sludge which should be purified using the specified treatment plants, as one of environmental infrastructures. Scale of treatment plants for septic tank sludge are affected by sludge volume generated from cleaning, which give emphasis to adequate estimation of sludge volume in the future. This study aimed to define prediction tools for sludge volume. Among various parameters, floor area of building is most reasonable one to estimate the quantity of cleaning sludge, showing increasing gradually up to 13,149kL a day in 2020. Using same parameter also are able to assess the amount of BOD in the cleaning sludge.

  • PDF

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

Attached Treatment using Combined Septic Tank and Soil Filter of Treated Livestock and Farm House Wastewater (축산폐수 처리수 및 농가 생활잡배수의 합병정화조와 Soil Filter 에 의한 연계처리)

  • Kim, Eun-Ho;Park, Hyun-Geoun;Sung, Nak-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.4
    • /
    • pp.329-334
    • /
    • 1998
  • This study was conducted in order to investigate removal rate of organic matter, nitrogen and phosphorus to reduce environmental polluation with treatment to attach combined septic tank to 3 stage soil filter after mixing anaerobic treated water of livestock wastewater and low concentrated wastewater generated in farm house. Because anaerobic filter bed was packed in combined septic tank and a microorganism was accumulated in combined septic tank with increasing hydraulic retention time(HRT), if HRT $4{\sim}12day$, CODcr was removed $63.4{\sim}84.0%$. Also, $NH_4\;^+-N$ and $PO_4\;^{3-}-P$ were removed $3.9{\sim}5.4%$ and $18.3{\sim}29.0%$, respectively. In being re-treated by 3 stage soil filter, although hydraulic loading rate was gradually increased, CODcr, $NH_4\;^+-N$ and $PO_4\;^{3-}-P$ were removed above 90% due to filtration, adsorption, ion exchange, and action of soil microorganism. Generally, the attached treatment of combined septic tank and 3 stage soil filter did suitably treat livestock wastewater to water standard of discharge applied from '96 year, in view of decreasing pollution loading amount and recycling of agricultural water.

  • PDF