• 제목/요약/키워드: Septic tank

검색결과 68건 처리시간 0.027초

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토 (Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

인공습지의 농촌지역 오수정화시설에 적용가능성 연구 (Feasibility Study of Constructed Wetland for the Wastewater Treatment in Rural Area)

  • 윤춘경;권순국;권태영
    • 한국농공학회지
    • /
    • 제40권3호
    • /
    • pp.83-92
    • /
    • 1998
  • Field experiment was performed from August 1996 to January 1998 to examine the applicability of constructed wetland system for wastewater treatment in rural area. The pilot plant was installed in Kon-Kuk University and the school building septic tank effluent was used as an influent to the treatment basin. Hydraulic loading rate was about 0.1 6$0.16^3/m^2$ day and theoretical detention time in the system was 1.38 days. The treatment basin was composed of sand and reed. The influent DO concentration was low and many cases close to zero, but effluent concentration was higher than the influent which implies that oxygen was supplied naturally. The average concentration of influent BOD was 126mg/L, and with average removal rate of 69 % the average effluent concentration was 4Omg/L which satisfied the effluent water quality standard for the system of interest. The average influent concentration of COD was 2Olmg/L and average effluent concentration was 75mg/L with average removal rate of 60%. The performance of BOD and COD tends to deteriorate in the low temperature, and appropriate action needs to be taken during the cold winter time for stable operation. The average influent concentration of SS was 5Omg/L, and effluent was 1 1mg/L with average removal rate of 76% which satisfied the effluent water quality standard for the system of interest. The results for the regulated components, SOD and SS, from the experiment showed that constructed wetland system can meet the effluent water quality standards. The average influent concentration of total phosphorus was 25.6mg/L and average effluent concentration was 7.8mg/L with average removal rate of 63%. Not like the performance of the above components, average nitrogen removal rate was only 11.2% which is not satisfactory. Although, nitrogen is not regulated at this moment, it can cause many environmental problems including eutrophication. Therefore, nitrogen removal efficiency should be improved for actual application. From the result of the field experiment, constructed wetland system was thought to be an appropriate alternative for wastewater treatment in rural area.

  • PDF

인공습지 오수처리시설의 처리성능에 관한 연구 (Study on the Performance of Constructed Wetland System for Sewage Treatment)

  • 윤춘경
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.96-105
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the performance of constructed wetland system for wastewater treatment in rural area. The constructed wetland system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand bed with planted reed. From August 1996 to June 1998 the hydraulic loading rate was fixed with about 15.63cm/day and theoretical detention time was 1.38 days, and from July 1998 to December 1999 the hydraulic loading rate was about 6.25cm/day and theoretical detention time was 3.5days. It worked continuously even during winter time, and the sewage flowed without freezing even when average daily air temperature was below -1$0^{\circ}C$. Average removal rate of BOD , COD, and SS was about 70%, T-P removal rate was about 50.8% , and T-N removal rate was 23.9%. The reason for poor T-N removal might be due to high influent concentration and short retention times. At the later years BOD and COD removal rates were increased , and SS and T-P removal rates did not change significantly , but T-N removal rates were decreased. The effluent of the wetland system often effluent water quality standards for sewage treatment plant, therefore, further treatment would be required if the effluent need to be discharged to the public water. Wetland system involves relatively large land area and could be suitable for rural area. Therefore, utilization of reclaimed sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage in rural area.

  • PDF

복잡한 지형에서 발생하는 지하수의 질산태 질소 오염원 평가 (Contamination Source Assessment of Groundwater Nitrate in a Complex Terrain)

  • 한광현
    • 한국토양비료학회지
    • /
    • 제42권1호
    • /
    • pp.14-20
    • /
    • 2009
  • 토지이용에서 보았을 때 제주도는 해안을 따라 넓게 분포하는 밭과 과수원의 화학비료와, 중산간 지대 방목지의 가축분뇨 및 산발적으로 존재하는 주거지역의 생활하수에 의한 질산태 질소 오염이 추정되었다. 질소동위원소 분석이 이들 오염원들을 구분하기 위하여 사용되었으며, 주요 오염원인 요소, 유안, 축분정화조, 축분유기질 비료에 대해 측정된 $\delta^{15}N$ 값을 토대로 화학비료에 의한 오염은 5‰ 이하, 생활하수 혹은 가축분뇨에 의한 오염은 10‰ 이상으로 기준을 정하였다. 제주도 전역에 걸친 33개 관정의 질산태 질소 동위원소 분석결과는 대부분의 관정이 화학비료에 의해 오염되었으며, 일부 관정이 가축분뇨와 생활하수에 의해 영향받았음을 나타내었다. 이러한 결과는 질소동위원소분석이 토지이용분류로는 판별하기 어려운 오염원 추정에 매우 유용한 수단이 될 수 있음을 나타낸다. 특히 좁은 지역에서 토지이용이 다양하게 이루어 지고 있는 경우에 중요한 오염원 추정 수단이 될 수 있음을 경기, 강원 지역의 지하수 분석을 통해 확인할 수 있었으며, 또한 두 가지 이상의 오염원이 동시에 작용할 수 있고 그 기여도가 시기별로 달라질 수 있음을 확인하였다.

질소 동위 원소 분석을 이용한 경기도 지역 지하수 중 질산태 질소 오염원 구명 (An Investigation of the Sources of Nitrate Contamination in the Kyonggi Province Groundwater by Isotope Ratios Analysis of Nitrogen)

  • 류순호;최우정;한광현
    • 한국토양비료학회지
    • /
    • 제32권1호
    • /
    • pp.47-56
    • /
    • 1999
  • 경기도 군포시 및 수원시에서 축산지역과 영농지역 및 주거지역의 토지이용방식을 반영하는 14곳의 지하수 과측정을 대상으로 1997년 1원부터 12월까지 지하수 시료를 채취하여 지하수질의 화학성과 질산태 질소농도를 소사한 결과 지하수의 양이온 조성은 토지이용방식에 따라 큰 차이가 없었지만, 음이온 조성에서는 축산지역 소재 지하수의 $NO{_3}^-$의 비율이 상대적으로 높았다. 영농지역 지하수의 질산태질소 농도는 영농활동의 영향으로 4월과 7월사이에서 증가하는 것으로 나타났으며, 축산지역 지하수는 강우유형에 영향을 받는 것으로 판단할 수 있었고 주거지역의 질산태질소농도는 시기에 상관없이 일정한 수준을 유지했다. 질산태 질소의 오염원을 구명하기 위해 Urea, Ammonium sulfate, 축산 폐수, 청정지역 지하수 중에 포함된 질소의 동위원소비를 측정한 결과 각각 +1.4, -2.7, +27.2, +5.5% 로 나타나 이 ${\delta}^{15}N$ 값을 근거로 지하수중 질산태질소의 ${\delta}^{15}N$ 값이 +5% 이하인 경우 화학비료영향 +5~+10‰은 토양 질소, +10‰ 이상은 축산폐수 또는 생활하수 영향으로 오염원 구분기준을 설정할 수 있었다. 관측정 지하수중 질산태 질소의 ${\delta}^{15}N$ 값은 대부분 토지이용방식에 따른 오염원을 반영했지만, 영농과 축산이 복합적으로 운영되는 농촌지역의 특성상 단일 오염원보다는 두 종류 이상의 오염원이 공동으로 지하수질에 영향을 미치는 것으로 판단할 수 있었다. 또한 각 오염원의 오염 기여도는 관측정 주위의 토지이용방식에 따라 차이가 있었지만, 같은 관측정 내에서도 시기에 따라 그 기여도가 변함을 알 수 있었다.

  • PDF

대전지역 민방위 비상급수용 지하수에 대한 수리화학과 질소 및 황 동위원소 연구 (Hydrochemistry and Nitrogen and Sulfur Isotopes of Emergency-use Groundwater in Daeieon City)

  • 정찬호
    • 지질공학
    • /
    • 제13권2호
    • /
    • pp.239-256
    • /
    • 2003
  • 이 연구에서는 대전지역 민방위 비상급수용 지하수의 수리화학적 특성을 밝히고 질소 및 황 동위원소를 분석하여 질산성 질소와 황산염의 기원을 해석하고자 하였다. 지하수의 수질화학적 특성은 전반적으로 약산성화 되어 있으며, 전기전도도 값은 $142~903{\;}\mu\textrm{S}/cm$의 범위로 평균 $352{\;}\mu\textrm{S}/cm$을 보인다. 지하수의 화학적 유형은 $Ca-HCO_3$ 형에서 Ca-Cl ($SO_4,NO_3$) 형까지 넓게 분포한다. 지하수의 $CO_2$ 함량과 pH에 의해 결정되는 $EpCO_2$ 값을 유기오염의 지수로 활용하였다. 지역별 지하수의 성분을 비교하고 성분별 농도분포를 알아보기 위하여 박스-휘스커(Box-Whisker) 다이아그램과 등치선도를 작성하였다. 수리화학적 자료를 종합하면 동구와 중구, 대덕구 일대 구도심권의 지하수가 약산성의 높은 전기전도도 특성과 높은 $NO_3$, $SO_4$, $EpCO_2$ 분포를 보여 서구와 유성구에 비해 오염이 많이 진행된 상태를 보인다. 지하수 22개 시료에 대한 ${\delta}^{15}N$ 분석 값은 서구와 유성구의 지하수에서 ${\delta}^{15}N$ 값이 $+7.4~+9.6{\textperthousand}$ 범위를 보여 지하수내 질산성질소 오염은 생활하수의 가능성이 높다. 그리고 동구, 중구, 대덕구 등 구도심권 지하수의 ${\delta}^{15}N$ 값은 $+10.2~+23.5{\textperthousand}$의 범위를 보여 정화조에서의 누출수가 주요 오염원일 가능성이 있다. 그리고 지하수의 ${\delta}^{34}S$ 값은 $+3~13.4{\textperthousand}$의 범위를 보인다. 일부 지하수 시료는 황산염 환원반응을 거쳐 $10{\textperthousand}$이상의 높은 ${\delta}^{34}S$ 값을 보이고, $7{\textperthousand}$ 내외의 ${\delta}^{34}S$ 값을 보이는 지하수는 황철석과 대기기원 외에도 인위적 오염에 의한 황 성분의 유입 가능성을 배제할 수 없다.

핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰 (A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department)

  • 유재숙;장정찬;이동훈;차민경;남기표
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.70-74
    • /
    • 2011
  • 서울 아산병원 핵의학과에서는 방사성폐기함을 다수 비치하여 방사성폐기물을 수집하고 있으나 이러한 방사성폐기물이 일반 의료폐기함에서 발견되는 경우가 있다. 이에 본 연구에서는 의료폐기물에서 측정되는 방사성폐기물의 발생 원인을 파악하여 방사선관리구역으로부터 배출되는 물품 표면의 방사성물질의 오염도가 허용표면오염도의 10분의 1을 초과하지 않거나 교육과학기술부에서 고시하는 액체폐기물이 방사성 자체 폐기한도를 초과하지 않도록 하기 위한 대책을 제시하고자 하였다. 우선 먼저 survey meter를 이용하여 본원 핵의학과 17개 구역의 방사능 측정값과 배후방사능 측정값을 비교한 결과 법적인 허용치를 초과하지는 않았지만, 이 중 11개 구역에서 의료 폐기함과 배후방사능이 통계적으로 유의한 차이를 보여 실제 방사능이 존재함을 알 수 있었다. 이에 좀 더 정확한 방사능을 측정하고자 감마카운터를 이용하여 각각의 의료폐기함으로부터 알코올솜, poly glove, 방사의약실에서 배출되는 생리식염수에서 각각 30개씩 표본 추출하여 측정한 결과, 높은 수준의 방사능이 측정되었으며, 일부는 법적 허용치를 초과했다. 따라서 의료폐기함으로 폐기되는 알코올솜과 poly glove는 각 영상실과 방사의약실에 구비된 방사성폐기함에 폐기하고, 방사의약실에서 발생되는 생리식염수는 액체폐기물로써 RI정화조에 폐기하거나 또는 방사성 자체 폐기절차에 따라 일정기간 보관하여 충분히 감쇄시킨 후 폐기해야 할 것이라 사료된다.

  • PDF