• 제목/요약/키워드: Septage

검색결과 4건 처리시간 0.02초

하수(下水) 처리장(處理場)에서 정수조폐액(淨水槽廢液)의 혐기성소화(嫌氣性消化) 처리(處理)에 관한 연구(硏究) (Anaerobic Digestion of Thickened Septage at Municipal Wastewater Treatment Plant)

  • 최의소;김태형;이호식
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.13-19
    • /
    • 1993
  • Anaerobic Digestion of thickened septage was investigated in this study. Thickening could reduce the volume of septage to be treated to about 40% with 12hr HRT. The VS and BOD removal efficiencies were respectively 28 to 45%, and 75% when digested the thickened septage with 30 day HRT Or $1.4kgVS/m^3/d$. The BOD removal efficiency could be increased to about 90% with subsequent settling tank with about 6 hours HRT. The gas production rate was 0.22 to $0.35m^3gas/kgVSadd$($0.75m^3gas/kgVSrm$), or $1.32m^3gas/kgBOD_{rm}$. In addition, the supernatant of thickener could be returned to the aeration tank treating domestic sewage. In this case, a BOD loading rate of 0.5 to $0.7kgBOD/m^3/d$ or 0.5kgBOD/kgMLVSS/d was proposed for 80% BOD reduction.

  • PDF

A pilot-scale study on a down-flow hanging sponge reactor for septic tank sludge treatment

  • Machdar, Izarul;Muhammad, Syaifullah;Onodera, Takashi;Syutsubo, Kazuaki
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.195-204
    • /
    • 2018
  • A pilot scale study was conducted on a down-flow hanging sponge (DHS) reactor installed at a sewage treatment plant in Banda Aceh, Indonesia for treatment of desludging septic tank wastewater. Raw wastewater with an average biochemical oxygen demand (BOD) and total suspended solids of 139 mg/L and 191 mg/L, respectively, was pumped into the reactor. Two different hydraulic retention times (HRTs, 3 h and 4 h) were investigated, equivalent to organic loadings of 1.11 and $0.78kg\;BOD/m^3/d$, respectively. The average BOD concentration in the final effluent was 46 and 26 mg/L at HRTs of 3 and 4 h, respectively. The concentration of retained sludge along the reactor height was 10.2-18.7 g VSS/L-sponge, and the sludge activities were 0.24-0.32 and 0.04-0.40 mg/g VSS/h for heterotrophs and nitrification, respectively. Values of water hold-up volume, dispersion coefficient, and number of tank in-series found from tracer studies of clean sponge and biomass-loaded sponge confirmed that growth of retained sludge on the sponge module improved hydraulic performance of the reactor. Adoption of the DHS reactor by this Indonesian sewage treatment plant would enhance the role of the current desludging septic tank wastewater treatment system.

혐기성(嫌氣性) 소화방식(消化方式)에 의한 분뇨(糞尿)와 정화조(淨化槽)슬러지의 혼합처리(混合處理) 실험(實驗)에 관한 연구(硏究) (Treatability Study for the Nightsoil and Septic Tank Sludge by Anaerobic Digestion)

  • 이광호;신응배;한건연
    • 대한토목학회논문집
    • /
    • 제2권1호
    • /
    • pp.69-80
    • /
    • 1982
  • 본(本) 연구(硏究)는 분뇨처리(糞尿處理)의 효율화( 效率化) 방안(方案)으로 정화조(淨化槽)슬러지와 생분뇨(生糞尿)를 현존(現存) 소화식(消化式) 분뇨처리장(糞尿處理場)에서 혼합처리(混合處理)할 수 있는 방안(方案)을 검토(檢討)할 목적(目的)으로 분뇨(糞尿) : 정화조(淨化槽)슬러지의 혼합비율(混合比率)을 9 : 1(#1), 7 : 3(#2)으로 하여 처리도(處理度) 실험(實驗)을 수행(遂行)하였다. 실험결과(實驗結果) 유기물(有機物)의 제법효율(除法效率)은 9 : 1(#1)의 비율(比率)에서 BOD 80%, COD 80%, TS 63%, VS 76%이었으며 7 : 3(#2)의 비율(比率)에서는 BOD 87%, COD 82%, TS 66%, VS 78%로 정화조슬러지를 분뇨처리장에서 혼합처리(混合處理)할 수 있는 충분(充分)한 가능성(可能性)을 보여주었다.

  • PDF

분뇨처리(糞尿處理) : 혐기성소화(嫌氣性消化) 온도영향(溫度影響) (Nightsoil Treatment: Temperature Effects on Anaerobic Digestion)

  • 최의서;이병헌;이찬기
    • 대한토목학회논문집
    • /
    • 제2권3호
    • /
    • pp.23-32
    • /
    • 1982
  • 본연구(本硏究)는 다절기(多節期)에는 저온(低溫)으로 하절기(夏節期)에는 고온(高溫)으로 혐기성(嫌氣性) 소화조(消化槽)를 운전(運轉)시킬 수 있는지를 검토(檢討)하기 위한 것으로 실험실(實驗室) 완전혼합형(完全混合型) 혐기성(嫌氣性) 소화조(消化槽)를 $18.5^{\circ}C$ 부터 $60^{\circ}C$까지의 11단계(段階)의 온도(溫度)에서 유기물질(有機物質)의 제거효율(除去効率) 가스생산량(生産量)을 서로 비교(比較)하였다. $35^{\circ}{\sim}40^{\circ}C$ 내외(內外)에서 BOD와 VS 제거효율(除去効率)은 각각(各各) 71%와 53%였으며 이 온도(溫度)에 있어서 가스생산량(生産量)은 주입분뇨량(注入糞尿量)의 16배(倍) 또는 $0.63m^3gas/kg$ VS fed 였다. 화조(消化槽) 유출수(流出水)를 심전(沈殿)시키면 BOD제거효율(除去効率)은 78%까지 상계(上界)하였다. 본실험(本實驗)의 결과(結果)는 $32^{\circ}$에서 $47^{\circ}C$로 운전(運轉)시킨 기존(旣存) 분뇨처리장(糞尿處理場)의 결과(結果)와 $40^{\circ}C$까지는 비교적(比較的) 잘 맞았으나 $40^{\circ}C$ 이상(以上)에서는 실험실(實驗室) 결과(結果)가 처리효율(處理効率)이나 가스생산량(生産量)으로 볼 때 양호(良好)하였다. 분뇨(糞尿)에 정화조폐액(淨化槽廢液)이나 우분(牛糞) 혼합처리(混合處理) 가능성(可能性) 검토(檢討)하였는데 1:1로 혼합처리(混合處理)시켰을 때의 BOD제거효율(除去効率)이나 가스생산량(生産量)이 분뇨(糞尿)만의 처리시(處理時)와 별로 차이(差異)가 없었다. 한편 혐기성(嫌氣性) 소화조(消化槽)의 유출수(流出水)를 희석(稀釋)없이 호기성처리(好氣性處理)도 가능(可能)한지 알아 보았는데 이때의 BOD와 SS제거효율(除去効率)은 98% 이상(以上)이었다.

  • PDF