• Title/Summary/Keyword: Separators

Search Result 150, Processing Time 0.027 seconds

A Review on Swirling Flow by Using Flow Visualization Techniques in the Circular Tubes (원형관 내에서 유동가시화 기법을 이용한 선회유동에 관한 연구고찰)

  • Chang, Tae-Hyun;Doh, Deog-Hee;Lee, Kwoon-Soo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.12-21
    • /
    • 2010
  • Swirling flows are found in very wide range of applications, for examples, cyclone separators, spraying machines, heat exchangers and jet pumps, ect. Relatively, little work has been done on the swirl flow using flow visualization techniques. This study deals with many visualization techniques to study on swirling flow. These techniques are related to oil films methods, smoke, dye liquids, liquid crystal, stroboscope light, smoke wire, white light, naphthalene sublimation, LDV(lase doppler Velocimetry) and PIV(particle image velocimetry). The present work has handled single, annular, carved tube, swirl expansion and swirl wake using several visualization methods in the vertical and horizontal circular tube.

Effect of various fillers on the moldability and electrical conductivity of PEMFC Separators made of thermoplastic composite (열가소성 복합재의 충전된 첨가제에 따라 사출성형 한 PEMFC Separator의 전기전도도 특성 연구)

  • Yoon, Yong-Hun;Lim, Seung-Hyun;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.671-674
    • /
    • 2009
  • 본 논문에서는 Base resin으로 열가소성 고분자인 PPS(Poly(phenylene sulfide))를 사용하였으며, 물리적 및 화학적 특성을 증대시키기 위해 주 첨가제로는 Expanded graphite와 보조 첨가제로 Glass fiber와 Carbon fiber를 사용하여 2가지의 복합 소재를 제조 하였다. 제조한 복합소재를 활용하여 최적의 사출 조건(사출 압력, 가열시간, 금형온도 등)으로 사출을 하였으며, 각각의 최종 시편을 four point probe 장치를 사용하여 전기전도도를 측정 비교 하였다.

  • PDF

Fabrication of Macroporous Silicon Diaphragms (매크로기공을 갖는 다공질 실리콘 다이어프램의 제작)

  • Min, Nam-Ki;Ha, Dong-Sik;Jeong, Woo-Sik;Min, Suk-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1558-1560
    • /
    • 1998
  • Macroporous silicon diaphragms 20 to $200{\mu}m$ thick have been formed on p-type silicon by anistropic etching in TMAH solution and then by electrochemical etching in HF-ethanol-water solution with an applied current. The pores have a pore diameter of $1.5{\sim}2{\mu}m$, with a depth of $20{\sim}30{\mu}m$ and are not interconnected, which are in sharp contrast to the porous silicon reported previouly for similarly doped p-Si. The fabrication of macroporous silicon and free-standing diaphragms is expected to offer new applications for microsensors, micro-machining, and separators.

  • PDF

Emulsified Oily Wastewater Treatment by MHD Water Treatment Device (MHD 수처리방식에 의한 에멀젼오일폐수의 처리)

  • 김인수;박승조
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.20-27
    • /
    • 1993
  • Emulsified oily wastewater is generally hard to treat in separating oil and water by conventional separators. In this paper the magnetohydrodynamic water treatment device was used to separate oil from emulsified oily wastewater which contained high conductivity. The emulsified oil removal rates and economic ranges of oil separation at various factors were investigated to confirm the influence of the magnetic field in MHD water treatment device according to the characteristics of emulsion brake. Experimental results proved that the oil removal rates were proportional to Lorentz force which depends on the intensity of magnetic field, conductivity and velocity of wastewater.

  • PDF

Study on optimum structure of free-breathing Polymer Electrolyte Membrane Fuel Cell (PEMFC) for robotic application (로봇용 자연급기형 연료전지의 최적구조에 관한 연구)

  • Choi, Jae-Hyuk;Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.231-238
    • /
    • 2006
  • The performance of free-breathing polymer electrolyte membrane fuel cell (PEMFC) was studied experimentally and the effect of cathode separator structure on the cell performance was investigated. Cathode separators were used for the cell with $18cm^2$ active area. In channel type, the contact resistance is low, and the nature convection. which is strongly affected by the cross-sectional shape of cathode separator channel, is dominant in a cell performance. The maximum power density with $18cm^2$ active area is $105mW/cm^2$ using the 10mm depth and 2mm width channel. A computational analysis was optimum structure of free-breathing channel type PEMFC for robotic application.

Separation of PET and PS with Air Separation

  • Nakazawa, Hiroshi;Kudo, Yasuo;Sato, Hayato
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.727-729
    • /
    • 2001
  • The air separation of PET (Polyethylene terephthalate) and PS(Polystyrene) was carried out by taking advantage of the different abrasive resistance of two plastics. PET bottles and PS packages were shredded to small square pieces $(5{\times}5mm)$. Both plastic shreds were treated by a shear-type crusher. The PET shreds were bent and twisted by the crush so that they were blown up easily, but the PS shreds were not. After the crush of mixture of both plastics, air separation experiments were carried out using four types of air separators. The number and location of the baffle attached to them are different. With the separator with a baffle attached at the upper part, PET recoveries for the crushing time of 30, 60 and 90sec were 67, 98 and 99% respectably at the air flow rate of 3.5m/s, whereas PS recoveries were null regardless of the crushing time.

  • PDF

DNA Separation Chips Using Asymmetrically-Switched Nonuniform Electric Fields (비대칭 교차전기장의 불균일 분포를 이용한 DNA 분리 소자)

  • Yi, So-Yeon;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.265-268
    • /
    • 2009
  • We present the experimental study to realize a DNA separation chip using asymmetrically-switched nonuniform electric fields. The DNA separation chip redistributes DNA molecules within a specific area based on the size- and field-dependent nonlinearity of DNA drift velocity. The present chip is composed of a width variable channel to distribute nonuniform electric field, a DNA loading slit and a pair of electrodes to apply electric field. We focus on the design of DNA separation chips with identifying the nonlinearity of DNA drift velocity using three different DNA molecules (11.1kbp, 15.6kbp, and 48.5kbp) in the chips. It is demonstrated that different size of DNA shows different net migration in different direction under the asymmetrically-switched nonuniform electric field.

Weld Quality of MCFC Separators With Large Active Area (MCFC용 대면적 분리판의 용접부 품질에 관한 고찰)

  • Kim, K.C.;Jun, J.H.;Kim, S.G.;Kuk, S.T.;Lim, H.C.;Jung, B.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.135-138
    • /
    • 2009
  • Quality evaluation of laser welded MCFC separator panels with large active area was performed. Lap joint was applied to produce stable air-tight seam weld by employing Nd:YAG laser. Results showed that surface contamination played a key role to form weld defects at the joint interface. However, there was no evidence that weld width at the lap joint changed after the stack operation time of 2,890h. Test results also revealed that the reinforcement values which were measured on the weld line after long time operation, were stable.

  • PDF

Heat and Flow Analysis of a Parallel Flow Heat Exchanger Using Porous Modeling (다공성 모델링을 이용한 평행류 열교환기의 열.유동 해석)

  • Jeong, Gil-Wan;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1784-1792
    • /
    • 2001
  • Numerical analysis on a parallel flow heat exchanger(PFHE) is performed using 2 dimensional turbulent porous modeling. This modeling can consider three-dimensional configuration of passage (flat tube with micro-channels), and the stability and accuracy of numerical results are improved. The geometrical parameters(e.g., the position of separators, inlet/outlet, and porosity of passages of a PFHE) are varied in order to examine the flow and thermal characteristics and flow distribution of the single phase multiple passages system. The flow non-uniformities along the paths of the PFHE are observed to evaluate the thermal performance of the heat exchanger. The location of inlet affects the heat transfer, and the location of outlet affects the pressure drop. The porosity with the optimum thermal performance is around 0.53.

K-Ar Muscovite Dating for Precambrian Granites in the Sangdong Area (상동지역(上東地域) 선캠브리아 화강암류(花崗巖類)의 K-Ar 백운모(白雲母) 연령측정(年齡測定))

  • Yun, Hyun Soo
    • Economic and Environmental Geology
    • /
    • v.24 no.1
    • /
    • pp.21-25
    • /
    • 1991
  • The studied Nonggeori and Naedeogri granites in the Sangdong area intruded into the Precambrian metasedimentary rocks of the Yulri Group. The Cambro-Ordovician Choseon Supergroup overlied unconformably upon the Yulri Group. Pegmatitic dykes injected into the Yulri Group and the granites, but not in the Choseon Supergroup. Field relationships suggest approximate ages of the intrusive rocks in the studied area belong to the Precambrian. Extremely pure concentrates of muscovites(40-80#) were obtained from the granites by conventional isodynamic magnetic separators. The contents of K and 40Ar in the muscovites show 8.60-8.78% and 98.52-99.11%, respectively. From the potassium contents of the muscovites and the approximate ages, the sample amounts for argon analyses are average of 0.00371gr. The K-Ar ages on the muscovites were revealed as Proterozoic ($1673{\pm}22{\sim}1802.5{\pm}17.5Ma$).

  • PDF