• Title/Summary/Keyword: Separate inspection box

Search Result 2, Processing Time 0.021 seconds

Development of an Inspection Box for a Guard Lamp with an Automatic Switch (자동점멸식 보안등 점검함 개발)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.34-40
    • /
    • 2008
  • In this paper, a device for safety inspection of a guard lamp with an automatic switch which has been recently employed in some local autonomous entities was developed. It is technically enhanced by installing a separate inspection box down below, which allows the inspectors can measure the leakage current, the sound function of the electric leakage breaker(ELB), the insulation resistance and the grounding resistance, on the ground. This inspection box makes the inspectors free from the electric shock by being designed to minimize the potential direct contact with the energized terminals. The deliverables of this paper are expected to contribute to carry out the inspection for the guard lamps safely and effectively.

A Study on Shrinkage Crack of Steel Composite Concrete Box Structure (Transfer Girder) (강합성 콘크리트 박스구조물(트랜스퍼 거더)의 건조수축 균열에 대한 연구)

  • Choi, Jung-Youl;Kim, Dae-Ill
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.685-691
    • /
    • 2022
  • This study was based on the steel composite concrete box structure (Transfer girder) which was installed to support the skyscrapers directly above the subway line. In this study, it was analytically proved that the cause of cracks on the steel composite concrete box structure were the shrinkage cracks by comparing the results of crack investigation and numerical analysis. As the results, it was found that the internal temperature difference between concrete and steel members occurred according to the shape of the steel frame embedded in concrete, the location of vertical stiffener, and the closed section area. The narrower spacing of vertical stiffener was occurred the internal temperature concentration of the structure and the temperature difference increased. And the location of higher thermal strain and temperature were similar to the location of actual cracks by the visual inspection. Therefore, the internal temperature concentration parts were formed according to the presence and spacing of the vertical stiffeners and the inspection passage in the central part of the structure. The shrinkage cracks were occurred by the restrained of temperature expansion and contraction of the concrete. As the results of this study, it was important to separate and manage the non-structural cracks caused by shrinkage and the structural cracks in the maintenance of serviced steel-composite concrete structures.