• 제목/요약/키워드: Sensor electrode

검색결과 754건 처리시간 0.026초

Electrical stabilities of half-Corbino thin-film transistors with different gate geometries

  • Jung, Hyun-Seung;Choi, Keun-Yeong;Lee, Ho-Jin
    • Journal of Information Display
    • /
    • 제13권1호
    • /
    • pp.51-54
    • /
    • 2012
  • In this study, the bias-temperature stress and current-temperature stress induced by the electrical stabilities of half-Corbino hydrogenated-amorphous-silicon (a-Si:H) thin-film transistors (TFTs) with different gate electrode geometries fabricated on the same substrate were examined. The influence of the gate pattern on the threshold voltage shift of the half-Corbino a-Si:H TFTs is discussed in this paper. The results indicate that the half-Corbino a-Si:H TFT with a patterned gate electrode has enhanced power efficiency and improved aperture ratio when compared with the half-Corbino a-Si:H TFT with an unpatterned gate electrode and the same source/drain electrode geometry.

불화물을 이용한 산소센서의 제조및 특성 (Fabrication and Characteristics of Oxygen Gas Sensor using Fluoride Compaunds)

  • 이재현;홍영호;장동근;이병택;김태훈;이덕동
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 1993년도 추계 학술발표 강연 및 논문 개요집
    • /
    • pp.69-71
    • /
    • 1993
  • Fluoride compound potentiometric cell oxygen sensors were fabricated for the measurement of oxygen pressure in the low temperature range (300。K-500。K). The disk type sensors consist of a reference Air(0$_2$):Ag, a solid electrolyte SrF$_2$, and a sensing metel Ag electrode. And the buried reference electrode type sensor have a NiO/Ni reference electrode. The open circuit emf of the cell showed high sensivity to oxygen gas (60mv) at the measuring temperature 20$0^{\circ}C$. Also, The buried reference electrode type sensor showed 30mv from 1% to 10% oxygen pressure range.

  • PDF

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

근전의수용 소형 표면 근전위 센서의 개발 (Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis)

  • 최기원;성소영;문인혁
    • 전자공학회논문지SC
    • /
    • 제42권6호
    • /
    • pp.67-76
    • /
    • 2005
  • 본 논문에서는 근전의수용 소형 근전위 센서를 제안한다. 근전의수용 근전위 센서를 의수 소켓에 내장시키기 위해서는 소형이어야 한다. 제안된 근전위 센서는 피부와 접촉하는 전극과 신호처리를 위한 회로부가 일체화된 형태로 소형화 하였다. 기준 전극은 두 입력전극의 가운데에 나란히 배치되고, 입력전극은 막대형, 기준전극은 막대형과 원형의 두 가지 형상으로 설계하였다. 두 입력전극 사이의 간격은 근섬유의 근전위 신호의 전도속도와 중심주파수를 고려하여 18mm, 20mm, 22mm 의 세 개의 서로 다른 간격을 가진 전극을 제작하였다. 사용된 전극의 재료는 땀이나 습기에 강한 SUS440 금속을 사용하였다. 신호처리 회로부는 대역통과 필터를 갖는 차동 증폭기, 전원노이즈를 제거하기 위한 대역저지 필터, 교류결합증폭기, 절대평균값 회로로 구성되어 있다. 실험에서는 정상인의 전완에서 근전위 신호를 취득하여 주파수 분석하고, 입력전극 사이의 간격과 기준전극의 형상에 따른 출력특성 평가하였다. 본 논문에서는 실험의 결과로부터 두 입력전극간의 거리가 18mm 이면서, 입력전극의 형상과 기준전극의 형상이 모두 막대형인 표면 근전위 센서가 근전의수에 최적임을 보인다.

완충용액유속, 효소.기질 반응 및 전극봉 요인에 따른 발효공정 제어용 흐름주입식 효소센서의 전류값 특성 (Current Characteristics of a Flow Injection Type Enzyme-Sensor as the Variables of a Buffer Velocity, an Enzyme-Substrate Reaction and an Electrode for the Control of a Fermentation Process)

  • 송대빈;정효석;김성태
    • Journal of Biosystems Engineering
    • /
    • 제32권6호
    • /
    • pp.455-461
    • /
    • 2007
  • The electric current of a flow injection type enzyme-sensor was measured to confirm the stable operating conditions of the sensor. The current of the sensor was decreased as the buffer solution velocity increased. Under the limitation of the cycle time to be below 10 minutes, the effective ranges of the buffer solution velocity were suggested $0.10{\sim}0.26$, $0.12{\sim}0.24$, $0.1{\sim}0.25$ and $0.05{\sim}0.10\;cm/s$ of 1.0, 1.4, 2.4 and 3.4 mm of the electrode diameters, respectively. As the reaction time of the enzyme and the substrate was increased, the current was decreased because of the dilution between the sample and buffer solution. Therefore, it could be recommended that the reaction time was able to be selected as shortly as possible in consideration of the total cycle time. As the result of the experiments using a different volume ratio of the enzyme to substrate, it was concluded that the substrate had to be mixed with the same amount of the enzyme. The current have increased remarkably in proportion to the electrode diameter under 0.1 cm/s of the buffer solution velocity but there was no difference over 0.1 cm/s of the buffer solution velocity. The cross type arrangement of the electrode was highly suggested for application and machining of the sensor.

Characterization of Nanopores on Micropillars Pt Electrodes for Non-Enzymatic Electrochemical Sensor Applications

  • Park, Dae-Joon;Lee, Yi-Jae;Park, Jae-Yeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.161-165
    • /
    • 2007
  • In this paper, mesoporous Pt on micro pillars Pt electrode is newly designed, fabricated, and characterized on silicon substrate for non-enzymatic electrochemical sensor micro-chip integrated with CMOS readout circuitry. The fabricated micro/nano Pt electrode has cylindrical hexangular arrayed nano Pt pores with a diameter of 3.2 nm which is formed on top of the micro pillars Pt electrode with approximately $6{\mu}m$ in diameter, $6{\mu}m$ in space, and $50{\mu}m$ in height. The measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $9.9nA/mm^2,\;6.72{\mu}A/mm^2,\;and\;7.67{\mu}A/mm^2$ in 10mM glucose solution with 0.1M phosphate buffered saline (PBS) solution, respectively. In addition, the measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $0.15{\mu}A/mm^2,\;0.56{\mu}A/mm^2,\;and\;0.74{\mu}A/mm^2$ in 0.1mM ascorbic acid (AA) solution with 0.1M phosphate buffered saline (PBS) solution, respectively. This experimental results show that the proposed micro/nano Pt electrode is highly sensitive and promising for CMOS integrated non-enzymatic electrochemical sensor applications. Since the micro-pillar Pt electrode can also be utilized with a micro-fluidic mixer in the sensor chip, the sensor chip can be much smaller, cheaper, and easier to be fabricated.

새로운 전극 설계법을 이용한 인체 감지형 초전형 적외선 센서 시스템 (Human detecting pyroelectric infrared sensor system using new electrode design)

  • 권성열
    • 융합신호처리학회논문지
    • /
    • 제3권4호
    • /
    • pp.74-78
    • /
    • 2002
  • 인체감지용 초전형 적외선 센서 시스템은 최소 2개 이상의 센서를 사용한다. 상부전극과 바닥전극의 디자인을 새로이 하여 센서 2개가 인체감지를 가능하게 하는 센서 시스템을 센서 1개로 구성한 변환기를 설계하였다. 초전성 효과를 나타내는 재료로는 P(VDF/TrFE) 필름을 이용하였다 제작된 적외선 센서는 기존의 2개 이상의 센서를 사용하던 시스템에 비해 거의 같은 결과인 적외선원 13 $\times$ 10$10^-6$ 에 대하여 9.62 $\times$ 10$10^5$ V/W 의 높은 전압감도를 나타내었으며 NEP (noise equivalent power) 는 3.95 $\times$ $10^-7$/ W, 그리고 specific detectivity D$^*$는 5.06 $\times$ $10^5$ cm/W나타내었다.

  • PDF

스크린 인쇄법에 의한 용존 산소센서의 제조 및 특성 (Fabrication of Dissolved Oxygen sensors by Screen Print Method and Characteristic)

  • 정경진;이성필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.926-929
    • /
    • 2003
  • The dissolved oxygen sensor of thick film type was fabricated by screen print method and measured the characteristic, reference electrode used Ag/AgCl, and working electrode used Pt. The devices are continuously powered at potential of $0.7V{\sim}0.8V$ versus Ag/AgCl reference electrode and results indicated that the response characteristic of sensor was $1.002{\mu}A{\sim}19.792{\mu}A$ for thirty seconds. we can know that it is good linearity when compared with of existent dissolved oxygen meter. Therefore sensor fabricated excels sensitivity for dissolved oxygen and will be considered to be applied typically because the price is costly.

  • PDF

유전 알고리듬을 이용한 압전센서의 전극형상 최적화 (Electrode Shape Optimization of Piezo Sensors Using Genetic Algorithm)

  • 이기문;박현철;박철휴
    • 대한기계학회논문집A
    • /
    • 제30권6호
    • /
    • pp.698-704
    • /
    • 2006
  • This paper presents an electrode shape design method for the multi-mode sensors that could deteict the selected structural multiple modes. The structure used for this study is an isotropic cantilever beam type with a PVDF (polyvinylidene fluoride) which is bonded onto the structure as a sensor. The shape optimization problem is solved by using Genetic Algorithm (GA) with an appropriate objective function. The performance of analytical optimal shape sensor is compared with that of experimental work. The results show that the, obtained electrode shape sensors have good performance to detect the multiple vibration modes simultaneously.

전동의수용 근전위 센서 설계 (Design of myoelectrical sensor for myoelectric hand prosthesis)

  • 최기원;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF