• 제목/요약/키워드: Sensor and instruments

검색결과 145건 처리시간 0.025초

Design and Implementation of an Absolute Position Sensor Based on Laser Speckle with Reduced Database

  • Tak, Yoon-Oh;Bandoy, Joseph Vermont B.;Eom, Joo Beom;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.362-369
    • /
    • 2021
  • Absolute position sensors are widely used in machine tools and precision measuring instruments because measurement errors are not accumulated, and position measurements can be performed without initialization. The laser speckle-based absolute position sensor, in particular, has advantages in terms of simple system configuration and high measurement accuracy. Unlike traditional absolute position sensors, it does not require an expensive physical length scale; instead, it uses a laser speckle image database to measure a moving surface position. However, there is a problem that a huge database is required to store information in all positions on the surface. Conversely, reducing the size of the database also decreases the accuracy of position measurements. Therefore, in this paper, we propose a new method to measure the surface position with high precision while reducing the size of the database. We use image stitching and approximation methods to reduce database size and speed up measurements. The absolute position error of the proposed method was about 0.27 ± 0.18 ㎛, and the average measurement time was 25 ms.

Electrochemical Monitoring of NADH Redox with NPQD-modified Electrodes for Cell Viability Assessment

  • JuKyung Lee;Hye Bin Park;Chae Won Seo;Chae Won Seo;SangHee Kim
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.412-417
    • /
    • 2023
  • There is increasing interest in the rapid and highly sensitive monitoring of cell viability in biological and toxicological research. Conventional methods depend on optical assays using Water Soluble Tetrazolium-8 (WST-8) or 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay, which requires a large volume of samples and special instruments, necessitating shipment of clinical samples to laboratories. This paper reports on the development of a rapid and sensitive electrochemical (EC) sensor using screen printed electrode (SPE) and surface modification using 4'-mercapto-N-phenylquinone diamine (4'-NPQD), as double electron mediators, for monitoring cell viability via the measurement of nicotinamide adenine dinucleotide (NADH). We used the sensor to observe the viability of MCF-7 and doxorubicin (Dox)-treated cells. The oxidation current of NADH was measured via chronoamperometry (CA), and the EC results showed a good linear relationship when compared with NADH quantification using WST-8 assay. The analysis time was only 10 s and limit of detection (LOD) of NADH was 1.78 µM. Our EC method has the potential to replace conventional WST assays for cell viability and cytotoxicity experiments.

고속철도용 판토그라프 접촉력 측정을 위한 스트레인 게이지 내장형 하중센서 개발 (Development of Force Sensor to Measure Contact Force of Pantograph for High-Speed Train)

  • 박찬경;김영국;조용현;백진성
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.488-492
    • /
    • 2010
  • 과거부터 고속전철 및 집전시스템과 같은 핵심 주요 시스템에 대한 성능을 검증하기 위한 정교한 시험방법과 평가절차는 국내외의 전문가들을 통해 연구되어져 왔다. 판토그라프의 접촉력 측정 하중센서는 판토그라프의 특성에 따라 특수제작이 필요하다. 본 논문에서는 판토그라프와 가선시스템 간의 상호작용 특성을 평가하기 위한 항목인 접촉력을 측정하는 방법을 개선하기 위하여 개발된 스트레인 게이지 내장형 하중센서를 소개하고자 한다. 판토그라프에 직접 설치하여 수행한 정적 및 동적 검증의 결과는 매우 신뢰성을 가지고 있어 향후 고속전철용 판토그라프의 보다 효율적인 집전특성을 평가하기 위한 측정시스템의 일부로 활용될 수 있을 것이다.

CTD 교정 시스템 구축 및 불확도 평가 (Establishment of CTD Calibration System and Uncertainty Estimation)

  • 이정한;황근춘;김은수;이승훈
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

임상병리검사를 위한 모바일 에이전트 기반의 바이오로봇 시스템 개발 (Development of BioRobot System Based on Mobile Agent for Clinical Laboratory)

  • 최병준;진성문;신승훈;구자춘;김민철;김진현;손웅희;안기탁;정완균;최혁렬
    • 로봇학회논문지
    • /
    • 제2권4호
    • /
    • pp.317-326
    • /
    • 2007
  • Recently, robotic automation in clinical laboratory becomes of keen interest as a fusion of bio and robotic technology. In this paper, we present a new robotic platform for clinical tests suitable for small or medium sized laboratories using mobile robots. The mobile robot called Mobile Agent is designed as transfer system of blood samples, reagents, microplates, and any instruments. Also, the developed mobile agent can perform diverse tests simultaneously based on its cooperative and distributed ability. The driving circuits for the mobile agent are embedded in the robot, and each mobile agent communicates with other agents by using Bluetooth communication. The RFID system is used to recognize patient information. Also, the magnetic hall sensor is embedded to remove and compensate the cumulated error of locomotion at the bottom of mobile agent. The proposed mobile agent can be easily used for various applications because it is designed to be compatible with general software development tools. The Mobile agents are manufactured, and feasibility of the robot and localization of the agents using magnetic hall sensor are validated by preliminary experiments.

  • PDF

대관령 구름물리관측시스템 산출물 평가 및 FSSP를 이용한 시정환산 시험연구 (Intercomparison of Daegwallyeong Cloud Physics Observation System (CPOS) Products and the Visibility Calculation by the FSSP Size Distribution during 2006-2008)

  • 양하영;정진임;장기호;차주완;정재원;김유철;이명주;배진영;강선영;김금란;최영진;최치영
    • 대한원격탐사학회지
    • /
    • 제26권2호
    • /
    • pp.65-73
    • /
    • 2010
  • 구름과 강수특성을 분석하기 위해 대관령에 구름물리관측시스템(Cloud physics Observation System, 이하 CPOS)을 2003년부터 운영해 오고 있다. 주요 관측 기기는 다음과 같다: FSSP (Forward Scattering Spectrometer Probe), OPC (Optical Particle Counter), VS (Visibility Sensor), PARSIVEL disdrometer, MWR (Microwave Radiometer), MRR (Micro Rain Radar). 앞의 4개 장비는 지상구름 (안개)과 강수 특성을, 뒤의 2개 장비는 연직구름의 특성을 실시간으로 관측하고 있다. CPOS 산출물을 검증하기 위해 FSSP는 흡습성 물질 시딩 실험 중 OPC와, MWR의 가강수량은 라디오존데와, PARSIVEL과 MRR은 우량계와 비교 연구가 수행되었다. 그 결과를 보면 대부분이 0.7이상의 좋은 상관도를 보인다. 이와 같이 신뢰도를 확보한 CPOS 관측 자료는 구름과 에어로솔의 간접효과나 기상조절 실험에 유용한 자료로 활용될 수 있을 것이다. FSSP의 입자 크기 분포를 시정값으로 환산해 보았으며 FSSP 환산 시정값은 visibility sensors (SVS)와 PWD22 (Present Weather Detect 22)의 시정계 값에 비해 1.7~1.9배 과도한 경향을 보였다. 이는 FSSP에 의해 관측되는 입자 크기($2{\sim}47\;{\mu}m$)의 한계 때문으로 사료된다. 향후 다른 입자크기분포를 측정할 수 있는 장비를 도입하여 추가 분석을 추진할 계획이다.

Radiation effect on the polymer-based capacitive relative humidity sensors

  • Shchemerov, I.V.;Legotin, S.A.;Lagov, P.B.;Pavlov, Y.S.;Tapero, K.I.;Petrov, A.S.;Sidelev, A.V.;Stolbunov, V.S.;Kulevoy, T.V.;Letovaltseva, M.E.;Murashev, V.N.;Konovalov, M.P.;Kirilov, V.N.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2871-2876
    • /
    • 2022
  • The sensitivity of polymer-based capacitive relative humidity (RH) sensors after irradiation with neutrons, electrons and protons was measured. Degradation consists of the decreasing of the upper RH limit that can be measured. At the same time, low RH-level sensitivity is almost stable. After 30 krad of absorption dose, RH cut off is equal to 85% of max value, after 60 krad-40%. Degradation reduces after annealing which indicates high radiation sensitivity of the internal circuit in comparison to RH-sensing polymer film.

NMEA2000을 이용한 임베디드 선박 모니터링 시스템의 개발 (Development of Embedded Vessel Monitoring System Using NMEA2000)

  • 이창의;김달용;유영호;신옥근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.746-755
    • /
    • 2009
  • Recently, NMEA2000 became the de facto standard of the communication protocol for the instrument level network in vessels, and it is anticipated that most of the vessels will be equipped with the sensors and actuators based on this protocol. The conventional serial communication specifications such as RS-232, RS-485, or even NMEA0183 are single-talker/multiple-listener and interconnection among multiple sensors and/or actuators usually results in a bundle of wires. On the other hand, NMEA2000 is a true bus type(multiple-talker/multiple-listener) protocol and theoretically up to 256 instruments can be hot-plugged. With the advent of the protocol, it is necessary to consider a new type of monitoring system for the instruments in vessels: In most traditional serial communication environments, a dedicated monitor or user interface was necessary for each sensor or actuator as it was simply not easy to collect data in a single place. With NMEA2000, the collection of various types of information is simple. An embedded system can be employed to combine, to arrange and to display informations from various types of devices. Assuming that the actuators and sensors on a vessel are interconnected by NMEA2000 standard, we devise a tentative interactive vessel monitoring system in which the following 4 kinds of informations are collected and delivered: the navigation, engine, weather and tanks informations.

온라인 수질 감시 시스템의 개발 (Development of On-line Water Quality Monitoring System)

  • 김재철;이재윤;박종식;권우현;김승호;이찬원
    • 센서학회지
    • /
    • 제5권3호
    • /
    • pp.75-85
    • /
    • 1996
  • 본 논문에서는 실시간으로 수질을 감시하기 위한 온라인 감시시스템을 개발하였다. 개발된 시스템은 중앙 감시 제어부, 데이타 수집기 및 단위 오염 성분 측정기들로 구성되며, 이들을 계층적인 구조로 체계적으로 결합시켜 융통성과 확장성을 가지도록하여 효율적인 데이타 수집 및 관리가 이루어지도록 하였다. 또한 수질측정의 기본이 되는 물의 염도, 전기전도도, 온도, 용존산소량 및 대장균 측정기를 원격 무인 측정이 가능하도록 설계 제작하였다.

  • PDF

정확한 평면운동 측정을 위한 광 변위센서의 성능분석 (Performance analysis of the optical displacement sensor for accurate in-plane motion measurement)

  • 강훈;이헌석;오진석
    • 한국정보통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.639-646
    • /
    • 2016
  • 본 연구에서는 특수한 상황(미끄러짐 발생 및 회전관성이 부하로 작용하는 경우)에서의 회전 엔코더 기반 측정방법의 단점을 극복하기 위하여 광 변위센서(ADNS-9500)를 사용한 비접촉식 변위 측정방법을 제안하였다. 정확한 변위 측정을 위해 데이터 수집 보드와 랩뷰를 활용하여 실험적으로 광 변위센서의 성능을 분석하였으며, 반복실험을 통해 실험조건(측정방향, 속도, 가속도, 높이, 표면 재질)에 따른 광 변위센서의 성능특성을 파악하였다. 성능실험 결과, 광 변위센서를 사용하여 정확하게 평면운동을 측정하기 위해서는 광 변위센서와 지면(대상 물체의 표면)과의 높이를 2.4 mm-3.2 mm로 일정하게 유지시켜야 하며, 각각의 축 방향, 속도, 표면 재질을 고려하여 민감도를 수정하여 변위 계산식에 적용해야 하는 것을 확인하였다.