• 제목/요약/키워드: Sensitivity Margin

검색결과 133건 처리시간 0.025초

원자로구조물의 지진응답 민감도해석 (Sensitivity Analysis on the Seismic Responses of the Reactor Structures)

  • 이재한;김종범;구경회;김종인;유봉;최순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.183-190
    • /
    • 1993
  • The seismic response of the reactor structures depends on the dynamic charact-eristics of the structures and the input earthquake loadings. The stuctural integ-rity of the reactor internal components can be verified by the dynamic response analyses to implement the effects of the design loadings like earthquakes. The sensitivity analyses of the dynamic characteristics for the analytical model of reactor structures considering the possible variations of the stiffnesses of the CSB upper flange and the snubber were performed to improve the dynamic characteri-stics of the structures against seismic loading. And to enhance the structural design margin of the reactor internal components the nonlinear time history analyses were attempted for the modified analytical model, and the results were compared between the reference model and the modified ones.

  • PDF

신 자기회로가 적용된 광픽업 액추에이터의 동특성 (Dynamic characteristics of optical pickup actuator with a newly designed electromagnetic circuit)

  • 박관우;김재은;정제현;이경택;고의석;민병훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.512-514
    • /
    • 2008
  • In this paper, a new electromagnetic circuit is proposed for an optical pickup actuator with high sensitivity. Contrary to those of conventional actuators, the proposed circuit has two focusing coils which are diagonally placed at the front and rear of a moving part. The configuration which makes the effective length of the focusing coil longer and the moving part lighter, is helpful in increasing the sensitivity of the actuator. However, the asymmetry of the moving part by two focusing coils causes flexible node vibrations in quite low frequency range. This paper shows that the design modification of the moving part for the reconfiguration of mass moment of inertia can reduce the mode vibrations.

  • PDF

DDM Rotordynamic Design Sensitivity Analysis of an APU Turbogenerator Having a Spline Shaft Connection

  • Lee, An-Sung;Ha, Jin-Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.57-63
    • /
    • 2003
  • An eigenvalue design sensitivity formulation of a general nonsymmetric-matrix rotor-bearing system is devised. using the DDM (direct differential method). Then, investigations on the design sensitivities of critical speeds are carried out for an APU turbogenerator with a spline shaft connection. Results show that the dependence of the rate of change of the critical speed on the stiffness changes of bearing models of spline shaft connection points is negligible, and thereby their modeling uncertainty does not present any problem. And the passing critical speeds up to the 4th critical speed are not sensitive to the design stiffness coefficients of four main bearings. Further, the dependence of the rate of change of the critical speed on the shaft-element length changes shows quantitatively that the spline shaft has some limited influence on the 4th critical speed but no influence on the 1st to 3rd critical speeds. With no adverse effect from the spline shaft, the APU system achieves a critical speed separation margin of more than 40% at a rated speed of 60,000 rpm.

Intra-Operative Frozen Sections: Experience at A Tertiary Care Centre

  • Preeti, Agarwal;Sameer, Gupta;Kulranjan, Singh;Abhinav, Sonkar Arun;Preeti, Rani;Sunita, Yadav;Mati, Goel Madhu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권12호
    • /
    • pp.5057-5061
    • /
    • 2016
  • The present study was conducted to assess error rates with diagnosis using intra-operative frozen sections, and to indicate ways to increase overall performance. Over a period of two years, 227 cases were biopsied intra-operatively. Errors were observed in 14 cases. Four of these were sampling errors, one by a pathologist and three by surgeons. In seven cases incorrect interpretations were made. Epithelial dysplasia was observed on definitive histology in two cases which was not reported intra-operatively. One case was of ectopic thyroid. In cases of oral cancer where sentinel lymph nodes were sampled, immunohistochemistry for cytokeratin was performed to facilitate identification of micrometastasis. Only single case displayed tumor deposits which was not evident morphologically. Resection margins were reported in seventy eight cases. Some 18% (14/50) benefited from revision of margins; overall sensitivity of intra-operative frozen sections for marginal status was 71.4%, with a specificity of 90.3%. Overall sensitivity was 75% and specificity was 97.5%. Careful observation, pathologist experience and knowledge of limitations help in improving the overall diagnostic outcome.

A SENSITIVITY STUDY ON NEUTRONIC PROPERTIES OF DUPIC FUEL

  • Park, Hangbok;Roh, Gyu-Hog
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.124-129
    • /
    • 1998
  • A sensitivity study has been done to determine the composition of DUPIC fuel from the viewpoint of neutronics fuel design. The spent PWR fuel compositions were generated and fissile contents adjusted by blending fresh uranium after mixing two spent PWR fuel assemblies. The $^{239}$ Pu and $^{235}$ U enrichments of DUPIC fuel were adjusted by controlling the amount of fresh uranium feed and the ratio of slightly enriched and depleted uranium in the fled uranium. Based on the material balance calculation, it is recommended that DUPIC fuel composition be such that spent PWR fuel utilization is more than 90%.. A sensitivity study on the temperature reactivity coefficient of DUPIC fuel has shown that it is desirable to increase the $^{239}$ Pu and $^{235}$ U contents to reduce both the fuel and coolant temperature coefficients. On the other hand, refueling simulations of the DUPIC core have shown that the channel power peaking factor, which is a measure of the reactor trip margin, increases with the total fissile content. Considering these neutronic characteristics of the DUPIC fuel, il is recommended to have enrichments of 0.45 and 1.00 wt% for $^{239}$ Pu and $^{235}$ U, respectively.

  • PDF

복부 초음파검사에서 영상 점수 시스템 분류에 따른 간 섬유화 평가의 유용성 (Usefulness of Liver Fibrosis According to Classification of Image Score System In Abdominal Ultrasonography)

  • 안현;지태정;이효영;임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.187-194
    • /
    • 2019
  • The purpose of this study was to evaluate the pathologic results of hepatic parenchyma parameters such as liver parenchyma, liver surface, liver margin and liver, portal vein, spleen size, And to evaluate the usefulness of fibrosis progression and hepatic ultrasonography. The sensitivity, specificity, positive predictive value, and prognostic value according to the stage of fibrosis and grade of inflammation were divided into two groups according to the morphologic variable "A" through ultrasound and "B" We evaluated the predictive value and predicted the variables to evaluate fibrosis in clinical diagnosis and treatment of patients with chronic liver disease. The sensitivity and specificity of hepatic fibrosis in hepatic morphologic variables and other size variables were highest in liver surface and edge. The morphologic parameters used in the evaluation of fibrosis were clinically relevant in distinguishing the fibrosis stage from the results of liver biopsy.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

정지궤도위성 X-대역 출력필터 멀티팩션 민감도 해석 (Multipaction Sensitivity Analysis of X-band Output Filter for Geostationary Satellite)

  • 김중표;이선익;임원규;김상구;이상곤
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.131-136
    • /
    • 2015
  • 본 논문에서는 정지궤도위성 관측탑재체 고속 데이터 전송을 위한 X-대역 이중모드 원통형 고전력 전송 출력필터의 비행모델 개발 이전에 개발 모델을 설계하고 해석적 멀티팩션 요구마진을 보장하기 위해 해석되어졌다. 먼저 멀티팩션에 가장 민감한 슬롯 아이리스의 폭 및 두께를 가변하면서 멀티팩션 발생 임계전력의 민감도를 분석하였으며 그것을 토대로 선정된 아이리스 폭 및 두께에 대한 주파수 대역에 따른 멀티팩션 임계전력을 분석하였으며 대역 내에서 해석적 요구 8 dB 마진을 가짐을 확인하였다. 또한 멀티팩션과 함께 고출력 소자에 중요한 코로나 발생 임계전력 분석을 아이리스 폭 및 두께의 영향을 제시하였다. 마지막으로 제작된 개발모델을 시험한 결과 주요 요구사항을 만족함을 확인하였다.

Increasing Profitability of the Halal Cosmetics Industry using Configuration Modelling based on Indonesian and Malaysian Markets

  • Dalir, Sara;Olya, Hossein GT;Al-Ansi, Amr;Rahim, Alina Abdul;Lee, Hee-Yul
    • Journal of Korea Trade
    • /
    • 제24권8호
    • /
    • pp.81-100
    • /
    • 2020
  • Purpose - Based on complexity theory, this study develops a configurational model to predict the profitability of Halal cosmetics firms in the Indonesian and Malaysian markets. The proposed research model involves two level configurations-industry context and selling strategies-to predict high and low scores of a firm's profitability. The industry context configuration model comprises industry stability, product homogeneity, price sensitivity, and switching cost. Selling strategies include customer-focused, competitor-focused, and margin-focused approaches. Design/methodology - This is the first empirical study that calculates causal models using a combination of industry context and selling strategy factors to predict profitability. Data obtained from the marketing managers of cosmetics firms are used to test the proposed configurational model using fuzzy-set qualitative comparative analysis (fsQCA). It contributes to the current knowledge of business marketing by identifying the factors necessary to achieve profitability using analysis of condition (ANC). Findings - The results revealed that unique and distinct models explain the conditions for high and low profitability in the Indonesian and Malaysian halal cosmetic markets. While customer-focused selling strategy is necessary to attain a higher profit in both the markets, margin-focused selling strategy appears to be an essential factor only in Malaysia. Complexity of the interactions of selling strategies with industry factors and differences between across two study markets confirmed that complexity theory can support the research configurational model. The theoretical and practical implications are also illustrated. Originality/value - Despite the rapid growth of the global halal industry, there is little knowledge about the halal cosmetic market. This study contributes to the current literature of the halal market by performing a set of asymmetric analytical approaches using a complex theoretical model. It also deepens our understating of how the Korean firms can approach the Muslim consumer's needs to generate more beneficial turnover/revenue.

단일 입출력 시스템에 대한 IMC-PID의 새로운 최적 동조법 (New Optimal Tuning Method of IMC-PID for SI/SO Systems)

  • 김창현;임동규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.213-217
    • /
    • 2008
  • 본 논문에서는 표준 IMC-PID 제어기에 시스템 식별상의 위상 조절 인자를 설계 변수로 추가함으로 새로운 IMC-PID 제어기 설계 방법을 제안한다. 제안된 제어기의 동조법으로 해석적으로 구해진 주파수 영역 특성을 통해 주파수 영역 성능을 보장하도록 하는 설계 변수의 구속 조건 하에서 시간영역의 적분 오차 지표를 가격함수로 최소화하는 최적 해를 얻는다. 이 제안된 동조법은 다양한 설계 사양을 동시에 고려하도록 하여 기존의 IMC-PID의 단일 설계 변수 동조가 갖는 비유연성 문제를 개선하였다. 사례 연구에서 기존의 동조법들과의 성능 비교를 통해 그 유용성을 검토했다.

  • PDF