• Title/Summary/Keyword: Sensitivity Correction

Search Result 173, Processing Time 0.024 seconds

Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction (핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정)

  • Kim, Jin-Su;Lee, Jae-Sung;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

A Perception-based Color Correction Method for Multi-view Images

  • Shao, Feng;Jiang, Gangyi;Yu, Mei;Peng, Zongju
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.2
    • /
    • pp.390-407
    • /
    • 2011
  • Three-dimensional (3D) video technologies are becoming increasingly popular, as it can provide users with high quality and immersive experiences. However, color inconsistency between the camera views is an urgent problem to be solved in multi-view imaging. In this paper, a perception-based color correction method for multi-view images is proposed. In the proposed method, human visual sensitivity (VS) and visual attention (VA) models are incorporated into the correction process. Firstly, the VS property is used to reduce the computational complexity by removing these visual insensitive regions. Secondly, the VA property is used to improve the perceptual quality of local VA regions by performing VA-dependent color correction. Experimental results show that compared with other color correction methods, the proposed method can greatly promote the perceptual quality of local VA regions greatly and reduce the computational complexity, and obtain higher coding performance.

Sensitivity of the Eigenvalues of Beams to the Change of Element Correction Factors (유한요소의 수정계수 변화에 대한 보 고유치의 민감도)

  • Lee, Gun-Myung
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1678-1683
    • /
    • 2003
  • Some characteristics of the sensitivities of the eigenvalues for beams have been found in the paper. For cantilever beams and simply supported beams, the sensitivities of the eigenvalues to the stiffness correction factor of one element are equal and opposite to the sensitivities to the mass correction factor of the symmetrically positioned element. The relationship means that to increase stiffness in one element has the same effects on the eigenvalues as to decrease mass by the same proportion in the symmetrically positioned element. For beams with other boundary conditions, however, the relationship does not hold.

  • PDF

Position Correction Algorithm of Door Mounting Robot based on Door-Chassis Gap Sleasure (도어-차체 틈새 측정에 근거한 도어 장착 로보트의 위치 보정 알고리즘 개발)

  • 김미경;강희준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.565-570
    • /
    • 1994
  • This work deals with finding a suitable position correction algorithm of industrial robot based on measuring gaps between door and chassis. The algorithm calculates correction quantities and then must allow visually acceptable door-chassis assembly take. The algorithm simulation is performed for a simple door-chassis model, and its effectiveness is addressed in terms of the predefined total unformity, line uniformity. In addition, the error sensitivity analysis of the rotation center of door due to the mismatch of robot grasping is performed using the algorithm.

  • PDF

Sensitivity analysis of satellite-retrieved SST using IR data from COMS/MI

  • Park, Eun-Bin;Han, Kyung-Soo;Ryu, Jae-Hyun;Lee, Chang-Suk
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.6
    • /
    • pp.589-593
    • /
    • 2013
  • Sea Surface Temperature (SST) is the temperature close to the ocean's surface and affects the Earth's atmosphere as an important parameter for the climate circulation and change. The SST from satellite still has biases from the error in specifying retrieval coefficients from either forward modeling or instrumental biases. So in this paper, we performed sensitivity analysis using input parameter of the SST to notice that the SST is most affected among the input parameter. We used Infrared (IR) data from the Communication, Ocean, and Meteorological Satellite (COMS)/Meteorological Imager (MI) from April 2011 to March 2012. We also used the Global Space-based Inter-Calibration System (GSICS) correction to quality of the IR data from COMS. SST was calculated by substituting the input parameters; IR data with or without the GSICS correction. The results of this sensitivity analysis, the SST was sensitive from -0.0403 to 0.2743 K when the IR data were changed by the GSICS corrections.

A Projection-based Intensity Correction Method of Phased-Array Coil Images (위상 배열 코일 영상에서의 밝기 비균등성을 projection에 기반하여 수정하는 방법)

  • Yun SungDae;Chung Jun-Young;Han YeJi;Park HyunWook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Purpose : To develop a novel approach to calculate the sensitivity profiles of the phased array coil for use in non-uniform intensity correction. Materials and Methods : The proposed intensity correction method estimates the sensitivity profile of the coil to extract intensity variations that represent the scanned image. The sensitivity profile is estimated by fitting a non-linear curve to various angles of projections through the imaged object in order to eliminate the high-frequency image content. Filtered back projection is then used to compute the estimates of the sensitivity profile of each coil. The method was applied both to phantom and brain images from 8-channel phased-array coil and 4-channel phased-array coil, respectively. Results : Intensity-corrected images from the proposed method have more uniform intensity than those from the commonly used 'sum-of-squares' approach. By using the proposed correction method, the intensity variation was reduced to $6.1\%$ from $13.1\%$, acquired from the 'sum-of-squares'. Conclusion : The proposed method is more effective at correcting the intensity non-uniformity of the phased-array surface-coil images than the conventional 'sum-of-squares' method.

  • PDF

Characteristics of the Eigenvalue Sensitivities to the Change of Element Correction Factors for Beams

  • Lee, Gun-Myung;Park, Young-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.955-960
    • /
    • 2004
  • Some characteristics of the eigenvalue sensitivities have been found for beams in the paper. For cantilever beams and simply supported beams, the sensitivities of the eigenvalues to the stiffness correction factor of one element are equal and opposite to the sensitivities to the mass correction factor of the symmetrically positioned element. For beams with other boundary conditions, however, the relationship does not hold. The relationship has been proven analytically for simply supported beams.

An improvement of Simplified Atmospheric Correction : MODIS Visible Channel

  • Lee, Chang-Suk;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.6
    • /
    • pp.487-499
    • /
    • 2009
  • Atmospheric correction of satellite measurements is a major step to estimate accurate surface reflectance of solar spectrum channels. In this study, Simplified Method for the Atmospheric Correction (SMAC) radiative transfer model used to retrieve surface reflectance from MODIS (MODerate resolution Imaging Spectrometer) top of atmosphere (TOA) reflectance. It is fast and simple atmospheric correction method, so it uses for work site operation in various satellite. This study attempts a test of accuracy of SMAC through a sensitivity test to detected error sources and to improve accuracy of surface reflectance using SMAC. The results of SMAC as compared with MODIS surface reflectance (MOD09) was represented that low accuracy ($R^2\;=\;0.6196$, Root Means Square Error (RMSE) = 0.00031, bias = - 0.0859). Thus sensitivity analysis of input parameters and coefficients was conducted to searching error sources. Among the input parameters, Aerosol Optical Depth (AOD) is the most influence input parameter. In order to modify AOD term in SMAC code, Stepwise multiple regression was performed with testing and remove variable in three stages with independent variables of AOD at 550nm, solar zenith angle, viewing zenith angle. Surface reflectance estimation by using Newly proposed AOD term in the study showed that improve accuracy ($R^2\;=\;0.827$, RMSE = 0.00672, bias = - 0.000762).

Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors (유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가)

  • Seong-Yun Mok;Yeong-Rok Kang;Hyo-Jin Kim;Yong-Uk Kye;Hyun An
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

DEVELOPMENT OF CALCULATION METHOD OF SENSITIVITIES FOR LIGHT WATER REACTORS

  • Takeda, Toshikazu;Foad, Basma
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.753-758
    • /
    • 2013
  • A new method of calculating sensitivity coefficients of core characteristics relative to infinite-dilution cross sections has been developed. Conventional sensitivity coefficients are evaluated for the changes of effective cross sections which are dependent on individual models of core and cell. Therefore a correction has been derived to the conventional sensitivity coefficients based on the perturbation theory. The accuracy of the present method has been verified by comparing numerical results of sensitivity coefficients with a reference Monte-Carlo method.