• 제목/요약/키워드: Sensitive Loads

검색결과 191건 처리시간 0.028초

신기술 보급 및 DSM 정책이 부하기기 학습곡선에 미치는 영향 (The Influence of Introducing New Technologies and DSM Strategies on End-Use Learning Curves)

  • 황성욱;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.435-437
    • /
    • 2001
  • The change of the electricity charge from cost base to price base due to the introduction of the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Besides, it is required the index that consolidate the price volatility experienced on the power exchange with gaming and strategic bidding by suppliers to increase profits. Therefore, in order to find a mathematical model of the sensitively-responding-to-price loads, the price-sensitive load model is needed. And the development of state-of-the-art technologies affects the electricity price, so the diffusion of high-efficient end-uses and these price affect load patterns. This paper shows the analysis on learning curves algorithms which is used to investigate the correlation of the end-uses' price and load patterns.

  • PDF

특수수용가의 고조파전압 왜형현황과 고조파 관리 방안 (Harmonic Distortion Level of Special loads and Method of Harmonic Distortion Management)

  • 황치우;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.875-877
    • /
    • 1997
  • Due to the development of electric energy conversion technology and need for energy saving most of the electric machinery and equipments are using power semiconductor switching elements, On the contrary semiconductor switching device is more sensitive to the voltage instability and voltage distortion. In order to manage the voltage distortion following foundation should be settled down in advance. First, reasonable and objective technical guidelines should be established. Second, monitoring network for power quality should be operated. In this paper measurement results of the harmonic distortion of the special loads are given and method for harmonic pollution management is discussed.

  • PDF

반주기 슬라이딩 윈도우와 재귀적 실효치 계산을 이용한 국내 플리커 평가지수 산출기법 (Equivalent 10-Hz Flicker Index Calculation Using Half-cycle Sliding Window and Recursive RMS Method)

  • 조수환
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2017-2020
    • /
    • 2011
  • Flicker, which is also known as voltage fluctuation, is an electromagnetic phenomenon generated by large scale nonlinear loads, such as arc furnaces and welding machines. Since a severe and continuous flicker can cause to some damages to electrically sensitive loads as well as human's visual irritations, it needs to be appropriately managed by being accurately measured, quantified and assessed. In Korea, an equivalent 10-Hz flicker index, shortly ${\Delta}V10$, is used to determine the permission limit of flicker. This paper presents an efficient calculation of the flicker index by using a half-cycle sliding window and a recursive method, showing a concrete calculating procedure of ${\Delta}V10$ from the viewpoint of signal processing.

SWMM과 WASP5모형을 이용한 간척지 담수호의 수질거동 특성 조사 (Behavior of Water Quality in Freshwater Lake of Tide Reclaimed Area Using SWMM and WASP5 Models)

  • 김선주;김성준;이석호;이준우
    • 한국농공학회지
    • /
    • 제44권2호
    • /
    • pp.148-160
    • /
    • 2002
  • Lake water quality assessment information is useful to anyone involved in lake management, from lakeshore owners to lake associations. 11 provides lake water quality, which can improve how to manage lake resources and how to measure current conditions. It also provides a knowledge base that can be used to protect and restore lakes. SWMM was applied to simulate the discharge and pollutant loads from Boryeong watershed, and WASP5 was applied to analyze the changes of water quality in Boryeong freshwater lake. In each model, the most suitable parameters were calculated through sensitive analysis and some parameters used default data. Simulated in SWMM and measured discharge showed the accuracy of 88.6%. T-N and T-P exceeds the criteria in the simulation of water quality in Boryeong freshwater lake, and control of pollutant loads in the main stream showed the most effective way. Integrated water quality management system was developed to give convenience in the operation of SWMM and WASP5 and data acquisition.

Consequence-based robustness assessment of a steel truss bridge

  • Olmati, Pierluigi;Gkoumas, Konstantinos;Brando, Francesca;Cao, Liling
    • Steel and Composite Structures
    • /
    • 제14권4호
    • /
    • pp.379-395
    • /
    • 2013
  • Aim of this paper is to apply to a steel truss bridge a methodology that takes into account the consequences of extreme loads on structures, focusing on the influence that the loss of primary elements has on the structural load bearing capacity. In this context, the topic of structural robustness, intended as the capacity of a structure to withstand damages without suffering disproportionate response to the triggering causes while maintaining an assigned level of performance, becomes relevant. In the first part of this study, a brief literature review of the topics of structural robustness, collapse resistance and progressive collapse takes place, focusing on steel structures. In the second part, a procedure for the evaluation of the structural response and robustness of skeletal structures under impact loads is presented and tested in simple structures. Following that, an application focuses on a case study bridge, the extensively studied I-35W Minneapolis steel truss bridge. The bridge, which had a structural design particularly sensitive to extreme loads, recently collapsed for a series of other reasons, in part still under investigation. The applied method aims, in addition to the robustness assessment, at increasing the collapse resistance of the structure by testing alternative designs.

트레드밀 달리기시 신발 내부의 부하에 관한 연구 (In-shoe Loads during Treadmill Running)

  • 이기광
    • 한국운동역학회지
    • /
    • 제14권2호
    • /
    • pp.105-119
    • /
    • 2004
  • To enhance our understanding of the loads on the foot during treadmill running, we have used a pressure-sensitive insole system to determine pressure, rate of loading and impulse distributions on the plantar surface during treadmill running, both in minimally cushioned footwear and in cushioned shoes. This report includes pressure, rate of loading, impulse and contact time data from a study of ten subjects running on a treadmill at 4.0m/s. Among heel-toe runners, the highest peak pressures and highest rates of loading were observed under the centre of the heel and in the medial forefoot. The arch regions were only lightly loaded. Contact time was greater in the forefoot than in the heel. Two-thirds of the impulse recorded during the step was the result of forces applied through the forefoot, mostly in the region of the metatarsal heads. The distribution of loads in the shoe suggests that the load distributing properties of the cushioning system are most important in the centre of the heel, under the metatarsal heads and great toe. Shock attenuation is primarily required under the centre of the heel and to lesser extent under the metatarsal heads. Some energy dissipation may be desirable in the heel region because it causes shock to be absorbed with less force. All the 'propulsive' effort is applied through the forefoot. Therefore, this region should as resilient as possible.

빌딩용 직류배전 시스템의 3상 AC/DC 컨버터의 기동 시 과도상태 응답 개선 (Transient Response Improvement at Startup of Three Phase AC/DC Converter for DC Distribution System in Building Applications)

  • 신수철;이희준;이정효;나종국;원충연
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.138-144
    • /
    • 2013
  • Most of the DC loads have had the sensitive characteristics electrically for input voltage. In this system, power converter is operated after connecting with DC loads to minimize the overshoot of the control voltage that may occur during connection of the loads. But whenever starting the power converter, parameters in circuit are different because power converter has been connected with diverse load types at each startup time. This is cause of a disadvantage to PI controller design of power converter. In this paper, the novel voltage control method using sliding mode control theory has proposed. This control method minimizes the overshoot of control voltage at startup of power converter. Despite the variations of the system parameters, the proposed voltage controller has fast response and robustness characteristics such as PI and sliding mode controllers. The proposed controller was applied to the three-phase AC/DC converter and each performance of controller was verified.

사무용 건축물 공조설비 설계도서 분석 (Analysis of Office Building HVAC System Drawings)

  • 박종일;김세환;김동규
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.776-781
    • /
    • 2007
  • Optimized capacity of equipments are essential for energy saving and low cost construction and operation. So we must use proper design data for HVAC system design. We investigated for architectural data, equipment capacity, cooling and heating load design criteria of 52 office buildings. Following research results were obtained by carrying out each task. Office building effective area rate is 63%. The average building cooling load of South Korea is $140W/m^2$ and average heating loads in Seoul and Pusan area are $120{\sim}130W/m^2$ and $70{\sim}80W/m^2$. We also analysised HVAC design criteria. Person ratio in effective building area is $0.2person/m^2$, sensitive and latent heat loads of a person are 60W and 65W, light and equipment loads of office buildings are $25W/m^2$ and $20W/m^2$.

개인용 컴퓨터 부하의 직렬동조필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구 (A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads)

  • 서범관;김경철;이일무
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.36-41
    • /
    • 2006
  • 컴퓨터 부하는 현대사회 전반에 널리 사용되고 있다. 개인용 컴퓨터의 스위칭 모드 전원공급 장치는 고조파 전류를 발생시키는 주된 발생원이다. 고조파 전류는 컴퓨터 오동작등 많은 고조파 장해를 일으킨다. 직렬동조필터는 개인용 컴퓨터의 고조파 저감에 매우 효과적이다. 순간전압강하는 전압의 크기가 짧은 시간동안 감소하는 것으로, 순간전압의 변동원인은 주로 계통의 고장, 급격한 부하변동 등으로 발생한다. 컴퓨터 부하는 전압강하에 민감한 것으로 알려져 있다. 본 논문에서는 개인용 컴퓨터 부하에 직렬동조필터를 적용하였을 때 고조파 저감효과를 IEC 61000-3-2로 평가하였고, 순간전압강하 영향을 ITI 곡선으로 심도있게 분석하였다.

A Kalman filter based algorithm for wind load estimation on high-rise buildings

  • Zhi, Lun-hai;Yu, Pan;Tu, Jian-wei;Chen, Bo;Li, Yong-gui
    • Structural Engineering and Mechanics
    • /
    • 제64권4호
    • /
    • pp.449-459
    • /
    • 2017
  • High-rise buildings are generally sensitive to strong winds. The evaluation of wind loads for the structural design, structural health monitoring (SHM), and vibration control of high-rise buildings is of primary importance. Nevertheless, it is difficult or even infeasible to measure the wind loads on an existing building directly. In this regard, a new inverse method for evaluating wind loads on high-rise buildings is developed in this study based on a discrete-time Kalman filter. The unknown structural responses are identified in conjunction with the wind loads on the basis of limited structural response measurements. The algorithm is applicable for estimating wind loads using different types of wind-induced response. The performance of the method is comprehensively investigated based on wind tunnel testing results of two high-rise buildings with typical external shapes. The stability of the proposed algorithm is evaluated. Furthermore, the effects of crucial factors such as cross-section shapes of building, the wind-induced response type, errors of structural modal parameters, covariance matrix of noise, noise levels in the response measurements and number of vibration modes on the identification accuracy are examined through a detailed parametric study. The research outputs of the proposed study will provide valuable information to enhance our understanding of the effects of wind on high-rise buildings and improve codes of practice.