상대압 용량성 압력센서의 제작 (Fabrication of Relative-type Capacitive Pressure Sensor)

  • 서희돈;임근배;최세곤
    • 전자공학회논문지A
    • /
    • 제30A권7호
    • /
    • pp.82-88
    • /
    • 1993
  • This paper describes fabrication of relative type capacitive pressure sensor to be in great demand for many fields. The fabricated sensor consists of two parts` a sensing diaphragm and a pyrox glass cover. The sensor size is 4.5${\times}3.4mm$^{2})$ and 400$\mu$m thick. To improve the nonlinearity, this sensor is designed a rectangular silicon diaphragm with a center boss structure, and in order to improve the temperature characteristics of the sensor in a packaging process, the sensing element is mounted on the pyrex glass support. Some suggestions toward the design and fabrication of improved sensors have been presented. The zero pressure capacitance, Co of sensor is 26.57pF, and the change of capacitance, ${\Delta}$C is 1.55pF from 0Kgf/Cm$^{2}$ to 1Kgf/Cm$^{2}$ at room temperature. The nonlinearity of the sensor output with center boss diaphragm is 1.29%F.S., and thermal zero shift and thermal sensitivity shift is less than 1.43%F.S./$^{\circ}C$and 0.14% F.S./$^{\circ}C$, respectively.

  • PDF

용량형 지문인식센서를 위한 전하분할 방식 감지회로의 CMOS 구현 (A CMOS integrated circuit design of charge-sharing scheme for a capacitive fingerprint sensor)

  • 남진문;이문기
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.28-32
    • /
    • 2005
  • In this paper, a CMOS integrated detection circuit for capacitive type fingerprint sensor signal processing is described. We designed a detection circuit of charge-sharing sensing scheme. The proposed detection circuit increases the voltage difference between a ridge and valley. The test chip is composed of $160{\times}192$ array sensing cells (12 by $12.7{\;}mm^{2}$). The chip was fabricated on a 0.35 m standard CMOS process. Measured difference voltage between a ridge and valley was 0.95 V.

Patch-type large strain sensor using elastomeric composite filled with carbon nanofibers

  • Yasuoka, Tetsuo;Shimamura, Yoshinobu;Todoroki, Akira
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권2호
    • /
    • pp.146-151
    • /
    • 2013
  • Carbon nanofibers (CNFs) are electrically conductive. When CNFs are used as fillers in resin, this electrical conductivity can be yielded without adversely affecting the mechanical properties of the resin. When an elastomer is adopted as the resin, a conductive elastomer can then be produced. Due to its flexibility and conductive properties, a large strain sensor based on changes in resistivity may be produced, for strain sensing in flexible structures. In this study, a patch-type large strain sensor using resistivity change in a CNF/elastomer composite was proposed. The measurement limits of the sensor were investigated experimentally, and the limit was found to be 40%, which greatly exceeded the limits of conventional metal-foiled strain gages. Also, the proposed CNF/elastomer large strain sensor can be used to measure flexible materials, while conventional strain gages cannot be used to measure such strains.

고속/고정밀 위치 제어를 위한 이중 구동기를 이용한 회전 이송기구의 진동 제어 (Vibration Control of the Rotation Position Mechanism with Dual Actuator for High Precision Control)

  • 이용권;조원익;양현석;박영필
    • 한국정밀공학회지
    • /
    • 제18권4호
    • /
    • pp.203-208
    • /
    • 2001
  • In this paper, a novel dual-type positioning mechanism using a voice coil motor(VCM) and a piezoelectric actuator is proposed for optical disk drive or near-field recording type drive. The VCM is used for a coarse motion actuator and the piezoelectric actuator, "S" configuration deflection motion when voltage applied, is used for a fine motion actuator with self-sensing technique, which allows it to sense and actuate simultaneously in a closed loop frame work. When the VCM rotates and stops, a position feedback control algorithm is adopted to further control residu vibration. The performance of the control scheme is confirmed through simulations and experiments.

  • PDF

Quorum Sensing of Rhodobacter sphaeroides Negatively Regulates Cellular Poly-$\beta$-Hydroxybutyrate Content Under Aerobic Growth Conditions

  • Lee, Jeong-K.;Kho, Dhong-Hyo;Jang, Ji-Hee;Kim, Hye-Sun;Kim, Kun-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권3호
    • /
    • pp.477-481
    • /
    • 2003
  • The community escape response of Rhodobacter sphaeroides is exerted through the action of CerR and CerI, which code for a LuxR-type regulatory protein and acylhomoserine lactone synthase, respectively. Deletion of chromosomal DNA including cerR and cerI (mutant RI) or insertional interruption of cert (mutant AP3) resulted in two-fold increase in the cellular poly-${\beta}$-hydroxybutyrate (PHB) content In comparison with the wild-type under aerobic growth conditions. The PHB synthase (PhbC) activities of the cer mutants were doubled, and the enzyme expression was regulated at the level of phbC transcription. Thus, CerR, possibly in response to autoinducer (AI), appears to modulate the PHB content of aerobically grown cells by downregulating phbC transcription.

다공질 실리콘의 유기가스 검지 특성 (Sensing Properties of Porous Silicon Layer for Organic Vapors)

  • 김성진;이상훈;최복길
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.963-968
    • /
    • 2002
  • In this work, porous silicon (PS) layer is investigated as a sensing material to detect organic vapors such as ethanol (called alcohol), methanol, and acetone in low concentrations. To do this, PS sensors were fabricated. They have a membrane structure and comb-type electrodes were used to detect the change of electrical resistance effectively. PS layer on Si substrates was formed by anodization in HF solution of 25%. From fabricated sensors, current-voltage (Ⅰ-Ⅴ) curves were measured for gases evaporated from 0.1 to 0.5% organic solution concentrations at 36$\^{C}$. As the result, all curves showed rectifying behavior due to a diode structure between Si and the PS layer. The conductance of most sensors increased largely at high voltage of 5V, but the built-in potential on the measured Ⅰ-Ⅴ curve was lowered inversely by the adsorption effect of the organic vapors with high dipole moment.

구조물 안전진단을 위한 초음파능동형광섬유 센서의 개발 (Development of Ultrasonic Active Fiber Sensor for Structural Health Monitoring)

  • 임승현;이정률;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.747-752
    • /
    • 2008
  • Fiber-guided sensor system using a generator and a receiver can detect the amplitude of load or pressure. However, this type of sensor can show some difficulties in detecting the location of damages and pressure loadings. To overcome this weakness of this type, the ultrasonic active fiber sensor, which has an integrated ultrasonic generator and sensing part, was developed in this study. By using this sensor system, the location of mechanical loads can be exactly detected. Moreover, the ultrasonic active fiber sensor is more cost-effective than an ultrasonic fiber sensor using two piezoelectric transducers which are used as a generator and a receiver, respectively. Two applications of the ultrasonic active fiber sensor are demonstrated: cure monitoring of lead and measurement of liquid level. Present results showed that the active fiber sensor can be applied for various environmental sensing.

  • PDF

2쌍의 초음파센서를 이용한 측정면의 위치 측정 및 종류 분류 기법 (Localization and Classification of Target Surfaces using Two fairs of Ultrasonic Sensors)

  • 한영준;한헌수
    • 제어로봇시스템학회논문지
    • /
    • 제4권6호
    • /
    • pp.747-752
    • /
    • 1998
  • Ultrasonic sensors have been widely used to recognize the working environment for a mobile robot. However, their intrinsic problems, such as specular reflection, wide beam angle, and slow propagation velocity, require an excessive number of sensors to be integrated for achieving the sensing goal. This paper proposes a new measurement scheme which uses only two sets of ultrasonic sensors to determine the location and the type of a target surface. By measuring the time difference between the returned signals from the target surface, which are generated by two transmitters with 1 ㎳ difference, it classifies the type and determines the size of the target surface. Since the proposed sensor system uses only two sets of ultrasonic sensors to recognize and localize the target surface, it significantly simplifies the sensing system and reduces the signal processing time so that the working environment can be recognized in real time.

  • PDF

감응성막의 유기가스 응답특성 분석 (The Analysis of Organic Gas Response Characteristic for Polymer Coating Materials)

  • 김정명;권영수;유승엽;최용성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.417-419
    • /
    • 1995
  • Polymer-coated piezoelectric crystals were applied to analyze response characteristic of organic gases. AT-cut quartz crystal with 9 MHz resonant frequency can measure mass of 1 nanogram. Flow type gas-sensing system was used in this experiment. Flow type gas-sensing system has very simple apparatus and shows very fast frequency response for injection of organic gas. We have made parameter using relaxation ratio of frequency response for organic gas. Consequently, we found that the parameter had no relation with quantity of gas injection and dipping.

  • PDF

기둥을 이용한 다축 힘/모멘트 감지 방법에 관한 연구 (Sensing method of multi-component forces and moments using a column structure)

  • 신홍호;강대임;박연규;김종호;주진원;김옥현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.837-841
    • /
    • 2001
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor can solve the problem about low stiffness and high cost. The radius of the column was designed analytically and compared with finite element analysis. The coupling errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine in Korea Research Institute of Standards and Science(KRISS). The calibration showed that the multi-component force/moment sensor had coupling error less than 19.8 % between $F_x$ and $M_y$ components, and 9.0 % in case of other components.