• Title/Summary/Keyword: Sensing Volume

Search Result 224, Processing Time 0.025 seconds

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

CORRELATION ANALYSIS BETWEEN FOREST VOLUME, ETM+ BANDS, AND HEIGHT ESTIMATED FROM C-BAND SRTM PRODUCT

  • Kim, Jin-Woo;Kim, Jong-Hong;Lee, Jung-Bin;Heo, Joon
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.512-515
    • /
    • 2006
  • Forest stand height and volume are important indicators for management purpose as well as for the environmental analysis. Shuttle Radar Topography Mission (SRTM) is backscattered over forest canopy and DSM can be acquired from such scattering characteristic, while National Elevation Dataset (NED) provides bare earth elevation data. The difference between SRTM and NED is estimated as tree height, and it is correlated with forest parameters, it is correlated with forest parameters, including average DBH, Trees per acre, net BF per acre, and total Net MBF. Especially, among them, net Board Foot(BF) per acre is the index that well represents forest volume. The Project site was Douglas-fir dominating plantation area in the western Washington an the northern Oregon in the U.S. This study shows a relationship of high correlation between the forest parameters and the product from SRTM, NED, and ETM+. This research performs multi regression analysis and regression tree algorithm, and can get more improved relationship between several parameters.

  • PDF

Species Identification and Noise Cancellation Using Volume Backscattering Strength Difference of Multi-Frequency (다중 주파술의 체적산란강도 차이를 이용한 에코그램 내에서의 종 분리와 잡음 제거)

  • KANG Donhyug;SHIN Hyoung-Chul;KIM Suam;LEE Yoonho;HWANG Doojin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.541-548
    • /
    • 2003
  • Species identification in hydroacoustic survey is one of the key requirements to estimate biomass of organism and to understand the structure of zooplankton community. Feasibility of species identification using two frequencies (38 and 120 kHz) was investigated on the basis of mean volume backscattering strength difference (MVBS). Virtual echogram technique was applied to two frequencies data sets that obtained from surveys in the Antarctic Ocean and Yellow Sea. Virtual echogram method using MVBS revealed the possibility of species identification, which species identification relying on visual scrutiny of single frequency acoustic data resulted in significant errors in biomass estimation. Through noise cancellation using MVBS, much of the acoustic noise caused by acoustic instruments could be removed in new virtual echogram, and the biomass estimation and data quality was improved.

A Study on Obtaining Tree Data from Green Spaces in Parks Using Unmanned Aerial Vehicle Images: Focusing on Mureung Park in Chuncheon

  • Lee, Do-Hyung;Kil, Sung-Ho;Lee, Su-Been
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.4
    • /
    • pp.441-450
    • /
    • 2021
  • Background and objective: The purpose of study is to analyze the three-dimensional (3D) structure by creating a 3D model for green spaces in a park using unmanned aerial vehicle (UAV) images. Methods: After producing a digital surface model (DSM) and a digital terrain model (DTM) using UAV images taken in Mureung Park in Chuncheon-si, we generated a digital tree height model (DHM). In addition, we used the mean shift algorithm to test the classification accuracy, and obtain accurate tree height and volume measures through field survey. Results: Most of the tree species planted in Mureung Park were Pinus koraiensis, followed by Pinus densiflora, and Zelkova serrata, and most of the shrubs planted were Rhododendron yedoense, followed by Buxus microphylla, and Spiraea prunifolia. The average height of trees measured at the site was 7.8 m, and the average height estimated by the model was 7.5 m, showing a difference of about 0.3 m. As a result of the t-test, there was no significant difference between height values of the field survey data and the model. The estimated green coverage and volume of the study site using the UAV were 5,019 m2 and 14,897 m3, respectively, and the green coverage and volume measured through the field survey were 6,339 m2 and 17,167 m3. It was analyzed that the green coverage showed a difference of about 21% and the volume showed a difference of about 13%. Conclusion: The UAV equipped with RTK (Real-Time Kinematic) and GNSS (Global Navigation Satellite System) modules used in this study could collect information on tree height, green coverage, and volume with relatively high accuracy within a short period of time. This could serve as an alternative to overcome the limitations of time and cost in previous field surveys using remote sensing techniques.

Impacts of Surface Roughness Integration Using Remote Sensing Data: Concentration of Flood Flow Variation (원격탐사자료를 활용한 지표면 조도계수 통합의 영향: 홍수유출 변화를 중심으로)

  • Kang, Shin-Uk;Rieu, Seung-Yup;Lee, Kil-Ha;Hwang, Man-Ha
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.2 s.40
    • /
    • pp.33-42
    • /
    • 2007
  • A physical-based aggregation method was suggested to estimate surface roughness, which adequately represents the spatial heterogeneity of vegetation factors, from land cover property obtained from the remote sensing data. For the sensitivity analysis of surface roughness, the peak flow, peak time, and total volume were simulated by the NWS-PC. Effects of surface roughness estimated by three different integration methods (predominant, arithmetic mean, and aggregation approach) on the conceptual rainfall-runoff model parameters was analyzed. In the preliminary sensitivity test to surface roughness, the peak time had 10% variation and total volume had 2% variation. The peak time increased with surface roughness. A physical-based aggregation method was better than the existing method in the Soyanggang Dam basin for the results of STDEV, RMSE, NSE, and PME, but difference between them were small. The parameters related on the total baseflow were changed significantly with change of the surface roughness.

  • PDF

Density Estimation of an Euphauiid (Euphausia pacifica) in the Sound Scattering Layer of the East China Sea (동중국해 음향 산란층내의 euphausiid (Euphausia pacifica) 밀도 추정)

  • KANG Donhyug;HWANG Doojin;SOH Hoyoung;YOON Yangho;SUH Haelip;KIM Yongju;SHIN Hyunchul;IIDA Kohji
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.749-756
    • /
    • 2003
  • Hydroacoustic and open-closing zooplankton net survey were conducted to understand the characteristics of the sound scattering layer (SSL) and to estimate the density of an euphausiid (Euphausia pacifica) in the SSL, in the northwestern part of the East China Sea. The survey was carried out during July 6-9 2002 at 8 sampling stations for zooplankton. The virtual echogram technique was used to identify E. pacifica from all acoustic scatters. Mean volume backscattering strength difference $(MVBS_{120kHz-38kHz})$ and target strength equation for E. pacifica were derived from the Distorted-wave Born Approximation (DWBA) model. Although vertical migration of the SSL is similar to the general pattern, dispersion at night shows some differences. Estimated mean density using acoustic data ranged from $20.4-221.4\;mg/m^3$ over the whole depth, and $87.1-553.5\;mg/m^3$ in the SSL. The density using the zooplankton net ranged from $0.2-362.4\;mg/m^3$ and was not related to net deploying method. The results from the acoustic and net survey suggest that E. pacifica might be an important zooplankton community in the northwestern part of the East China Sea.

Advanced Abdominal MRI Techniques and Problem-Solving Strategies (복부 자기공명영상 고급 기법과 문제 해결 전략)

  • Yoonhee Lee;Sungjin Yoon;So Hyun Park;Marcel Dominik Nickel
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.345-362
    • /
    • 2024
  • MRI plays an important role in abdominal imaging because of its ability to detect and characterize focal lesions. However, MRI examinations have several challenges, such as comparatively long scan times and motion management through breath-holding maneuvers. Techniques for reducing scan time with acceptable image quality, such as parallel imaging, compressed sensing, and cutting-edge deep learning techniques, have been developed to enable problem-solving strategies. Additionally, free-breathing techniques for dynamic contrast-enhanced imaging, such as extra-dimensional-volumetric interpolated breath-hold examination, golden-angle radial sparse parallel, and liver acceleration volume acquisition Star, can help patients with severe dyspnea or those under sedation to undergo abdominal MRI. We aimed to present various advanced abdominal MRI techniques for reducing the scan time while maintaining image quality and free-breathing techniques for dynamic imaging and illustrate cases using the techniques mentioned above. A review of these advanced techniques can assist in the appropriate interpretation of sequences.

Evaluation of the Utilization Potential of High-Resolution Optical Satellite Images in Port Ship Management: A Case Study on Berth Utilization in Busan New Port (고해상도 광학 위성영상의 항만선박관리 활용 가능성 평가: 부산 신항의 선석 활용을 대상으로)

  • Hyunsoo Kim ;Soyeong Jang ;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_4
    • /
    • pp.1173-1183
    • /
    • 2023
  • Over the past 20 years, Korea's overall import and export cargo volume has increased at an average annual rate of approximately 5.3%. About 99% of the cargo is still being transported by sea. Due to recent increases in maritime cargo volume, congestion in maritime logistics has become challenging due to factors such as the COVID-19 pandemic and conflicts. Continuous monitoring of ports has become crucial. Various ground observation systems and Automatic Identification System (AIS) data have been utilized for monitoring ports and conducting numerous preliminary studies for the efficient operation of container terminals and cargo volume prediction. However, small and developing countries' ports face difficulties in monitoring due to environmental issues and aging infrastructure compared to large ports. Recently, with the increasing utility of artificial satellites, preliminary studies have been conducted using satellite imagery for continuous maritime cargo data collection and establishing ocean monitoring systems in vast and hard-to-reach areas. This study aims to visually detect ships docked at berths in the Busan New Port using high-resolution satellite imagery and quantitatively evaluate berth utilization rates. By utilizing high-resolution satellite imagery from Compact Advanced Satellite 500-1 (CAS500-1), Korea Multi-Purpose satellite-3 (KOMPSAT-3), PlanetScope, and Sentinel-2A, ships docked within the port berths were visually detected. The berth utilization rate was calculated using the total number of ships that could be docked at the berths. The results showed variations in berth utilization rates on June 2, 2022, with values of 0.67, 0.7, and 0.59, indicating fluctuations based on the time of satellite image capture. On June 3, 2022, the value remained at 0.7, signifying a consistent berth utilization rate despite changes in ship types. A higher berth utilization rate indicates active operations at the berth. This information can assist in basic planning for new ship operation schedules, as congested berths can lead to longer waiting times for ships in anchorages, potentially resulting in increased freight rates. The duration of operations at berths can vary from several hours to several days. The results of calculating changes in ships at berths based on differences in satellite image capture times, even with a time difference of 4 minutes and 49 seconds, demonstrated variations in ship presence. With short observation intervals and the utilization of high-resolution satellite imagery, continuous monitoring within ports can be achieved. Additionally, utilizing satellite imagery to monitor changes in ships at berths in minute increments could prove useful for small and developing country ports where harbor management is not well-established, offering valuable insights and solutions.

Fabrication of Methanol Sensors Using Conductive Polypyrrole Nanofibers with a Core-Shell Structure (코아-셀 구조를 가지는 전도성 폴리피롤 나노섬유를 이용한 메탄올 센서 제작)

  • Jun, Tae-Sun;Lee, Sungho;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.383-387
    • /
    • 2014
  • Electrically conductive polypyrrole-polyvinylpyrrolidone (PPy-PVP) nanofiber mats with a core-shell structure have been successfully fabricated by a two-step process: the formation of FeCl3-containing PVP nanofiber mat by electrospinning, and the vapor-phase polymerization (VPP) of pyrrole monomer on the mat in a sealed chamber at room temperature. Surface morphology and chemical composition of the PPy-PVP mat were characterized by SEM, EDX and FTIR analyses. The as-prepared nonwoven mat was composed of PPy-PVP nanofibers with an average diameter of 300 nm. The sheet conductivity of the nanofiber mat was measured to be approximately 0.01 S/cm by a four-point probe. We have also investigated gas-sensing properties of PPy-PVP nanofiber mat upon exposure to methanol vapor. The PPy-PVP nanofiber sensors were observed to have excellent methanol-sensing performance. The nanofiber-based core-shell nanostructure could give an opportunity to fabricate a highly sensitive and fast response sensor due to its high surfaceto-volume ratio.

Aerosol Optical Properties Retrieval and Separation of Asian Dust using AERONET Sun/Sky Radiometer Measurement at the Asian Dust Source Region (황사 발원지에서 선포토미터를 활용한 에어로졸의 광학적 특성 산출과 미세먼지속 황사구분)

  • Shin, Dongho;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.245-251
    • /
    • 2016
  • We present linear particle depolarization ratio at 440, 675, 870, and 1020 nm retrieved from measurements with an AERONET sun/sky radiometer at the source region of Asian dust, Dunhuang. The linear particle depolarization ratios are retrieved at the two receptor sites (Gosan and Osaka). The highest linear particle depolarization ratio of 0.34 at 1020 nm is retrieved from nearly pure Asian dust. The linear particle depolarization ratio decreased as the volume concentration of fine-mode particle increased. We can confirm that the ratio of Asian dust is changed by the value of the linear particle depolarization ratio retrieved by AERONET data.