• 제목/요약/키워드: Sensible heat ratio

검색결과 49건 처리시간 0.027초

다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석 (Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method)

  • 윤일철;이재헌
    • 대한기계학회논문집
    • /
    • 제19권12호
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

유기 플래쉬 사이클(OFC)의 열역학적 성능 특성 (Characteristics of Thermodynamic Performance of Organic Flash Cycle (OFC))

  • 김경훈;정영관;박상희
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.91-97
    • /
    • 2013
  • Recently a novel cycle named organic flash cycle (OFC) has been proposed which has improved potential for power generation from low-temperature heat sources. This study carries out thermodynamic performance analysis of OFC using various working fluids for recovery of low-grade heat sources in the form of sensible energy. Special attention is focused on the optimum flash temperature at which the exergy efficiency has the maximum value. Under the optimal conditions with respect to the flash temperature, the thermodynamic performances of important system variables including mass flow ratio, separation ratio, heat addition, specific volume flow rate at turbine exit, and exergy efficiency are thoroughly investigated. Results show that the exergy efficiency has a peak value with respect to the flash temperature and the optimum working fluid which shows the best exergy efficiency varies with the operating conditions.

이어도해양과학기지에서의 에디 공분산 방법을 이용한 플럭스 관측 (Tower-based Flux Measurement Using the Eddy Covariance Method at Ieodo Ocean Research Station)

  • 이희춘;이방용;김준;심재설
    • Ocean and Polar Research
    • /
    • 제26권2호
    • /
    • pp.145-154
    • /
    • 2004
  • Surface energy and $CO_2$ fluxes have been measured over an ocean at Ieodo Ocean Research Station of KORDI since May 2003. Eddy covariance technique, which is a direct flux measurement, is used to quantitatively understand the interaction between the ocean surface and the atmospheric boundary layer. Although fluxes were continuously measured during the period from May 2003 to February 2004, the quality control of these data yielded <20% of data retrieval. The atmospheric stability did not show any distinct dirunal patterns and remained near-neutral to stable from May to June but mostly unstable during fall and winter in 2003. Sensible heat flux showed a good correlation with the difference between the sea water temperature and the air temperature. The maximum fluxes of sensible heat and latent heat were $120Wm^{-2}$ and $350Wm^{-2}$ respectively, with an averaged Bowen ratio of 0.2. The ocean around the tower absorbed $CO_2$ from the atmosphere and the uptake rates showed seasonal variations. Based our preliminary results, the daytime $CO_2$ flux was steady with an average of $-0.1 mgCO_2m^{-2}s^{-1}$ in summer and increased in winter. The nighttime $CO_2$ uptake was greater and fluctuating, reaching up to $-0.1 mgCO_2m^{-2}s^{-1}$ but these data require further examination due to weak turbulent mixing at nighttime. The magnitude of $CO_2$ flux was positively correlated with the half hourly changes in horizontal mean wind speed. Due to the paucity of quality data, further data collection is needed for more detailed analyses and interpretation.

자갈식 축열조의 축열특성에 관한 연구 (A study on the Thermal Characteristics of a Thermal Storage Tank for using Gravels)

  • 박정원;박봉규;안상규
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.81-87
    • /
    • 1992
  • 본 연구의 목적은 건물의 냉난방에 이용되는 현열이용형 축열조의 축열 특성을 규명하는데 있었다. 실험에 사용된 축열재는 자갈이었으며 일정한 온도조건하에서 축열재 사이를 통과하는 유체의 유동속도와 자갈의 크기별로 실험을 하였다. 자갈의 크기와 유속을 변화시켜 축열량과 축열효율을 실험적으로 구한 결과 축열재의 충진율이 72.5%이고 유속이 0.14m/s일 때가 최단시간 내에 최대축열량에 도달하였으며, 축열효율도 가장 높았다.

  • PDF

도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석 (Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

열환경 완화를 통한 주택지내 쾌적성 확보에 관한 연구 (A Study on Thermal Comfortable Following the Thermal Environment Migration in Detached Housing Area)

  • 류지원;정응호;호야노 아키라;김대욱
    • 한국주거학회논문집
    • /
    • 제24권1호
    • /
    • pp.51-59
    • /
    • 2013
  • This study aims to improve the thermal comfort level of detached housing area by reducing the impact of thermal environment. The study focused on reducing surface temperature that is generated in buildings and adjacent spaces as a result of sensible heat load and presented a proposal on implementing planting method considering its outdoor condition and structure and composed materials. To perform the study, we utilized 3D-CAD to examine the outdoor condition and structure and composed materials that impact on surface temperature and conducted space design after reflecting climatic elements in simulations. The result is as follows. In reviewing temperature distribution of Heat Island Potential (HIP) of buildings and adjacent spaces, in case where green coverage ratio is increased, there was a $6^{\circ}C$ temperature difference and in regard to changes in the thermal environment in detached housing area, in case where rooftop planting, surface improvement, planting, and overall green coverage ratio is increased, there was a $10^{\circ}C$ temperature difference. In addition, there was difference in temperature in detached housing area following the changes in wind.

습공기선도 상에 20 종류의 상태 및 과정 값의 작도 (Drawing of Twenty Kinds of State and Process on Psychrometric Chart)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

제주연안에 강설을 수반하는 대륙성 한기단 확장 시 대기와 해양간의 열교환 특성 사례 연구 (Case Study on Characteristics of Heat Flux Exchange between Atmosphere and Ocean in the case of cP Expansion accompanying Snowfall over the Adjacent Sea of Jeju Island)

  • 김경보;방익찬;김길엽;김동호;이지미
    • 한국지구과학회지
    • /
    • 제26권5호
    • /
    • pp.395-403
    • /
    • 2005
  • 본 연구는 1993년부터 2003년 동안 겨울철 제주도 지방에 눈이 내린 경우를 대상으로 대기가 해양으로부터 얻은 열교환량을 계산하여 보웬비(현열속/잠열속)와 강설간의 관계를 분석한 것이다. 대상지역은 제주도 4개 관측지점인 제주, 서귀포, 성산포, 고산이다. 적설 예측의 신뢰도를 높일 수 있는 방법을 찾기 위하여 바람과 같은 기상의 영향이 가미된 보웬비와 적설과의 관계를 해기차와 적설과의 관계와 비교해 보았다. 그 결과 신적설 시, 지역별 최저 해기차는 제주시, 서귀포, 성산포, 고산에서 각각 10.9, 12.3, 11.5, $14.3^{\circ}C$였고, 그 이상의 해기차에서 신적설 확률은 각각 26, 29, 13, $23\%$인데 비해, 신적설시 지역별 최저 보웬비는 각각 0.59, 0.60, 0.65, 0.65였고, 그 이상의 보웬비에서 신적설 확률은 33, 70, 31, $58\%$로 나타나 보웬비가 해기차보다 높은 확률을 보였다. 보웬비에 의한 확률이 해기차에 의한 확률보다 높게 나타나는 이유는 해기차에 의해 형성된 강설의 조건에 바람에 의한 열교환이 강설의 조건을 강화시킨 것이 보웬비에 나타났기 때문으로 생각된다. 10년$(’93\~’02)$간 자료를 분석한 결과 각 지역별 신적설이 $10.0\~0.9cm$ 일 때 평균 보웬비는 $0.63\~0.67$이고 신적설이 $1.0\~4.9cm$ 일때 평균 보웬비는 0.72 이상으로 조사되어 강설시 적설량과 보웬비는 비례관계가 있음을 알 수 있었다.

E-GIS DB를 활용한 도시 고온화 영향인자 검토 (Examination of Factors Influencing Urban Higher Temperature using E-GIS DB)

  • 김금지;요코 카마타;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.44-49
    • /
    • 2009
  • In this study, we performed urrban climate simulation how both the factor of environmental land and artificial factors influence on the formation of urban temperature. With deducing quantitative data, this study could get more accurate results of the urban temperature using urban climate simulation system. In the case of natural land cover, it appeared that there are effects on the lowering temperature and the lower temperature rate appeared in the water land cover on the whole. This is considered as temperature in water land was low because of the characteristics of water land having evaporation latent heat was high and convective sensible heat was low. In case of building which has building coverage ratio, 5% with 10 floors and building coverage ratio, 15 % with 6 floors, it appears that the temperature in the water land is $33.6^{\circ}C$. In case of building coverage ratio 5%, temperature dropped when buildings has more than 4 stories. This is regarded as the size of building is bigger, the temperature dropped in relatively because of the fluctuation of the rate of solar heat from the land. At the present time, the urban temperature are higher because of various artificial factors in the city. With these results, this study supposed to be a basies of the future studies for considering both the composition of building coverate ratio and floor plan.

  • PDF

이어도 종합해양과학기지에서 관측된 난류 플럭스의 계절적 특성 (Seasonal Characteristics of Turbulent Fluxes Observed at leodo Ocean Research Station)

  • 오현미;하경자;심재설;현유경;윤경숙
    • 대기
    • /
    • 제17권4호
    • /
    • pp.421-433
    • /
    • 2007
  • We have investigated the seasonal characteristics of surface turbulent fluxes observed at Ieodo Ocean Research Station from 2005 to 2006. Both 10Hz and 30 minutes flux data are quality controled, and tilt correction is performed in 10Hz data before quality control. The turbulent fluxes of open sea shows clear seasonal variations, though diurnal variations are barely shown. The seasonal ratio of stable and unstable conditions are closely related to the temperature difference between sea surface and air. In stable and semi-stable condition, latent and sensible heat fluxes have very small values without any relationship with wind speed. Though friction velocity shows slightly increasing trend with wind speed, it has many outliers. In unstable condition, turbulent fluxes increased with wind speed. Especially, latent heat flux increased rapidly during DJF. The latent heat flux at high wind speeds is more scatter.