• Title/Summary/Keyword: Semiconductor Processing

Search Result 762, Processing Time 0.022 seconds

An efficient interconnection network topology in dual-link CC-NUMA systems (이중 연결 구조 CC-NUMA 시스템의 효율적인 상호 연결망 구성 기법)

  • Suh, Hyo-Joong
    • The KIPS Transactions:PartA
    • /
    • v.11A no.1
    • /
    • pp.49-56
    • /
    • 2004
  • The performance of the multiprocessor systems is limited by the several factors. The system performance is affected by the processor speed, memory delay, and interconnection network bandwidth/latency. By the evolution of semiconductor technology, off the shelf microprocessor speed breaks beyond GHz, and the processors can be scalable up to multiprocessor system by connecting through the interconnection networks. In this situation, the system performances are bound by the latencies and the bandwidth of the interconnection networks. SCI, Myrinet, and Gigabit Ethernet are widely adopted as a high-speed interconnection network links for the high performance cluster systems. Performance improvement of the interconnection network can be achieved by the bandwidth extension and the latency minimization. Speed up of the operation clock speed is a simple way to accomplish the bandwidth and latency betterment, while its physical distance makes the difficulties to attain the high frequency clock. Hence the system performance and scalability suffered from the interconnection network limitation. Duplicating the link of the interconnection network is one of the solutions to resolve the bottleneck of the scalable systems. Dual-ring SCI link structure is an example of the interconnection network improvement. In this paper, I propose a network topology and a transaction path algorism, which optimize the latency and the efficiency under the duplicated links. By the simulation results, the proposed structure shows 1.05 to 1.11 times better latency, and exhibits 1.42 to 2.1 times faster execution compared to the dual ring systems.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF