• 제목/요약/키워드: Semi-active Damper

검색결과 296건 처리시간 0.088초

Closed-loop active vibration control of a typical nose landing gear with torsional MR fluid based damper

  • Sateesh, B.;Maiti, Dipak K.
    • Structural Engineering and Mechanics
    • /
    • 제31권1호
    • /
    • pp.39-56
    • /
    • 2009
  • Vibration is an undesirable phenomenon in a dynamic system like lightly damped aerospace structures and active vibration control has gradually been employed to suppress vibration. The objective of the current investigation is to introduce an active torsional magneto-rheological (MR) fluid based damper for vibration control of a typical nose landing gear. They offer the adaptability of active control devices without requiring the associated large power sources. A torsional damper is designed and developed based on Bingham plastic shear flow model. The numerical analysis is carried out to estimate the damping coefficient and damping force. The designed damper is fabricated and an experimental setup is also established to characterize the damper and these results are compared with the analytical results. A typical FE model of Nose landing gear is developed to study the effectiveness of the damper. Open loop response analysis has been carried out and response levels are monitored at the piston tip of a nose landing gear for various loading conditions without damper and with MR-damper as semi-active device. The closed-loop full state feedback control scheme by the pole-placement technique is also applied to control the landing gear instability of an aircraft.

반능동 점성감쇠를 이용한 유체댐퍼 개발에 관한 연구 (A Study on the Development of a Hydraulic Damper using Semi-Active Viscous Damping)

  • 전종균;김현식
    • 한국산학기술학회논문지
    • /
    • 제1권2호
    • /
    • pp.15-20
    • /
    • 2000
  • 본 논문에서는 교량 밑 건축구조물, 각종 기계부품의 진동문제를 보완하기 위한 방법으로서 MR유체를 이용한 댐퍼를 연구하였다. MR 유체의 특성을 이용한 댐퍼를 모델링하여, 설계도면을 기초로 MR 댐퍼를 제작하였다. 만능재료 시험기를 이용하여 주파수와 전류 및 변위를 단계적으로 변화시켜가며 성능실험을 반복적으로 수행하였다. 실험을 통하여 주파수, 전류 및 변위에 따라 댐핑 효과가 다르게 나타남을 확인할 수 있었다.

  • PDF

상용 MR 댐퍼를 이용한 반능동형 착륙장치 낙하실험 (Drop Test Simulation of semi-active Landing Gear using Commercial Magneto-Rheological Damper)

  • 황재업;황재혁;배재성;임경호
    • 항공우주시스템공학회지
    • /
    • 제4권4호
    • /
    • pp.44-48
    • /
    • 2010
  • This paper is used the commercial magneto-rheological(MR) damper for landing gear. The damping characteristics of Commercial MR damper by changing the intensity of the magnetic field are investigated and the dynamic responses of the landing gear. it is set up tset equipment, the landing gear drop test system. The landing gear involved drop testing the gear. The landing gear is tested by implementing sky-hook control algorithm and its performance is evaluated comparing to the result.

  • PDF

반능동현가장치용 전자제어식 연속가변댐퍼의 모델링 및 동특성 해석 (Modeling and Dynamic Characteristics Analysis of a Continuously Variable Damper with Electro-Hydraulic Pressure Control Valve)

  • 도홍문;홍경태;홍금식
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.158-166
    • /
    • 2002
  • A mathematical model and dynamic characteristics ova continuously variable damper for semi-active suspen- sion systems are investigated. After analyzing the geometry of a typical continuously variable damper, mathematical models fur individual components including piston, orifices, spring, and valves are first derived and then the flow equations for extension and compression strokes are investigated. To verify the developed mathematical model, the dynamic response of the model are simulated using MATLAB/SIMULINK and are compared with experimental results. The proposed model can be used not only for mechanical components design but also for control system design.

대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용 (Real-time Hybrid Testing a Building Structure Equipped with Full-scale MR dampers and Application of Semi-active Control Algorithms)

  • 박은천;이성경;이헌재;문석준;정형조;민경원
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.465-474
    • /
    • 2008
  • 실시간 하이브리드 실험법(real-time hybrid testing method)은 구조물의 수치해석부와 실험부 부분구조를 운동방정식으로 통합하여 실시 간으로 동시에 계산과 실험을 수행하는 방법이다 본 연구는 실시간 하이브리드 실험법을 사용하여 수동 및 준능동 MR감쇠기가 설치된 건축구조물의 내진성능을 정량적으로 평가한다. 건물 모델은 실물 크기 5층 건물을 강제진동실험 결과를 통해 식별한 수치모델로 사용하였고, MR감쇠기는 실험적 부분구조르 UTM에 설치되었다. 본 연구에서 수행되는 실시간 하이브리드 실험은 사인파 및 지진파 가진을 통하여 얻은 결과와 전류에 따른 MR감쇠기의 제어력을 이용하여 얻은 Bouc-Wen모델을 사용하여 얻은 해석모델과 일치함으로 그 유효성을 입증하였다. 또한 예비연구로써 구조물의 응답을 최적으로 제어하기 위한 clipped-optimal 제어알고리즘과 modulated homogeneous friction 준능동 제어알고리즘을 MR감쇠기에 적용하였다. 각 전류별 Bouc-Wen모델을 곡선맞춤하여 각각의 Bouc-Wen모델 파라미터를 식별하였으며 그 결과를 준능동 제어알고리즘 수치해석에 적용하였다. 또한 실시간 하이브리드 실험법을 이용한 준능동 제어 실험결과와 해석결과를 비교하여 준능동 제어알고리즘의 성능을 평가함에 있어 실시간 하이브리드 실험이 합리적임을 보여준다.

영구자석을 이용한 밸브모드 MR 감쇠기 설계에 관한 연구 (A Study on the Design of Valve Mode MR Damper using Permanent Magnet)

  • 김정훈;오준호
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.69-76
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectiories.

  • PDF

MR fluid damper-based smart damping systems for long steel stay cable under wind load

  • Jung, Hyung-Jo;Jang, Ji-Eun;Choi, Kang-Min;Lee, Heon-Jae
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.697-710
    • /
    • 2008
  • Long steel stay cables, which are mainly used in cable-stayed bridges, are easy to vibrate because of their low inherent damping characteristics. A lot of methods for vibration reduction of stay cables have been developed, and several techniques of them have been implemented to real structures, though each has its limitations. Recently, it was reported that smart (i.e. semi-active) dampers can potentially achieve performance levels nearly the same as comparable active devices with few of the detractions. Some numerical and experimental studies on the application of smart damping systems employing an MR fluid damper, which is one of the most promising smart dampers, to a stay cable were carried out; however, most of the previous studies considered only one specific control algorithm in which they are interested. In this study, the performance verification of MR fluid damper-based smart damping systems for mitigating vibration of stay cables by considering the four commonly used semi-active control algorithms, such as the control algorithm based on Lyapunov stability theory, the maximum energy dissipation algorithm, the modulated homogeneous friction algorithm and the clipped-optimal control algorithm, is systematically carried out to find the most appropriate control strategy for the cable-damper system.

Semi-active eddy current pendulum tuned mass damper with variable frequency and damping

  • Wang, Liangkun;Shi, Weixing;Zhou, Ying;Zhang, Quanwu
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.65-80
    • /
    • 2020
  • In order to protect a structure over its full life cycle, a novel tuned mass damper (TMD), the so-called semi-active eddy current pendulum tuned mass damper (SAEC-PTMD), which can retune its frequency and damping ratio in real-time, is proposed in this study. The structural instantaneous frequency is identified through a Hilbert-Huang transformation (HHT), and the SAEC-PTMD pendulum is adjusted through an HHT-based control algorithm. The eddy current damping parameters are discussed, and the relationship between effective damping coefficients and air gaps is fitted through a polynomial function. The semi-active eddy current damping can be adjusted in real-time by adjusting the air gap based on the linear-quadratic-Gaussian (LQG)-based control algorithm. To verify the vibration control effect of the SAEC-PTMD, an idealized linear primary structure equipped with an SAEC-PTMD excited by harmonic excitations and near-fault pulse-like earthquake excitations is proposed as one of the two case studies. Under strong earthquakes, structures may go into the nonlinear state, while the Bouc-Wen model has a wild application in simulating the hysteretic characteristic. Therefore, in the other case study, a nonlinear primary structure based on the Bouc-Wen model is proposed. An optimal passive TMD is used for comparison and the detuning effect, which results from the cumulative damage to primary structures, is considered. The maximum and root-mean-square (RMS) values of structural acceleration and displacement time history response, structural acceleration, and displacement response spectra are used as evaluation indices. Power analyses for one earthquake excitation are presented as an example to further study the energy dissipation effect of an SAECPTMD. The results indicate that an SAEC-PTMD performs better than an optimized passive TMD, both before and after damage occurs to the primary structure.

Vibration isolation with smart fluid dampers: a benchmarking study

  • Batterbee, D.C.;Sims, N.D.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.235-256
    • /
    • 2005
  • The non-linear behaviour of electrorheological (ER) and magnetorheological (MR) dampers makes it difficult to design effective control strategies, and as a consequence a wide range of control systems have been proposed in the literature. These previous studies have not always compared the performance to equivalent passive systems, alternative control designs, or idealised active systems. As a result it is often impossible to compare the performance of different smart damper control strategies. This article provides some insight into the relative performance of two MR damper control strategies: on/off control and feedback linearisation. The performance of both strategies is benchmarked against ideal passive, semi-active and fully active damping. The study relies upon a previously developed model of an MR damper, which in this work is validated experimentally under closed-loop conditions with a broadband mechanical excitation. Two vibration isolation case studies are investigated: a single-degree-of-freedom mass-isolator, and a two-degree-of-freedom system that represents a vehicle suspension system. In both cases, a variety of broadband mechanical excitations are used and the results analysed in the frequency domain. It is shown that although on/off control is more straightforward to implement, its performance is worse than the feedback linearisation strategy, and can be extremely sensitive to the excitation conditions.