• Title/Summary/Keyword: Semi-Direct Structural Analysis

Search Result 18, Processing Time 0.02 seconds

Structural Design and Analysis of Barge for Canal-Coastal Shipping (운하-연안 연계용 바아지의 구조 설계 및 해석)

  • Kim, Kyung-Su;Son, Choong-Yul;Kim, Sung-Joon
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.26-34
    • /
    • 1999
  • Two types of barge, container and tanker vessels, are designed with specific dimensions for canal-coastal shipping in Kyung-In canal and Yellow Sea region. The principal dimensions of barges are determined by considering the environment of Kyung-In canal and Yellow Sea. The selection of structure type and structure type and strength confirmation is conducted by the technical rules of Korean Register of Shipping. For the structural analysis of designed barges, the semi-direct stuctural analysis is carried out with using MSC NASTRAN software. Applying identical dimensions to both vessels, the standardization of structural design and analysis procedure are introduced.

  • PDF

Direct analysis of steel frames with asymmetrical semi-rigid joints

  • Chan, Jake L.Y.;Lo, S.H.
    • Steel and Composite Structures
    • /
    • v.31 no.1
    • /
    • pp.99-112
    • /
    • 2019
  • Semi-rigid joints have been widely studied in literature in recent decades because they affect greatly the structural response of frames. In literature, the behavior of semi-rigid joints is commonly assumed to be identical under positive and negative moments which are obviously incorrect in many cases where joint details such as bolt arrangement or placement of haunch are vertically asymmetrical. This paper evaluates two common types of steel frames with asymmetrical beam-to-column joints by Direct Analysis allowing for plasticity. A refined design method of steel frames using a proposed simple forth order curved-quartic element with an integrated joint model allowing for asymmetrical geometric joint properties is presented. Furthermore, the ultimate behavior of six types of asymmetrical end-plate connections under positive and negative moment is examined by the Finite Element Method (FEM). The FEM results are further applied to the proposed design method with the curved-quartic element for Direct Analysis of two types of steel frames under dominant gravity or wind load. The ultimate frame behavior under the two different scenarios are examined with respect to their failure modes and considerably different structural performances of the frames were observed when compared with the identical frames designed with the traditional method where symmetrical joints characteristics were assumed. The finding of this research contributes to the design of steel frames as their asymmetrical beam-to-column joints lead to different frame behavior when under positive and negative moment and this aspect should be incorporated in the design and analysis of steel frames. This consideration of asymmetrical joint behavior is recommended to be highlighted in future design codes.

The discrete element method simulation and experimental study of determining the mode I stress-intensity factor

  • Shemirani, Alireza Bagher;Haeri, Hadi;Sarfarazi, Vahab;Akbarpour, Abbas;Babanouri, Nima
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.379-386
    • /
    • 2018
  • The present study addresses the direct and indirect methods of determining the mode-I fracture toughness of concrete using experimental tests and particle flow code. The direct method used is compaction tensile test and the indirect methods are notched Brazilian disc test, semi-circular bend specimen test, and hollow center cracked disc. The experiments were carried out to determine which indirect method yields the fracture toughness closer to the one obtained by the direct method. In the numerical analysis, the PFC model was first calibrated with respect to the data obtained from the Brazilian laboratory test. The crack paths observed in the simulated tests were in reasonable accordance with experimental results. The discrete element simulations demonstrated that the macro fractures in the models are caused by microscopic tensile breakages on large numbers of bonded particles. The mode-I fracture toughness in the direct tensile test was smaller than the indirect testing results. The fracture toughness obtained from the SCB test was closer to the direct test results. Hence, the semi-circular bend test is recommended as a proper experiment for determination of mode-I fracture toughness of concrete in the absence of direct tests.

A Study on the Estimation of Underground Parameters by Coupling of Finite and Boundary Elements (유한요소 - 경계요소 조합에 의한 지반매개변수 추정에 관한 연구)

  • 김문겸;장정범;오금호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.28-34
    • /
    • 1995
  • Behavior of underground structural systems is usually complicated because of various unknown parameters. In order to construct those structural systems safely and economically, exact identification of the system parameters and accurate analysis of the system behaviors are essentially required. In this study, a forward analysis program, which is able to eliminate numerical errors due to far field boundary effect, is developed by coupling finite and boundary elements. In this coupled analysis, boundary elements are used in the semi-infinite domain where stress variation is small, and finite elements in the stress concentration region where material nonlinearity should be considered. Then, a back analysis program which can identify the system parameters is developed using the direct method to be combined with the forward analysis program. The elastic modulus and initial stress, which are most important in the description of the behavior of underground structures, are taken as the system parameters. A simple example is examined 0 show that the method can be used effectively.

  • PDF

Nonlinear semi-active/passive retrofit design evaluation using incremental dynamic analysis

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Roland, Thomas;Macrae, Gregory A.;Zhou, Cong
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.109-120
    • /
    • 2022
  • Older or damaged structures can require significant retrofit to ensure they perform well in subsequent earthquakes. Supplemental damping devices are used to achieve this goal, but increase base shear forces, foundation demand, and cost. Displacement reduction without increasing base shear is possible using novel semi-active and recently-created passive devices, which offer energy dissipation in selected quadrants of the force-displacement response. Combining these devices with large, strictly passive energy dissipation devices can offer greater, yet customized response reductions. Supplemental damping to reduce response without increasing base shear enables a net-zero base shear approach. This study evaluates this concept using two incremental dynamic analyses (IDAs) to show displacement reductions up to 40% without increasing base shear, more than would be achieved for either device alone, significantly reducing the risk of response exceeding the unaltered structural case. IDA results lead to direct calculation of reductions in risk and annualized economic cost for adding these devices using this net-zero concept, thus quantifying the trade-off. The overall device assessment and risk analysis method presented provides a generalizable proof-of-concept approach, and provides a framework for assessing the impact and economic cost-benefit of using modern supplemental energy dissipation devices.

Semi-active friction dampers for seismic control of structures

  • Kori, Jagadish G.;Jangid, R.S.
    • Smart Structures and Systems
    • /
    • v.4 no.4
    • /
    • pp.493-515
    • /
    • 2008
  • Semi-active control systems have attracted a great deal of attention in recent years because these systems can operate on battery power alone, proving advantageous during seismic events when the main power source of the structure may likely fail. The behavior of semi-active devices is often highly non-linear and requires suitable and efficient control algorithm. This paper presents the comparative study and performance of variable semi-active friction dampers by using recently proposed predictive control law with direct output feedback. In this control law, the variable slip force of semi-active variable friction damper is kept slightly lower than the critical friction force, which allows the damper to remain in the slip state during an earthquake, resulting in improved energy dissipation capability. This control algorithm is able to produce a continuous and smooth slip forces for a variable friction damper. The numerical examples include a structure controlled with multiple variable semi-active friction dampers and with multiple passive friction dampers. A parameter, gain multiplier defined as the ratio of damper force to critical damper control force, is investigated under four different real earthquake ground motions, which plays an important role in the present control algorithm of the damper. The numerically evaluated optimum parametric value is considered for the analysis of the structure with dampers. The numerical results of the variable friction dampers show better performance over the passive dampers in reducing the seismic response of structures.

A study on the inner flow fields characteristics of the Semi-active muffler (반능동형 머플러 내부의 유동장특성에 관한 연구)

  • Park Kyoung-Suk;Heo Hyung-Seok;Park Se-Jong;Son Sung-Man;Kim Dong-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.125-131
    • /
    • 2006
  • Recently air pollution has become an important issue. So, as tile number of vehicles increases, the noise pollution has become one of the most serious social issues nowadays. It is a muffler, which is one of the vehicle components. that has the hugest impact on the noise from the vehicle. And it also has a direct influence on the engine performance. So lately the research is proceeding on tile semi-active muffler which can control the back pressure variably by setting up the exhaust variable valve in the baffle to improve its internal structure. The inner parts of muffler which consist of a baffle, pipes and etc. appear to have the complicated turbulence phenomena by the pulsational wave of an unsteady state in the engine and by the structural characteristics of the inner parts. To analyze these phenomena, it is required to have an analysis of its constant quantity and quality. Therefore this study is to analyze with PIV measurement which can analyze the time and space variables, not with the point measurement method like former multi-point anemometer. It is to suggest proper design variables which need to make internal structure of the muffler improve though comparison between the passive type muffler and the semi-active muffler by fabricating a muffler which can be visualized.

Pseudo plastic zone analysis of steel frame structures comprising non-compact sections

  • Avery, P.;Mahendran, M.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.4
    • /
    • pp.371-392
    • /
    • 2000
  • Application of "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A concentrated plasticity method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in this paper. The pseudo plastic zone method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established by comparison with a comprehensive range of analytical benchmark frame solutions. The pseudo plastic zone method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.

Comparison of various methods to obtain structural vibration for vibro-acoustic noise (구조 방사 소음의 해석을 위한 구조물의 진동 획득 방법의 비교)

  • Wang Se-Myung;Shin Min-Cheol;Koo Kun-Mo;Kim Dae-Sung;Bae Won-Ki;Kyong Yong-Soo;Kim Jung-Seon;Kook Jung-Hwan;Thuy Tran ho Vihn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.607-611
    • /
    • 2006
  • There are several methods to obtain structural vibration for analysis of vibro-acoustic noise. First of all, vibration data can be obtained through the structural analysis using finite element method. Although this method has no need to experiment, the analysis result is unreliable when the structure and the vibration source is complex to model exactly. The second method is to measure vibration using a number of sensors. The analyzed vibro-acoustic noise with directly measured data is setting morereliable when the number of data acquisition points is getting larger. However, it requires large amount of time and effort to measure all vibration data on every node especially when the size of vibrating structure is large. The Modal Expansion Method(MEM), which uses mode information and measurement data, has been introduced to compensate their limits. With a relatively small number of measurement data, the reliable structural vibration for vibro-acoustic noise can be obtained using this semi-analysis method. Although MEM gives reliable result, it is restricted by the number of modes and measurement points. In this paper, structural analysis, direct vibration measurement method and MEM are compared using the simple aluminum box model. Furthermore, the washing machine case is also provided as a comparative example. The Laser Doppler Vibrometer(LDV) was used instead of contact type accelerometer to get vibration data.

  • PDF

Mode III fracture analysis of piezoelectric materials by Trefftz BEM

  • Qin, Qing-Hua
    • Structural Engineering and Mechanics
    • /
    • v.20 no.2
    • /
    • pp.225-239
    • /
    • 2005
  • Applications of the Trefftz boundary element method (BEM) to anti-plane electroelastic problems are presented in this paper. Both direct and indirect methods with domain decomposition are discussed in details. Each crack is treated as semi-infinite thin slit defined in a subregion, for which a particular solution of the anti-plane problem, satisfying exactly the crack-face condition, is derived. The stress intensity factors defined at each crack tip can be directly computed from the coefficients of the particular solution. The performance of the proposed formulation is assessed by two examples and comparison is made with results obtained by other approaches. The Trefftz boundary element approach is demonstrated to be suitable for the analysis of the anti-plane problem of piezoelectric materials.