• Title/Summary/Keyword: Self-correction

Search Result 237, Processing Time 0.034 seconds

Implementation of Telemetry System using Scatternet in Bluetooth Technology (블루투스의 스캐터넷과 임베디드 시스템을 이용한 텔레메트리 시스템의 구현)

  • 김종현;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.941-944
    • /
    • 2003
  • This paper implement Telemetry System which is used Bluetooth. This System propose system which can detect a total amount of gas, electricity or water without a motorman, at home. BlueTooth is a close range wireless communication technology which uses a wireless frequency 2.4GHz and has a high trust and self - error correction technology according to a low power consumption quality and a high-speed frequency hopping. This makes get a high trust concerning a data transmission than an existing modem. In addition, though wireless modem is restricted by a minimal of a wireless terminal, it will be possible to coincide with the function of the portable with the low power consumption quality by using Bluetooth. And as the system on a chip of module progresses, the possibility of the snail size is present. And, Motorman who use mobility of embedded system can detect detect a total amount of gas, electricity or water outdoor. Embedded system use ARM processor that is low power processor. So it ran use long time efficiently.

  • PDF

The Effects of Body Type Perception on the Quality of Life and Disease Morbidity

  • Lee, Myeong-Jin;Lee, Jung-Min;Choi, Bong-Joon
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1056-1064
    • /
    • 2018
  • Purpose. This study reported on body type perception of people aged ${\geq}19years$, regardless of gender, and on its association with disease morbidity and the quality of life and aimed to observe the effects of stress on body weight perception, disease morbidity, and the quality of life. Methods. The data from 218,899 persons aged ${\geq}19years$ who were respondents to the 2010 Community Health Survey were finally analyzed. A designated program was used to perform complex sample analysis; chi-square test was carried out to determine body type perception by the general characteristics and disease status and analyze health-related behavior and weight control behavior by body type perception, and multiple logistic regression was used to observe the effects of body type perception on mental health and the quality of life. Results. 34.9% of all the respondents misperceived their body type and females were more likely to misperceive their body type. The older they were, the more poorly they perceived their body type; those perceiving their body type poorly were significantly more susceptible to both hypertension and diabetes. When correction was made in relation to gender, age, and so on, those perceiving their body type excessively were more susceptible to hypertension (1.43[1.367-1.050]) and diabetes morbidity (1.36[1.294-1.428]). Body type perception affected the quality of life: the respondents perceiving their body type poorly (0.91[0.884-0.940]) or excessively (0.75[0.720-0.770]) showed lower quality of life than those perceiving their body type correctly. Conclusions. Distorted body type perception affected disease morbidity and the quality of life: the respondents excessively perceiving their body type were significantly more susceptible to both hypertension and diabetes and those perceiving their body type excessively or poorly showed lower quality of life than those perceiving it correctly. It is therefore necessary to make multilateral efforts to cultivate correct body type perception.

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.520-523
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHZ bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with bluetooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

The Etiology and Treatment of the Softened Phallus after the Radial Forearm Osteocutaneous Free Flap Phalloplasty

  • Kim, Seok-Kwun;Kim, Tae-Heon;Yang, Jin-Il;Kim, Myung-Hoon;Kim, Min-Soo;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.390-396
    • /
    • 2012
  • Background The radial forearm osteocutaneous free flap is considered to be the standard technique for penile construction. One year after their operation, most patients experience a softened phallus, so that they suffer from difficulties in sexual intercourse. In this report, we present our experience with phalloplasty by radial forearm osteocutaneous free flap, as well as an evaluation of the etiology and treatment of the softened phallus. Methods Between March 2005 and February 2010, 58 patients underwent phalloplasty by radial forearm osteocutaneous free flap. Most of their neophallus had been softened subjectively and among them, 12 patients who wanted correction were investigated. We performed repetitive fat injection, artificial dermis grafting, silicone rod insertion, and rib bone with cartilaginous tip graft. Physical examination, plain radiograph, computed tomography, bone scintigraphy, and satisfaction scores were investigated. Results Most of the participants' penises have been softened after phalloplasty, and the skin elasticity had been also decreased. On plain radiograph, the distal end of the bone was self-rounded; however, the bone shape of the neophallus had no significant interval changes or resorption. Computed tomography showed equivocal density of cortical bone. On bone scintigraphy, the bone metabolism was active at 3 months postoperatively, and remained active 9 years postoperatively. Conclusions The use of a rib bone with cartilaginous tip graft could be an option for improvement of the softened phallus. Silicon rod insertion is also worth considering for rigidity of the softened phallus. Decreased rigidity due to soft tissue atrophy could be alleviated with repeated fat injection and artificial dermis grafting.

The parental origin correlates with the karyotype of human embryos developing from tripronuclear zygotes

  • Joergensen, Mette Warming;Labouriau, Rodrigo;Hindkjaer, Johnny;Stougaard, Magnus;Kolevraa, Steen;Bolund, Lars;Agerholm, Inge Errebo;Sunde, Lone
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.42 no.1
    • /
    • pp.14-21
    • /
    • 2015
  • Objective: It has previously been suggested that embryos developing from intracytoplasmic sperm-injected (ICSI) zygotes with three pronuclei (3PN) are endowed with a mechanism for self-correction of triploidy to diploidy. 3PN are also observed in zygotes after conventional in vitro fertilization (IVF). The parental origin, however, differs between the two fertilization methods. Whereas the vast majority of 3PN IVF zygotes are of dispermic origin and thus more likely to have two centrioles, the 3PN ICSI zygotes are digynic in origin and therefore, more likely to have one centriole. In the present study, we examine whether the parental origin of 3PN embryos correlates with the karyotype. Methods: The karyotype of each nucleus was estimated using four sequential fluorescence in situ hybridizations-each with two probes-resulting in quantitative information of 8 different chromosomes. The karyotypes were then compared and correlated to the parental origin. Results: 3PN ICSI embryos displayed a significantly larger and more coordinated reduction from the assumed initial 3 sets of chromosomes than 3PN IVF embryos. Conclusion: The differences in the parental origin-and hence the number of centrioles-between the 3PN IVF and the 3PN ICSI zygotes are likely to be the cause of the differences in karyotypes.

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHz bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with blutooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

Anisotropy of Magnetic Susceptibility (AMS) of Anorthositic Rocks in the Hadong-Sanchong Area (하동-산청지역에 분포하는 회장암질암에 대한 대자율 비등방성 연구)

  • Kim, Seong Uk;Choe, Eun Gyeong;Kim, In Su
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.169-178
    • /
    • 1999
  • Low-field anisotropy of magnetic susceptibility (AMS) was measured with 247 samples from 17 sites of Pre-Cambrian anorthositic rocks in the Hadong-Sanchong area, southwestern part of the Ryongnam Block. Tectonic stress-direction is defined by the minimum susceptibility (k3) direction, and flow-direction by the maximum susceptibility (k1) direction. Five sites rendered self-consistent NW-SE site-mean tectonic stress-direction. Even though a general fold test for every site was not possible due to the homoclinal nature of the bedding attitudes, a site with various bedding attitudes shows far better clustering of the k3-direction before the bedding-tilt correction. The in-situ NW-SE tectonic stress-direction is consistent over the study area and compatible with petrographic foliation observed in metamorphic rocks in and arround the study area, suggesting a regional compressive force acted after the emplacement of the anorthositic rocks. On the other hand, flow-directions obtained from six sites varies from site to site. Strong-field IRM experiments show predominance of titanomagnetites over a small amount of hematite in some samples.

  • PDF

Influence of modeling agents on the surface properties of an esthetic nano-hybrid composite

  • Kutuk, Zeynep Bilge;Erden, Ecem;Aksahin, Damla Lara;Durak, Zeynep Elif;Dulda, Alp Can
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.13.1-13.10
    • /
    • 2020
  • Objective: The aim of this study was to evaluate the influence of different modeling agents on the surface microhardness (Vickers hardness number; VHN), roughness (Ra), and color change (ΔE) of a nano-hybrid composite with or without exposure to discoloration by coffee. Materials and Methods: Sixty-four cylinder-shaped nano-hybrid composite specimens were prepared using a Teflon mold. The specimens' surfaces were prepared according to the following groups: group 1, no modeling agent; group 2, Modeling Liquid; group 3, a universal adhesive (G-Premio Bond); and group 4, the first step of a 2-step self-adhesive system (OptiBond XTR). Specimens were randomly allocated into 2 groups (n = 8) according to the storage medium (distilled water or coffee). VHN, Ra, and ΔE were measured at 24 hours, 1 week, and 6 weeks. The Kruskal-Wallis test followed by the Bonferroni correction for pairwise comparisons was used for statistical analysis (α = 0.05). Results: Storage time did not influence the VHN of the nano-hybrid composite in any group (p > 0.05). OptiBond XTR Primer application affected the VHN negatively in all investigated storage medium and time conditions (p < 0.05). Modeling Liquid application yielded improved Ra values for the specimens stored in coffee at each time point (p < 0.05). Modeling Liquid application was associated with the lowest ΔE values in all investigated storage medium and time conditions (p < 0.05). Conclusion: Different types of modeling agents could affect the surface properties and discoloration of nano-hybrid composites.

Coefficient of Thermal Expansion Measurement of Concrete using Electrical Resistance Strain Gauge (전기저항식 변형률 게이지를 이용한 콘크리트의 열팽창계수 측정법)

  • Nam, Jeong-Hee;An, Deok-Soon;Kim, Yeon-Bok
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.25-32
    • /
    • 2013
  • PURPOSES : The purpose of this study is to provide the method of how to measure the coefficient of thermal expansion of concrete using temperature compensation principle of electrical resistance strain gauge. METHODS : The gauge factor compensation method and thermal output(temperature-induced apparent strain) correction method of self-temperature compensation gauge were investigated. From the literature review, coefficient of thermal expansion measurement method based on the thermal output differential comparison between reference material(invar) and unknown material(concrete) was suggested. RESULTS : Thermal output is caused by two reasons; first the electrical resistivity of the grid conductor is changed by temperature variation and the second contribution is due to the differential thermal expansion between gauge and the test material. Invar was selected as a reference material and it's coefficient of thermal expansion was measured as $2.12{\times}10^{-6}m/m/^{\circ}C$. by KS M ISO 11359-2. The reliability of the suggested measurement method was evaluated by the thermal output measurement of invar and mild steel. Finally coefficient of thermal expansion of concrete material for pavement was successfully measured as $15.45{\times}10^{-6}m/m/^{\circ}C$. CONCLUSIONS : The coefficient of thermal expansion measurement method using thermal output differential between invar and unknown concrete material was evaluated by theoretical and experimental aspects. Based on the test results, the proposed method is considered to be reasonable to apply for coefficient of thermal expansion measurement.

Isotopic Fissile Assay of Spent Fuel in a Lead Slowing-Down Spectrometer System

  • Lee, Yongdeok;Jeon, Juyoung;Park, Changje
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.549-555
    • /
    • 2017
  • A lead slowing-down spectrometer (LSDS) system is under development to analyze isotopic fissile content that is applicable to spent fuel and recycled material. The source neutron mechanism for efficient and effective generation was also determined. The source neutron interacts with a lead medium and produces continuous neutron energy, and this energy generates dominant fission at each fissile, below the unresolved resonance region. From the relationship between the induced fissile fission and the fast fission neutron detection, a mathematical assay model for an isotopic fissile material was set up. The assay model can be expanded for all fissile materials. The correction factor for self-shielding was defined in the fuel assay area. The corrected fission signature provides well-defined fission properties with an increase in the fissile content. The assay procedure was also established. The assay energy range is very important to take into account the prominent fission structure of each fissile material. Fission detection occurred according to the change of the Pu239 weight percent (wt%), but the content of U235 and Pu241 was fixed at 1 wt%. The assay result was obtained with 2~3% uncertainty for Pu239, depending on the amount of Pu239 in the fuel. The results show that LSDS is a very powerful technique to assay the isotopic fissile content in spent fuel and recycled materials for the reuse of fissile materials. Additionally, a LSDS is applicable during the optimum design of spent fuel storage facilities and their management. The isotopic fissile content assay will increase the transparency and credibility of spent fuel storage.