• Title/Summary/Keyword: Selective relay

Search Result 43, Processing Time 0.029 seconds

Integrated Protection Method for DC Railway Systems (통합형 직류철도 보호계전 방식)

  • Kang, Sang-Hee;Choi, Chang-Young;Lee, Won-Seok;Jung, Ho-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.285-292
    • /
    • 2011
  • DC traction power system is operated ungrounded so that minimize the stray current. Because the stray current is still present, a rail potential is increased. The ground faults in the DC railway systems are usually detected by a potential relay(64P). Moreover, if the rail potential goes high in the ordinary operating state because of the traction load, the potential relay would be maloperated. A presented protective relaying algorithm that can identify exactly the faulted region and can distinguish a ground fault from the potential rising of the rail is presented in this paper. This paper presents simulation technique that is very similar to the real operation situation using PSCAD/EMTDC.

Outage Analysis of OFDM-Based Dual-hop Multi-Relay Systems with Best Relay Selection (최선 릴레이 선택을 적용한 OFDM 기반 이중-홉 다중 릴레이 시스템의 아웃티지 성능 분석)

  • Park, Jae-Cheol;Wang, Jin-Soo;Lee, Ji-Hye;Kim, Yun-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.5C
    • /
    • pp.487-494
    • /
    • 2010
  • This paper presents an OFDM-based dual-hop multi-relay system with best relay selection maximizing the mutual information. For the system either with decode-and-forward (DF) relays or with amplify-and-forward (AF) relays, we derive a lower-bound on the outage probability and the diversity order achievable in frequency selective fading channels and provide the outage capacity from simulation. Performance evaluation shows that both DF and AF provide the same diversity order as in the lower-bound but DF of which the outage probability is much closer to the lower-bound provides a better outage capacity than AF. It is also observed that the SNR gain of DF over AF gets larger as either the number of resolvable multipaths or the number of relay candidates increases, which makes DF relaying more favorable to the OFDM-based multi-relay system.

Semi-Analytical Averaged Error Rate Evaluation for DSF-Relay MC-CDMA systems over Multipath Rayleigh Fading Channels (다중경로 레일리 페이딩 채널에 대한 DSF 릴레이 MC-CDMA 시스템의 평균 오류율 의사 분석 기법)

  • Ko, Kyun-Byoung
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • In this paper, a semi-analytical approach is proposed for DSF(Decode and Selective Forward)-Relay MC-CDMA(MultiCarrier-Code Division Multiple Access) systems over multipath Rayleigh fading channels. Considering BER(bit error rate) performance and complexity, the MMSE-C(Minimum Mean squared Error-per subCarrier) is used as the combining method for MC-CDMA systems. At first, the analytical method based on error-events at relay nodes for DSF-Relay schemes is utilized in order to derive the averaged BER. Then, the averaged BER is expressed as the form considering possible all error-events. Also, proposed semi-analytical expressions have been verified by comparing with simulation results. Finally, it is verified that the derived analytical expressions can be a frame work to cover different multipath Rayleigh fading channel conditions and to measure the upper performance for DSF-Relay MC-CDMA systems.

An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System (도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가)

  • Jung, Hosung;Kim, Joouk;Shin, Seongkuen;Kim, Hyungchul;An, Taepung;Yun, Junseok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Study of Set-Operation Based Analytical Approach for OAF Relay Systems over Rayleigh Fading channels (레일리 페이딩 채널에서의 OAF 릴레이 시스템에 대한 집합 연산 기반의 분석 기법에 관한 연구)

  • Ko, Kyun-Byoung;Seo, Jeong-Tae;Kim, Hag-Wone
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.198-204
    • /
    • 2011
  • In this letter, another analytical approach for the opportunistic amplify-and-forward (OAF) relay systems is proposed over Rayleigh fading channels. Based on set-operation at the selected relay node, its selection probability as the best relay is derived and then, the probability density function (PDF) of the received instantaneous signal-to-noise ratio (SNR) is expressed as a more tractable form in which the number of summations and the length of each summation are specified. Then, the average error rate, outage probability, and average channel capacity are obtained as approximated closed-forms. Simulation results are finally presented to validate that the proposed analytical expressions can be a unified frame work covering all Rayleigh fading channel conditions. Furthermore, it is confirmed that OAF schemes can outperform the other non-selective schemes on the average error rate, outage probability, and average channel capacity.

A Relay and Transmission Mode Selection Scheme to Enhance the Bit Error Rate Performance in Relay Systems (중계기 시스템에서 비트 오류율 성능 향상을 위한 중계기 선택 및 전송 모드 결정 방법)

  • Seo, Jong-Pil;Lee, Myung-Hoon;Lee, Yoon-Ju;Kwon, Dong-Seung;Chung, Jae-Hak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12A
    • /
    • pp.941-949
    • /
    • 2011
  • In a cooperative communication system with a source node and multiple relays equipping single antenna and a destination node equipping multiple antennas, the selective cooperative spatial multiplexing scheme can obtain spatial multiplexing gain and additional selection diversity gain. But it can degrade a bit error rate performance because some received symbols forwarded from particular relays may be lost by attenuation due to path-loss. We propose a relay and transmission mode selection scheme which selects minimum number of multiple relays having the channel capacity larger than a given data rate and transmission mode which switches spatial multiplexing and spatial diversity mode in cooperation phase to enhance the bit error rate performance. The proposed scheme achieves 1.5~2dB gain at the low SNR range compared with the conventional scheme by obtaining additional spatial diversity gain.

A Cooperative Transmission Scheme Based on Alamouti Coding for Cognitive Radio Networks Over Frequency Selective Fading Channels (주파수 선택적 페이딩 채널에서 안치 무선 통신을 위한 Alamouti 코딩 기반 협력 전송 기법)

  • Kang, Seung-Goo;Kim, Jun-Hwan;Baek, Jee-Hyeon;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.403-411
    • /
    • 2011
  • This paper addresses a cooperative transmission scheme based on Alamouti coding for cognitive radio networks over frequency selective fading channels. In the proposed scheme, the Alamouti coded form at the destination node is constructed through a simple combination of symbols at the source node, instead of the time-reversal operation and the conjugate operation at the relay nodes used in the conventional scheme. Numerical results show that the proposed scheme achieves a higher order cooperative diversity than that of the conventional scheme.

Improved Ground differential relaying algorithm for the protection of a line-to-line fault of transformer (변압기의 선간 단락사고 보호를 위한 지락비율차동 계전 알고리즘의 성능향상 방법)

  • Kang, Hae-Gweon;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.760-761
    • /
    • 2011
  • Ground differential relay is used to provide fast, sensitive, and selective protection for the wye connected and grounded electrical power equipment such as generators, power transformers, and grounding transformers. The ground differential protection only protects the ground faults within the protection zone, so that it can't protect the line-to-line fault. This paper proposes the algorithm to provide the protection for the line-to-line fault through the ground differential protection. The proposed algorithm detects the line-to-line fault of transformer using the comparison between the positive and the negative current, when the ground differential relay dose not operate. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various case studies.

  • PDF

The Advanced Protection Coordination Scheme using Phase Angle of Zero-Sequence Current in Ungrounded System (비접지 계통에서 영상전류 위상을 이용한 개선된 보호협조 방안)

  • Choi, Young-Jun;Lim, Hee-Taek;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. The protection coordination method using SGR(Selective Ground Relay) and OVGR(Overvoltage Ground Relay) is generally used in ungrounded system. But this method only detects fault line and it has the possibility of malfunction. This paper proposed to advanced protection coordination method in ungrounded system. The method just using zero-sequence current can detect fault line, fault phase, fault section at terminal device. The general protection method is used to back up protection. In the case study, the proposed method has been testified in demo system by Matlab/Simulink simulations.

Design of IEC 61850 Logical Nodes for Modeling Protective Elements of Selective-Breaking Integrated Protective Relay for DC Traction Power Supply System (DC 급전계통 선택차단형 통합보호계전기 보호요소 IEC 61850 Logical Node 설계)

  • Yun, Jun-Seok;Kim, In-Woong;Kim, Jin-Ho;An, Tae-Pung;Jung, Ho-Sung;Jung, Tae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.491-496
    • /
    • 2012
  • There are several protective relays used to protect DC traction power supply system for DC railway. These relays, however, are made by different manufactures and they have different ways for their operations. Therefore, there are difficulties for cooperation between the devices or the devices and an upper system. In order to increase interoperability and stability of the system composed of devices made by different manufactures, IEC 61850 international standards are applied to design logical nodes for modeling protective elements used in protective relays.