• 제목/요약/키워드: Seismic wave

검색결과 773건 처리시간 0.026초

Probabilistic analysis of tunnel collapse: Bayesian method for detecting change points

  • Zhou, Binghua;Xue, Yiguo;Li, Shucai;Qiu, Daohong;Tao, Yufan;Zhang, Kai;Zhang, Xueliang;Xia, Teng
    • Geomechanics and Engineering
    • /
    • 제22권4호
    • /
    • pp.291-303
    • /
    • 2020
  • The deformation of the rock surrounding a tunnel manifests due to the stress redistribution within the surrounding rock. By observing the deformation of the surrounding rock, we can not only determine the stability of the surrounding rock and supporting structure but also predict the future state of the surrounding rock. In this paper, we used grey system theory to analyse the factors that affect the deformation of the rock surrounding a tunnel. The results show that the 5 main influencing factors are longitudinal wave velocity, tunnel burial depth, groundwater development, surrounding rock support type and construction management level. Furthermore, we used seismic prospecting data, preliminary survey data and excavated section monitoring data to establish a neural network learning model to predict the total amount of deformation of the surrounding rock during tunnel collapse. Subsequently, the probability of a change in deformation in each predicted section was obtained by using a Bayesian method for detecting change points. Finally, through an analysis of the distribution of the change probability and a comparison with the actual situation, we deduced the survey mark at which collapse would most likely occur. Surface collapse suddenly occurred when the tunnel was excavated to this predicted distance. This work further proved that the Bayesian method can accurately detect change points for risk evaluation, enhancing the accuracy of tunnel collapse forecasting. This research provides a reference and a guide for future research on the probability analysis of tunnel collapse.

적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출 (Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera)

  • 권대주;정나라;김재열
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가 (Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests)

  • 유민택;권선용
    • 한국지반공학회논문집
    • /
    • 제34권7호
    • /
    • pp.51-58
    • /
    • 2018
  • 본 연구에서는 하중 조건에 따른 지반-말뚝 상호작용 시스템의 거동 차이를 분석하기 위해 일련의 원심모형 실험을 수행하였다. 정적 하중 조건의 경우, 말뚝 직경의 50% 수준까지 변위제어를 통해 하중을 재하하였으며, 지진 하중 조건의 경우 0.1g~0.4g 수준으로 1Hz 정현파를 가진하였다. 실험 결과로부터 얻은 정적 및 동적 p-y 곡선을 API p-y 곡선과 비교한 결과, API p-y 곡선과 정적 하중조건에서의 실험 p-y 곡선은 최대 지반반력 값이 20% 이내의 오차를 보인 반면, 동적 하중 조건에서의 실험 p-y 곡선과는 최대 지반반력 값이 5배 이상 차이가 발생하였다. 이는 등가정적 해석에서 기존 API p-y 곡선을 적용할 경우 비선형 영역에서 지반 반력을 크게 과소평가하며 보수적 설계를 야기할 수 있음을 의미한다.

발파실험과 내진해석을 통한 Anchor의 동적 저항성에 관한 연구 (Dynamic Resistance of Anchor using Blasting Test and Numerical analysis for Earthquake)

  • 최경집;조국환
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.500-511
    • /
    • 2017
  • 최근 경주지진이 일어나게 되면서 지진의 진동에 의한 구조물의 안정성에 대한 관심이 증가하고 있다. 하지만 국내 앵커분야의 경우 설계하중에 대한 안정성만 고려하고 있을 뿐 진동에 대한 안정성에 대한 연구는 미미한 실정이다. 마찰형 앵커의 경우 시공 중 발생하는 발파진동 등으로 인하여 앵커의 저항능력을 상실한 경우가 종종 보고되고 있다. 이에 반하여 지압형 앵커의 경우 구조적으로 마찰형 앵커에 비하여 진동저항능력이 우수할 것으로 판단되나 이러한 특성에 대한 연구는 거의 진행되지 않았다. 본 연구에서는 새롭게 개발한 지압형 앵커의 발파진동과 지진에 대한 안정성을 검증하기 위하여 현장시험을 수행하였으며 수치해석을 통하여 내진안정성을 검증하였다. 그 결과 현장시험의 경우에는 마찰형 앵커보다 발파진동에 대한 저항성능이 우수하였으며, 수치해석을 이용한 내진해석의 경우 또한 마찰형 앵커에 비하여 저항성능이 우수한 것으로 분석되었다.

Soil-structure interaction vs Site effect for seismic design of tall buildings on soft soil

  • Fatahi, Behzad;Tabatabaiefar, S. Hamid Reza;Samali, Bijan
    • Geomechanics and Engineering
    • /
    • 제6권3호
    • /
    • pp.293-320
    • /
    • 2014
  • In this study, in order to evaluate adequacy of considering local site effect, excluding soil-structure interaction (SSI) effects in inelastic dynamic analysis and design of mid-rise moment resisting building frames, three structural models including 5, 10, and 15 storey buildings are simulated in conjunction with two soil types with the shear wave velocities less than 600 m/s, representing soil classes $D_e$ and $E_e$ according to the classification of AS1170.4-2007 (Earthquake actions in Australia) having 30 m bedrock depth. Structural sections of the selected frames were designed according to AS3600:2009 (Australian Standard for Concrete Structures) after undertaking inelastic dynamic analysis under the influence of four different earthquake ground motions. Then the above mentioned frames were analysed under three different boundary conditions: (i) fixed base under direct influence of earthquake records; (ii) fixed base considering local site effect modifying the earthquake record only; and (iii) flexible-base (considering full soil-structure interaction). The results of the analyses in terms of base shears and structural drifts for the above mentioned boundary conditions are compared and discussed. It is concluded that the conventional inelastic design procedure by only including the local site effect excluding SSI cannot adequately guarantee the structural safety for mid-rise moment resisting buildings higher than 5 storeys resting on soft soil deposits.

초음파의 매질 투과성을 이용한 시추공 케이싱 배면의 암상 및 절리구조 조사 연구 (Use of Ultrasonic beam transmissivity for investigating the structural features in plastic pipe cased borehole)

  • 김중열;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.751-758
    • /
    • 2002
  • Boreholes that are drilled in soft or unconsolidated materials such as gravels and coals are prone to collapse. To maintain the hole, some kinds of casing pipes are needed. If thereby a plastic pipe e.g. PVC is used for the casing, Televiewer tool is still capable of detecting structural features such as fractures in the borehole wall behind the pipe, whereas other borehole-imaging logging devices such as BIPS (Borehole Image Processing System) and FMS(Formation Micro Scanner) won't provide any information about that. Televiewer's primary component is a piezoelectric transducer centered in the hole. It acts as both a transmitter and receiver, and sends an ultrasonic beam. That is reflected, in the same manner as the seismic wave propagation, from the both sides(inner and outer surfaces) of the casing pipe, transmits through the pipe and then reflected from the borehole wall. With an appropriate choice of time-windowing, it is possible to capture the returning signals from both the borehole wall and the outer side of casing pipe as well. A suite of laboratory tests were performed on various physical models composed of plastic pipes with different diameters. Although the amplitudes of returning signals were reduced to about half the usual value due to the transmission loss, the dynamic range of Televiewer tool was sufficient to observe the structural features behind the casing pipe. Besides, several representative case studies at various research areas in our country are presented. The results demonstrate the usefulness of the transmissivity of Televiewer acoustic km, which will assist in further structural interpretation.

  • PDF

해상풍력발전기 자켓 지지구조물의 최적설계 및 신뢰성해석 (Design Optimization and Reliability Analysis of Jacket Support Structure for 5-MW Offshore Wind Turbine)

  • 이지현;김수영;김명현;신성철;이연승
    • 한국해양공학회지
    • /
    • 제28권3호
    • /
    • pp.218-226
    • /
    • 2014
  • Since the support structure of an offshore wind turbine has to withstand severe environmental loads such as wind, wave, and seismic loads during its entire service life, the need for a robust and reliable design increases, along with the need for a cost effective design. In addition, a robust and reliable support structure contributes to the high availability of a wind turbine and low maintenance costs. From this point of view, this paper presents a design process that includes design optimization and reliability analysis. First, the jacket structure of the NREL 5-MW offshore wind turbine is optimized to minimize the weight and stresses, while satisfying the design requirements. Second, the reliability of the optimum design is evaluated and compared with that of the initial design. Although the present study results in a new optimum shape for a jacket support structure with reduced weight and increased reliability, the authors suggest that the optimum design has to be accompanied by a reliability analysis during the design process, as well as reliability based design optimization if needed.

구조물의 비선형 동적 해석을 위한 무한요소의 개발 (Development of an Infinite Element for Non-linear Dynamic Analysis of Structures)

  • 권민호;한길웅
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.1053-1058
    • /
    • 2010
  • 지반과 구조물의 상호작용을 해석하는 한 방법으로 지반을 무한의 영역으로 가정하여 이를 무한요소로 모델링한 후 구조물과 연동하여 해석하는 기법이 사용되었으나 하지만 기존의 동적 무한요소는 대부분 시간영역이 아닌 주파수 영역에서 정식화되었고 중첩의 원리가 적용되어 구조물이나 지반의 비선형 거동을 해석에 포함하기 어렵다. 본 연구에서는 시간영역에서 정식화가 가능하고 비선형 거동해석도 가능한 무한 요소를 개발하였다. 개발된 무한요소를 다량의 유한요소를 사용한 결과와 비교하여 정확도를 검증하였고, 비선형 지반모델을 적용하여 비선형해석이 가능함을 확인하였다. 따라서 개발된 무한요소를 지반-구조물 상호작용에 적용할 수 있으며, 이를 바탕으로 구조물내진 설계에도 활용할 수 있을 것으로 판단된다.

CONCEPTUAL DESIGN OF THE SODIUM-COOLED FAST REACTOR KALIMER-600

  • Hahn, Do-Hee;Kim, Yeong-Il;Lee, Chan-Bock;Kim, Seong-O;Lee, Jae-Han;Lee, Yong-Bum;Kim, Byung-Ho;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • 제39권3호
    • /
    • pp.193-206
    • /
    • 2007
  • The Korea Atomic Energy Research Institute has developed an advanced fast reactor concept, KALIMER-600, which satisfies the Generation IV reactor design goals of sustainability, economics, safety, and proliferation resistance. The concept enables an efficient utilization of uranium resources and a reduction of the radioactive waste. The core design has been developed with a strong emphasis on proliferation resistance by adopting a single enrichment fuel without blanket assemblies. In addition, a passive residual heat removal system, shortened intermediate heat-transport system piping and seismic isolation have been realized in the reactor system design as enhancements to its safety and economics. The inherent safety characteristics of the KALIMER-600 design have been confirmed by a safety analysis of its bounding events. Research on important thermal-hydraulic phenomena and sensing technologies were performed to support the design study. The integrity of the reactor head against creep fatigue was confirmed using a CFD method, and a model for density-wave instability in a helical-coiled steam generator was developed. Gas entrainment on an agitating pool surface was investigated and an experimental correlation on a critical entrainment condition was obtained. An experimental study on sodium-water reactions was also performed to validate the developed SELPSTA code, which predicts the data accurately. An acoustic leak detection method utilizing a neural network and signal processing units were developed and applied successfully for the detection of a signal up to a noise level of -20 dB. Waveguide sensor visualization technology is being developed to inspect the reactor internals and fuel subassemblies. These research and developmental efforts contribute significantly to enhance the safety, economics, and efficiency of the KALIMER-600 design concept.

H-TMD with hybrid control method for vibration control of long span cable-stayed bridge

  • Han, Bing;Yan, Wu Tong;Cu, Viet Hung;Zhu, Li;Xie, Hui Bing
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.349-358
    • /
    • 2019
  • Long span cable-stayed bridges are extremely vulnerable to dynamic excitations such as which caused by traffic load, wind and earthquake. Studies on cable-stayed bridge vibration control have been keenly interested by researchers and engineers in design new bridges and assessing in-service bridges. In this paper, a novel Hybrid-Tuned Mass Damper (H-TMD) is proposed and a hybrid control model named Mixed Logic Dynamic (MLD) is employed to build the bridge-H-TMD system to mitigate the vibrations. Firstly, the fundamental theory and modeling process of MLD model is introduced. After that, a new state switching design of the H-TMD and state space equations for different states are proposed to control the bridge vibrations. As the state switching designation presented, the H-TMDs can applied active force to bridge only if the structural responses are beyond the limited thresholds, otherwise, the vibrations can be reduced by passive components of dampers without active control forces provided. A new MLD model including both passive and active control states is built based on the MLD model theory and the state switching design of H-TMD. Then, the case study is presented to demonstrate the proposed methodology. In the case study, the control scheme with H-TMDs is applied for a long span cable-stayed bridge, and the MLD model is established and simulated with earthquake excitation. The simulation results reveal that the suggested method has a well damping effect and the established system can be switched between different control states as design excellently. Finally, the energy consumptions of H-TMD schemes are compared with that of Active Tuned Mass Damper (ATMD) schemes under variable seismic wave excitations. The compared results show that the proposed H-TMD can save energy than ATMD.