• Title/Summary/Keyword: Seismic responses

Search Result 961, Processing Time 0.025 seconds

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • v.32 no.5
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

Seismic Response Evaluation of NPP Structures Considering Different Numerical Models and Frequency Contents of Earthquakes (다양한 수치해석 모델과 지진 주파수 성분을 고려한 원전구조물의 지진 응답 평가)

  • Thusa, Bidhek;Nguyen, Duy-Duan;Park, Hyosang;Lee, Tae-Hyung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.63-72
    • /
    • 2020
  • The purpose of this study is to investigate the effects of the application of various numerical models and frequency contents of earthquakes on the performances of the reactor containment building (RCB) in a nuclear power plant (NPP) equipped with an advanced power reactor 1400. Two kinds of numerical models are developed to perform time-history analyses: a lumped-mass stick model (LMSM) and a full three-dimensional finite element model (3D FEM). The LMSM is constructed in SAP2000 using conventional beam elements with concentrated masses, whereas the 3D FEM is built in ANSYS using solid elements. Two groups of ground motions considering low- and high-frequency contents are applied in time-history analyses. The low-frequency motions are created by matching their response spectra with the Nuclear Regulatory Commission 1.60 design spectrum, whereas the high-frequency motions are artificially generated with a high-frequency range from 10Hz to 100Hz. Seismic responses are measured in terms of floor response spectra (FRS) at the various elevations of the RCB. The numerical results show that the FRS of the structure under low-frequency motions for two numerical models are highly matched. However, under high-frequency motions, the FRS obtained by the LMSM at a high natural frequency range are significantly different from those of the 3D FEM, and the largest difference is found at the lower elevation of the RCB. By assuming that the 3D FEM approximates responses of the structure accurately, it can be concluded that the LMSM produces a moderate discrepancy at the high-frequency range of the FRS of the RCB.

A Feasibility Study of AMT Application to Tidal Flat Sedimentary Layer (갯벌 지역의 하부퇴적층에 대한 AMT 탐사의 적용 가능성 평가)

  • Kwon, Byung-Doo;Lee, Choon-Ki;Park, Gye-Soon;Choi, Su-Young;Yoo, Hee-Young;Choi, Jong-Keun;Eom, Joo-Young
    • Journal of the Korean earth science society
    • /
    • v.28 no.1
    • /
    • pp.64-74
    • /
    • 2007
  • The marine seismic prospecting using a research vessel in the shallow sea near the coastal area has certain limits according to the water depth and survey environment. Also, for the electrical resistivity survey at seashore area, one may need a specially designed high-voltage source to penetrate the very conductive surface layer. Therefore, we have conducted a feasibility study on the application of magnetotelluric method (MT), a passive geophysical method, on investigating of shallow marine environment geology. Our study involves both theoretical modeling and field survey at the tidal flat area which represent the very shallow marine environment. We have applied the audio-frequency magnetotelluric (AMT) method to the intertidal deposits of Gunhung Bay, west coast of Korea, and analysed the field data both qualitatively and quantitatively to investigate the morphology and sedimentary stratigraphy of the tidal flat. The inversion of AMT data well reveals the upper sedimentary layer of Holocene intertidal sediments having a range of 13-20 m thickness and the erosional patterns at the unconformable contact boundary. However, the AMT inversion results tend to overestimate the depth of basement (30-50 m) when compared with the seismic section (27-33 m). Since MT responses are not significantly sensitive to the resistivity of middle layer or the depth of basement, the AMT inversion result for basement may have to be adjusted using the comparison with other geophysical information like seismic section or logging data if possible. But, the AMT method can be an effective alternative choice for investigating the seashore area to get important basic informations such as the depositional environment of the tidal flat, sea-water intrusion and the basement structure near the sea shore.

Correlation of Experimental ana Analytical Inelastic Responses of 1:12 Scale Irregular High-Rise RC Buildings (1:12축소 비정형 고층 RC 건물의 비선형거동에 대한 실험과 해석의 상관성)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.95-104
    • /
    • 2007
  • Three types of high-rise RC building structures having irregularity in the lower two stories were selected as prototypes and were performed nonlinear static analysis by using OpenSees to verify the analysis technique and to investigate the seismic capacity of those buildings. The first one has a symmetrical moment resisting frame (Model 1), the second has an infilled shear wall in the central frame (Model 2), and the third has an infilled shear wall only in one of exterior frames (Model 3). Fiber model, which consists of concrete and reinforcing bar represented from stress-strain relationship, is adapted used for simulate the nonlinearity of members, and MVLEM(Multi vertical linear element model) is used for simulate the behavior of wall. The analytical results are simulate the behavior of piloti stories well, for example, the stiffness and yield farce of piloti stories, the up-lift of wall and the variation of lateral stiffness of column due to the variation of axial forces. Overstrength of Model 2 and Model 3 are about 2 times larger than that of Model 1. The reason of the high oversttrength and ductility of Model 2 and Model 3 is that the conservative design of Model 2 and Model 3, whose beam and column sections are the same as those of Model 1. The ductilities of Model 1 and Model 3 are slightly larger than that of Model 1 and Model 3. Model 1 and Model 3 reached mechanism condition, whereas Model 2 failed to the shear failure of shear wall and the large axial forces in columns due to large overturning moment.

Real-time Hybrid Testing a Building Structure Equipped with Full-scale MR dampers and Application of Semi-active Control Algorithms (대형 MR감쇠기가 설치된 건축구조물의 실시간 하이브리드 실험 및 준능동 알고리즘 적용)

  • Park, Eun-Churn;Lee, Sung-Kyung;Lee, Heon-Jae;Moon, Suk-Jun;Jung, Hyung-Jo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.465-474
    • /
    • 2008
  • The real-time hybrid testing method(RT-HYTEM) is a structural testing technique in which the numerical integration of the equation of motion for a numerical substructure and the physical testing for an experimental substructure are performed simultaneously in real-time. This study presents the quantitative evaluation of the seismic performance of a building structure installed with an passive and semi-active MR damper by using RT-HYTEM. The building model that was identified from the force-vibration testing results of a real-scaled 5-story building is used as the numerical substructure, and an MR damper corresponding to an experimental substructure is physically tested by using the universal testing machine(UTM). The RT-HYTEM implemented in this study is validated because the real-time hybrid testing results obtained by application of sinusoidal and earthquake excitations and the corresponding analytical results obtained by using the Bouc-Wen model as the control force of the MR damper respect to input currents were in good agreement. Also for preliminary study, some semi-active control algorithms were applied to the MR damper in order to control the structural responses optimally. Comparing between the test results of semi-active control using RT-HYTEM and numerical analysis results show that the RT-HYTEM is more resonable than numerical analysis to evaluate the performance of semi-active control algorithms.

Characteristics of the Point-source Spectral Model for Odaesan Earthquake (M=4.8, '07. 1. 20) (오대산지진(M=4.8, '07. 1. 20)의 점지진원 스펙트럼 모델 특성)

  • Yun, Kwan-Hee;Park, Dong-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.241-251
    • /
    • 2007
  • The observed spectra from Odaesan earthquake were fitted to a point-source spectral model to evaluate the source spectrum and spatial features of the modelling error. The source spectrum was calculated by removing from the observed spectra the path and site dependent responses (Yun, 2007) that were previously revealed through an inversion process applied to a large accumulated spectral dataset. The stress drop parameter of one-corner Brune's ${\omega}^2$ source model fitted to the estimated source spectrum was well predicted by the scaling relation between magnitude and stress drop developed by Yun et al. (2006). In particular, the estimated spectrum was quite comparable to the two-corner source model that was empirically developed for recent moderate earthquakes occurring around the Korean Peninsula, which indicates that Odaesan earthquake is one of typical moderate earthquakes representative of Korean Peninsula. Other features of the observed spectra from Odaesan earthquake were also evaluated based on the commonly treated random error between the observed data and the estimated point-source spectral model. Radiation pattern of the error according to azimuth angle was found to be similar to the theoretical estimate. It was also observed that the spatial distribution of the errors was correlated with the geological map and the $Q_0$ map which are indicatives of seismic boundaries.

Extracting Foundation Input Motion Considering Soil-Subterranean Level Kinematic Interaction (지하층-지반 운동학적 상호작용을 고려한 기초저면의 설계지반운동 산정)

  • Sadiq, Shamsher;Yoon, Jinam;Kim, Juhyong;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.31-37
    • /
    • 2018
  • Most of tall building systems are composed of above-ground structure and underground structure used for parking and stores. The underground structure may have a pronounced influence on tall building response, but its influence is still not well understood. In a widely referred report on seismic design of tall buildings, it is recommended to model the underground structure ignoring the surrounding ground and to impose input ground motion calculated considering the underground structure-soil kinematic interaction between at its base. In this study, dynamic analyses are performed on 1B and 5B basements. The motions at the base are calculated to free field responses. The motions are further compared to two procedures outlined in the report to account for the kinematic interaction. It is shown that one of the procedure fits well for the 1B model, whereas both procedures provide poor fit with 5B model analysis result.

Design of Communication Board for Communication Network of Nuclear Safety Class Control Equipment (원자력 안전등급 제어기기의 통신망을 위한 통신보드 설계)

  • Lee, Dongil;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.185-191
    • /
    • 2015
  • This paper suggest the safety class communication board in order to design the safety network of the nuclear safety class controller. The reactor protection system use the digitized networks because from analog system to digital system. The communication board shall be provided to pass the required performance and test of the safety class in the digital network used in the nuclear safety class. Communication protocol is composed of physical layer(PHY), data link layer(MAC: Medium Access Control), the application layer in the OSI 7 layer only. The data link layer data package for the cyber security has changed. CRC32 were used for data quality and the using one way communication, not requests and not responses for receiving data, does not affect the nuclear safety system. It has been designed in accordance with requirements, design, verification and procedure for the approving the nuclear safety class. For hardware verification such as electromagnetic test, aging test, inspection, burn-in test, seismic test and environmental test in was performed. FPGA firmware to verify compliance with the life-cycle of IEEE 1074 was performed by the component testing and integration testing.

Automated Finite Element Analyses for Structural Integrated Systems (통합 구조 시스템의 유한요소해석 자동화)

  • Chongyul Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • An automated dynamic structural analysis module stands as a crucial element within a structural integrated mitigation system. This module must deliver prompt real-time responses to enable timely actions, such as evacuation or warnings, in response to the severity posed by the structural system. The finite element method, a widely adopted approximate structural analysis approach globally, owes its popularity in part to its user-friendly nature. However, the computational efficiency and accuracy of results depend on the user-provided finite element mesh, with the number of elements and their quality playing pivotal roles. This paper introduces a computationally efficient adaptive mesh generation scheme that optimally combines the h-method of node movement and the r-method of element division for mesh refinement. Adaptive mesh generation schemes automatically create finite element meshes, and in this case, representative strain values for a given mesh are employed for error estimates. When applied to dynamic problems analyzed in the time domain, meshes need to be modified at each time step, considering a few hundred or thousand steps. The algorithm's specifics are demonstrated through a standard cantilever beam example subjected to a concentrated load at the free end. Additionally, a portal frame example showcases the generation of various robust meshes. These examples illustrate the adaptive algorithm's capability to produce robust meshes, ensuring reasonable accuracy and efficient computing time. Moreover, the study highlights the potential for the scheme's effective application in complex structural dynamic problems, such as those subjected to seismic or erratic wind loads. It also emphasizes its suitability for general nonlinear analysis problems, establishing the versatility and reliability of the proposed adaptive mesh generation scheme.

Acceleration of computation speed for elastic wave simulation using a Graphic Processing Unit (그래픽 프로세서를 이용한 탄성파 수치모사의 계산속도 향상)

  • Nakata, Norimitsu;Tsuji, Takeshi;Matsuoka, Toshifumi
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.98-104
    • /
    • 2011
  • Numerical simulation in exploration geophysics provides important insights into subsurface wave propagation phenomena. Although elastic wave simulations take longer to compute than acoustic simulations, an elastic simulator can construct more realistic wavefields including shear components. Therefore, it is suitable for exploration of the responses of elastic bodies. To overcome the long duration of the calculations, we use a Graphic Processing Unit (GPU) to accelerate the elastic wave simulation. Because a GPU has many processors and a wide memory bandwidth, we can use it in a parallelised computing architecture. The GPU board used in this study is an NVIDIA Tesla C1060, which has 240 processors and a 102 GB/s memory bandwidth. Despite the availability of a parallel computing architecture (CUDA), developed by NVIDIA, we must optimise the usage of the different types of memory on the GPU device, and the sequence of calculations, to obtain a significant speedup of the computation. In this study, we simulate two- (2D) and threedimensional (3D) elastic wave propagation using the Finite-Difference Time-Domain (FDTD) method on GPUs. In the wave propagation simulation, we adopt the staggered-grid method, which is one of the conventional FD schemes, since this method can achieve sufficient accuracy for use in numerical modelling in geophysics. Our simulator optimises the usage of memory on the GPU device to reduce data access times, and uses faster memory as much as possible. This is a key factor in GPU computing. By using one GPU device and optimising its memory usage, we improved the computation time by more than 14 times in the 2D simulation, and over six times in the 3D simulation, compared with one CPU. Furthermore, by using three GPUs, we succeeded in accelerating the 3D simulation 10 times.