• 제목/요약/키워드: Seismic load test

검색결과 494건 처리시간 0.026초

Seismic performance of precast assembled bridge piers with hybrid connection

  • Shuang, Zou;Heisha, Wenliuhan;Yanhui, Liu;Zhipeng, Zhai;Chongbin, Zhang
    • Structural Engineering and Mechanics
    • /
    • 제85권3호
    • /
    • pp.407-417
    • /
    • 2023
  • Precast assembled bridge piers with hybrid connection (PASP) use both tendons and socket connections. To study the seismic performance of PASP, a full-scale in-situ test was performed based on an actual bridge project. The elastic-plastic fiber model of PASP was established using finite element software, and numerical analyses were performed to study the influence of prestress degree and socket depth on the PASP seismic performance. The results show that the typical failure mode of PASP under horizontal load is bending failure dominated by concrete cracking at the joint between the column and cushion cap. The cracking of the pier concrete and opening of joints depend on the prestress degree and socket depth. The prestressing tendons and socket connection can provide enough ductility, strength, restoration capability, and bending strength under small horizontal displacements. Although the bearing capacity and post yield stiffness of the pier can be improved to some extent by increasing the prestressing force, ductility is reduced, and residual deformation is increased. Overall, there are reasonable minimum socket depths to ensure the reliability of the socket connection.

비내진 상세를 가진 1:12축소 10층 R.C.골조의 비선형 거동에 관한 실험 연구 (Experimental Study on Nonlinear Behaviors of A 1:12 Scale 10-Story Reinforced Concrete Frame with Nonseismic Details)

  • 이한선;강귀용
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.255-266
    • /
    • 1999
  • 본 연구의 목적은 비내진 상세를 가진 고층 R.C골조의 탄성 및 비탄성 거동을 실험적으로 살펴보는 것이다. 따라서, 국내의 내진 설계규준에 따라 설계 및 시공된 건축물이 선정되었으며, 상사법칙에 따라 1:12의 축소율의 평면 골조모델이 제작되었다. 실험방법은 옥상층의 변위제어에 의해 반전횡하중 실험과 일방향 가력 실험을 수행하였다. 지진효과를 나타내기 위하여, 횡력은 휘플트리를 이용하여 각층에 역삼각형 형태로 분포되었다. 실험으로부터 밑면전단력, 균열양상, 주요부재 단부에서의 국부 회전각 및 층간변위와 층전단력과의 관계를 얻을 수 있었다. 실험결과로부터 비내진 상세를 가진 고층 철근콘크리트 골조의 탄성 및 비탄성 거동에 대해 살펴보았다.

가변형 핑거 조인트를 가지는 신축이음장치의 구조 성능 실험 (An Experiment of Structural Performance of Expansion Joint with Rotation Finger)

  • 유성원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.170-175
    • /
    • 2018
  • 내진 성능 학보를 위해서는 신축이음장치가 지진력에 대하여 적절한 변형이 발생하여 신축이음장치의 파괴를 방지하여야 하는데 최근에 국내에서 신축이음장치의 핑거부에 힌지를 설치하여 교축방향의 지진력에 대한 변위 저항성을 확보한 신제품이 개발되고 있다. 이에 본 논문에서는 가변형 핑거 조인트를 가지는 신축이음장치에 대하여 실물규모의 교축직각방향 하중에 대한 저항성을 실험적으로 평가하였다. 실험결과, 최대 수평변위는 기존 신축이음 실험체의 경우 약 21.1mm, 내진 신축이음 실험체의 경우 51.00mm로 나타났으며, 기존제품은 추가적으로 16.5mm의 솟음이 발생되었다. 기존 신축이음 실험체는 어느 정도의 교축직각 방향의 하중에 대하여 저항한 후, 핑거의 휨 및 전단 변형이 과도하게 발생되며 파단 현상이 발생할 가능성이 있을 것으로 추정된다. 반면에 내진 신축이음 실험체의 경우, 교축 직각방향의 하중에 대하여 하중에 대한 변형을 핑거의 힌지가 흡수하여 신축이음장치 및 상부구조에 응력을 발생시키지 않고 다만 하중 작용방향으로의 수평 변형만 발생시킬 것으로 예상된다.

사용후 연료 건식저장용기 1/8규모 축소모형 지진회전응답해석 (Seismic Rocking Response Analysis of 1/8 Scale Model for a Spent Fuel Storage Cask)

  • 이재한;서기석;구경회;조천형;최병일;이흥영;염성호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.383-389
    • /
    • 2005
  • This research is to develop a seismic response analysis method for a spent fuel storage cask. FEM model is built for the test model of 1/8 scale spent fuel dry storage cask using available 3D contact conditions in ABAQUS/Explicit. Input load for this analysis os a seismic wave of El-centro earthquake, and the friction and damping coefficients in the analysis condition we obtained from the test result. Penalty and kinematic contact methods of ABAQUS are used for mechanical contact formulation. The analysis method was verified for rocking angle obtained by seismic response tests. The kinematic contact method with an adequate normal contact stiffness showed a good agreement with tests.

  • PDF

수평하중에 대한 목조프레임의 결구공법에 대한 연구 - 봉정사(鳳停寺) 극락전(極樂殿)을 대상으로 - (Constructibility Characteristice of Wood Frames of Lateral Cyclic Load - Geungnakjeon Hall of Bongjeongsa Temple -)

  • 이호;이택운
    • 한국산업융합학회 논문집
    • /
    • 제10권4호
    • /
    • pp.255-262
    • /
    • 2007
  • The main purpose of this study is to figure out of seismic structural behaviour of Gukrakjeon of Bongjung-Temple which is the oldest wooden architecture in Korea, and to evaluate in engineering aspect of seismic records. The non-lineal analysis is essential for accurate evaluation of wooden architecture in seismic behaviour. Based on the experimental test with applying cycle forces in joint specimens is focusing on not only to prove the structural characteristics, but also to evaluate damping ratio, As the result of this test, damping ratio is affected not the joint methods but the frame variations. The average damping ratio was 26%.

  • PDF

사용후 연료 건식저장요기 1/8 규모 축소모형 지진응답시험 (Seismic Response Tests of 1/8 Scale Model for a Spent Fuel Dry Storage Cask)

  • 이재한;구경희;서기석;이흥영;최병일;염성호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.55-61
    • /
    • 2005
  • The seismic response tests of a spent fuel dry storage cask model of 1/8 scale are performed for an typical 1940 Elcentro earthquake. This paper focuses on the seismic response test data generation to check the overturing possibility of a storage cask and the slipping displacement on concrete slab bed. A simplified cask model is used to take into account the variations in seismic load magnitude and cask/bed interface friction. The test results show that the model gives an overturning response for an extreme condition.

  • PDF

반복횡하중을 받는 철근콘크리트 원형 교각의 축방향철근 연결상세에 따른 강도저감 및 파괴거동 (Strength Degradation and Failure of Circular RC Bridge Columns with Longitudinal Steel Connection under Cyclic Lateral Load)

  • 이재훈;정철호;고성현;손혁수
    • 콘크리트학회논문집
    • /
    • 제16권1호
    • /
    • pp.111-124
    • /
    • 2004
  • 축방향철근의 연결상세에 따라 7개 그룹 총 21개의 원형나선철근 기둥 시험체를 제작하여 준정적 실험을 수행하였다. 축방향철근 연결상세(단일철근, 겹침이음 및 기계적연결), 심부구속철근비, 축력비 등을 주요 실험변수로 채택하였으며 실험결과 축방향철근 연결상세에 따라 다른 파괴거동을 나타내었고, 내진성능에서도 차이를 나타내었다. 축방향철근이 겹침이음된 시험체의 실험결과, 모든 축방향철근이 겹침이음된 시험체는 내진성능이 상당히 저하되는 것으로 나타났으나, 축방향철근의 $50\%$가 겹침이음된 시험체의 경우 제한적이지만 한정적인 연성능력을 나타내었다. 또한, 축방향철근을 커플러를 사용하여 기계적으로 연결한 시험체는 축방향철근이 단일철근으로 구성된 시험체와 유사한 파괴거동 및 강도저감거동을 나타내었다.

내진테이블의 중량물 낙하 충격실험 (Weight Drop Impact Tests of Earthquake-Proof Table)

  • 엄태성;허석재;박태원;이상현
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.369-378
    • /
    • 2018
  • Full-scale seismic retrofit of old and deteriorated masonry buildings requires a lot of cost and time. In such buildings, installing an emergency evacuation space can be considered as an alternative. In this study, requirements of the earthquake-proof table used as an emergency evacuation space for buildings hit by earthquake are investigated. Load conditions required for the table, including the impact effects due to building debris drop, are explained. To investigate the impact effects in more detail, weight drop test is performed for an prototype earthquake-proof table. In the test, the weight of the falling object and free fall height were considered as the main test parameters. The results showed that the duration of impact is very short (0.0226~0.0779sec), and thus the impact forces increase to 15.8~45.2 times the weight of the falling object. Based on these results, design considerations and performance verification criteria of the earthquake-proof table as an emergency evacuation space are given.

Design of a bracing-friction damper system for seismic retrofitting

  • Lee, Sung-Kyung;Park, Ji-Hun;Moon, Byoung-Wook;Min, Kyung-Won;Lee, Sang-Hyun;Kim, Jinkoo
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.685-696
    • /
    • 2008
  • This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.

비내진 상세를 가진 저층 R.C조의 외부접합부 거동 (Exterior Joint Behavior of Low-Rise Reinforced Concrete Frame with Non-Seismic Detail)

  • 김영문;기찬호;장준호;이세웅;김상대
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.481-486
    • /
    • 1998
  • In this paper, elastic and inelastic behavior of exterior joint of moment-resisting R.C frame with non-seismic detail subjected to reversed cyclic lateral load such as earthquake excitations was investigated. 1/2-scals subassemblage exterior beam-column joint including slab was manufactured based on similitude law. Then, pseudo static test under the displacement control was performed. The results of 1)crack pattern and failure mode, 2)degradation stiffness and strength, energy dissipation capacity from load-displacement hysteresis curve, 3)strain of steel were analysed.

  • PDF