• 제목/요약/키워드: Seismic guidelines

Search Result 164, Processing Time 0.026 seconds

Performance-Based Seismic Design of Reinforced Concrete Building Structures Using Inelastic Displacements Criteria

  • Kabeyaswa, Toshimi
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.61-71
    • /
    • 1998
  • A performance-based seismic design method for reinforced concrete building structures being developed in Japan is outlined. Technical and scientific background of the performance-based design philosophy as well as recently developed seismic design guidelines are is presented, in which maximum displacement response to design earthquake motion is used as the limit-state design criteria. A method of estimating dynamic response displacement of the structures based on static nonlinear analysis is described. A theoretical estimation of nonlinear dynamic response considering the characteristics of energy input to the system is described in detail, which may be used as the standard method in the new performance-based code. A desing philosophy not only satisfying the criteria but also evaluating seismic capacity of the structures is also introduced.

  • PDF

A Study of the Seismic Design Guidelines for Marginal Wharf Structures (잔교식 항만구조물의 내진설계기준에 관한 연구)

  • 김문겸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.188-195
    • /
    • 1998
  • The seismic design guidelines for the pile-supported marginal wharf structures are studied. Various design codes such as AASHTO code or UBC code, which are focused on general structures, may be referred for the design of the wharf structures. However, in developing domestic design code, special consideration should be made concerning the size of the earthquake and the type of the structure. This study aims at the comparison among the various design codes for a specific wharf structure in the process of developing a domestic design code.

  • PDF

Evaluation of Soil Factors for Determination of Seismic Base Shear Force for High Story Buildings During Earthquake (지진시 고층 건물 밑면전단력 산정을 위한 지반계수 결정에 대한 연구)

  • 윤종구;김동수;임종석;손덕길
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.85-97
    • /
    • 2003
  • In this paper, earthquake response analyses were performed using equivalent linear method at the soil sites classified as soil types III and IV in "Standard Design Loads for Buildings" Soil Factors were back-calculated by using spectral accelerations obtained from the analyses and those values are compared with soil factors described in other domestic seismic guidelines. For buildings which have the natural period higher than 0.9 sec, it was possible to use soil factors of soil types II and III instead of those of soil types III and IV, respectively. Therefore, it can be concluded that seismic base shear force can be overestimated in the current seismic guidelines and the improvement is required. required.

Case Study On The Seismic Design Strategy For Post-Quake Functional Buildings In China

  • Peng Liu;Xue Li;Yu Cheng;Xiaoyu Gao;Jinai Zhang;Yongbin Liu
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.251-262
    • /
    • 2023
  • In response to China's "Regulations on the Management of Earthquake Resistance of Building Constructions" on the provision of eight types of important buildings to maintain functional after fortified earthquakes occur, "Guidelines for Seismic Design of post-quake functional buildings (Draft for Review)" distinguishes Class I and Class II buildings, and gives the performance objectives and seismic verification requirements for design earthquakes and severe earthquakes respectively. In this paper, a hospital and a school building are selected as examples to design according to the requirements of fortification of Intensity 8 and 7 respectively. Two design strategies, the seismic isolation scheme and energy dissipation scheme, are considered which are evaluated through elastic-plastic dynamic time-history analysis to meet the requirement of post-quake functional buildings. The results show that the seismic isolation design can meet the requirements in the above cases, and the energy dissipation scheme is difficult to meet the requirements of the "Guidelines" on floor acceleration in some cases, for which the scheme shall be made valid through the seismic resilience assessment. The research in this paper can provide a reference for designers to choose schemes for post-quake functional buildings.

Comparative Study on Seismic Design of Soil-Reinforced Segmental Retaining Walls (블록식 보강토 옹벽의 내진설계에 관한 비교연구)

  • 유충식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.51-61
    • /
    • 2000
  • This paper reviews fundamentals of a pseudo-static seismic design/analysis method for soil-reinforced segmental retaining walls. A comparative study on NCMA and FHWA seismic design guidelines, which are one of the most well known design guidelines for mechanically stabilized earth walls, was also performed. The results demonstrate that there exist significant discrepancies in the results of external stability analysis despite the same calculation model used in the two guidelines, due primarily to different seismic coefficient selection criteria. It is also demonstrated that the internal stability calculation model for NCMA guideline tends to yield larger seismic reinforcement force in the shallower reinforcement layers, resulting in an increased number of reinforcement layers at the top of reinforced wall and increased reinforcement lengths to ensure adequate anchorage capacity. The internal stability calculation model adopted by FHWA guideline, however, leads to redistribution of dynamic force to the lower reinforcement layers and thus results n an opposite trend of NCMA guideline. Findings from this study clearly demonstrate a need for more in-depth studies to develop a generally acceptable design/analysis method.

  • PDF

Performance Based Seismic Design - State of Practice 2012 in the United States of America

  • Klemencic, Ron;Fry, J. Andrew;Hooper, John;Baxter, Robert;Morgen, Brian;Solberg, Kevin;Zaleski, Krzysztof
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.149-154
    • /
    • 2012
  • This paper presents a summary of the state of the practice for Performance Based Seismic Design (PBSD) in the United States. While it is not included in the prescriptive provisions of the United States' building codes, the PBSD procedure has been successfully implemented for two decades. The recent publication of the Guidelines for Performance-Based Seismic Design of Tall Buildings by the Pacific Earthquake Engineering Research Center (PEER) illustrates the fact that the engineering community has embraced this procedure and provides a thoughtful set of recommendations to building designers who intend to implement PBSD. The key parameters currently required for a PBSD also are outlined, such as seismic hazard definition, modeling procedures, and acceptance criteria. These Guidelines will serve as the basis for many PBSD projects in the coming years and as such are a common reference used throughout this paper. Finally, a brief summation of recent PBSD projects in the United States is presented.

Seismic Performance Evaluation of Steel Moment Frame Factory Building with Slender Braces (세장한 가새가 사용된 철골모멘트골조 공장시설물의 내진 성능평가)

  • Kim, Dong Yeon;Cho, Jae Chul;Hwang, Sunwoo;Kim, Taejin;Kim, Jong Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.33-43
    • /
    • 2018
  • 'Seismic Performance Evaluation Method for Existing Buildings (2013)' developed in accordance with the overseas guidelines ASCE 41 - 06 is the most widely used procedure among domestic seismic performance evaluation guidelines in Korea. However, unlike ASCE 41 - 06, it stipulates that the final performance should be derived as the gravity load distribution ratio of the lateral force resistance system in the guideline. Therefore, in the case of a dual steel structure system with slender braces, where the internal moment frame is mostly responsible for the gravity load, the evaluation of slender braces based on gravity load distribution ratio is difficult to be achieved. In this research, we propose an objective evaluation process for such system by evaluating seismic performance for large-scale factory facilities as an example.

Quasi-Static Test for Seismic Performance of R/C Bridge Piers Retrofitted with Glassfibers (준정적실험에 의한 섬유보강된 철근콘크리트 교각의 내진성능 평가)

  • 이대형;이재형;정영수;박진영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.871-876
    • /
    • 2001
  • Recent earthquakes in California and Japan caused extensive damage to highway bridge structures. It is also thought that during probable earthquakes bridge structures in Korea could be failed due to the structural deficiencies, which were nonseismically designed and constructed before 1992. In these regards, innovative strengthening methods have been developed to repair reinforced concrete bridge columns, especially by glassfiber sheet bonding methods which are widely used today. The primary objective of this research is to investigate the seismic behavior of RC bridge columns retrofitted with composite straps and to propose pertinent guidelines of repair and rehabilitation method for earthquake resistant design procedure of RC bridges which are located in low or moderate seismicity regions. Six scaled-down concrete test specimens were made with test variables such as lap splice ratio, axial force ratio, confinement ratio, composite straps in the plastic hinge region. Pertinent design guidelines could be developed for the earthquake resistant design of RC bridge piers retrofitted with glassfibers in low or moderate seismic region.

  • PDF

Seismic Design of Soil-Reinforced Segmental Retaining Walls (블록식 보강토 옹벽의 내진설계)

  • 유충식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.69-83
    • /
    • 1999
  • Soil-reinforced segmental retaining walls(SRW) have been proven to be high earthquake-resistant structure during recent earthquakes in United States and Japan. The mechanicals behavior of the SRWs under seismic loading, however, has not been fully understood. Although the seismic design issues for the civil engineering structures have gained much attention in Korea due to the increase in frequency of earthquake occurrence, the seismic design for the SRWs has not been being implemented. This study has been undertaken with the aim of developing a more rational seismic design/analysis method for soil-reinforced segmental retaining walls. This paper present fundamentals of current seismic design/analysis method and the results of a comparative study between NCMA and FHWA design guidelines, Practical implications of the findings from this study are discussed in great detail.

  • PDF

State of Practice of Performance-Based Seismic Design in Indonesia

  • Sukamta, Davy;Alexander, Nick
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.211-220
    • /
    • 2012
  • The current 2002 Indonesian Seismic Code consists of prescriptive criteria that are intended to result in buildings capable of providing certain levels of performance. However, the actual performance capability of buildings is not assessed as part of the code procedures. Several analysis procedures are allowed, and the state of practice is to use the RSA with six-zone seismic map developed for 475-year earthquake. This code is being revised and will adopt many of the ASCE7-10 provisions and 2475-year earthquake for MCE. The growth of tall buildings compels engineers to look for more optimal lateral system. The use of RC core wall as single system has been adopted by very few engineering firms, which is allowed in the current code but will no longer be the case if the new one is in effect. Other innovative structural system such as core wall and outrigger is not addressed in the proposed new code. Engineers must then resort to NLRHA. Currently, one 50-story building under construction using RC core wall and outrigger has been designed with RSA and employing capacity design principles, then evaluated using NLRHA per TBI Guidelines. Based on the evaluation, the performance of the 50-story building generally still meets the criteria of the TBI Guidelines. The result of the case study is presented in this paper.