• 제목/요약/키워드: Seismic code

검색결과 676건 처리시간 0.025초

Three-Dimensional Seismic Analysis for Spent Fuel Storage Rack

  • Lee, Gyu-Mahn;Kim, Kang-Soo;Park, Keun-Bae;Park, Jong-Kyun
    • Nuclear Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.91-98
    • /
    • 1998
  • Time history analysis is usually performed to characterize the nonlinear seismic behavior of a spent fuel storage rack(SFSR). In the past, the seismic analyses of the SFSR were performed with two-dimensional planar models, which could not account for torsional response and simultaneous multi-directional seismic input In this study, three-dimensional seismic analysis methodology is developed for the single SFSR using the ANSYS code. The 3D- Model can be used to determine the nonlinear behavior of the rack, i.e., sliding, uplifting, and impact evaluation between the fuel assembly and rack, and rack and the pool wall, This paper also reviews the 3-D modeling of the SFSR and the adequacy of the ANSYS for the seismic analysis. AS a result of the adquacy study, the method of ANSYS transient analysis with acceleration time history is suitable for the seismic analysis of highly nonlinear structure such as an SFSR but it isn't appropriate to use displacement time history of seismic input.

  • PDF

현장 및 실내시험에 기초한 홍성지역 지진응답특성 평가 (Evaluation of Seismic Response Characteristics of Hong-Seong Area based on In-Situ and Laboratory Tests)

  • 박덕근;김교원
    • 지질공학
    • /
    • 제11권1호
    • /
    • pp.25-35
    • /
    • 2001
  • 충청남도 홍성지역의 부지응답특성 평가를 위한 연구를 수행하기 위하여 다운홀 및 SASW 기법 등의 현장시험과 공진주/비틂전단시험 등 실내시험을 수행하였다. 이를 바탕으로 홍성지역의 부지특성을 평가하고 지반응답해석을 실시하였다. 홍성지역 현장은 지반은, 상부토층 30m의 평균전단파 속도가 209m/s로 SD 지반으로 결정되었고 응답해석결과 국내 기준과 잘 일치되는 부분도 있었으나, 구조물 주기에 따른 응답스펙트롬의 특정 주기에서 국내 기준보다 크게 증폭되는 현상도 발견되었다.

  • PDF

Characteristics of Korean Earthquakes and Research Activities for the Seismic Hazard Mitigation in Korea

  • Chang, Sung-Pil
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.1-12
    • /
    • 1998
  • Korea is not considered to be one of the safe zones for earthquakes any more. According to the records of the historical records and recent earthquake events in Korea, the possibillty of disastrous seismic hazards cannot be ignored, Korea Earthquake Engineering Research Center (KEERC) and Earthquake Engineering Society of Korea(EESK) have been established by that consensus. In this paper, historical earthquake records and seismicity in Korea are reviewed. And the research activities and the research system for the earthquake hazards mitigation of KEERC are introduced and the efforts of ESSK to renovate seismic design code system and to optimize the protection levels against earthquake disasters is explained.

  • PDF

Theoretical analysis on vibration characteristic of a flexible tube under the interaction of seismic load and hydrodynamic force

  • Lai, Jiang;He, Chao;Sun, Lei;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.654-659
    • /
    • 2020
  • The reliability of the spent fuel pool instrument is very important for the security of nuclear power plant, especially during the earthquake. The effect of the fluid force on the vibration characteristics of the flexible tube of the spent fuel pool instrument needs comprehensive analysis. In this paper, based on the potential flow theory, the hydrodynamic pressures acting on the flexible tube were obtained. A mathematical model of a flexible tube was constructed to obtain the dynamic response considering the effects of seismic load and fluid force, and a computer code was written. Based on the mathematical model and computer code, the maximum stresses of the flexible tube in both safe shutdown earthquake and operating basis earthquake events on the spent fuel pool with three typical water levels were calculated, respectively. The results show that the fluid force has an obvious effect on the stress and strain of the flexible tube in both safe shutdown earthquake and operating basis earthquake events.

내진설계를 위한 지진 입력하중 조정 방법 (Method of the Calibration of earthquake Ground Motions for Seismic Design)

  • 공도환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.20-27
    • /
    • 1998
  • In the current seismic design codes design earthquake is usually defined as the earthquake with the 90 percent probability of not being exceeded in the life time of a structure which is assumed as 50 years equivalent to the earthquake with 475 year recurrence period. However the life time of tall building structures may be much longer than 50 yers. The current seismic design code requires the modal analysis or dynamic time history analysis for the buildings with the height exceeding a certain height limit. The objective of this study is to collect the earthquake ground motion(EQGM) which can be used for dynamic time history analysis for tall buildings. For this purpose linear elastic design response spectrum (LEDRS) in the code is scaled to account for the recurrence period of the design earthquake. The earthquake ground motions which has been recorded are calibrated to fit the scaled LEDRS. The set of calibrated EQGM can be treated as design EQGM for the design of tall building with longer lifetime than ordinary building.

  • PDF

지반주기를 고려한 다층지반의 평균전단파속도 추정 방법 평가 (Evaluation of Average Shear-wave Velocity Estimation Methods of Multi-layered Strata Considering Site Period)

  • 김동관
    • 한국지진공학회논문집
    • /
    • 제23권3호
    • /
    • pp.191-199
    • /
    • 2019
  • To calculate proper seismic design load and seismic design category, the exact site class for construction site is required. At present, the average shear-wave velocity for multi-layer soil deposits is calculated by the sum of shear-wave velocities without considering of vertical relationship of the strata. In this study, the transfer function for the multi-layered soil deposits was reviewed on the basis of the wave propagation theory. Also, the transfer function was accurately verified by the finite element model and the eigenvalue analysis. Three methods for site period estimation were evaluated. The sum of shear-wave velocities underestimated the average shear-wave velocities of 526 strata with large deviations. The equation of Mexican code overestimated the average shear-wave velocities. The equation of Japanese code well estimated the average shear-wave velocities with small deviation.

진동대 실험을 통한 외부보강형 판넬조립식 물탱크의 내진성능평가 (Seismic Performance Evaluation of Externally Reinforced Panel Water Tank Using Shaking Table Tests)

  • 박세준;원성환;최문석;김상효;정진환
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.151-157
    • /
    • 2013
  • In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.

기존 철근콘크리트 건축물의 내진성능 평가 (Evaluation of the Seismic Performance of Existing Building Structures)

  • 우운택
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.239-244
    • /
    • 2000
  • The necessity of the seismic performance evaluation of existing building structures is raised through the Taiwan earthquake in 1999. In this study, the methods of seismic performance evaluation of existing building structures in U.S.A. and Japan were reviewed, applied them to the three-story office building structures in Seoul. It is found out that it is possible to establish the seismic performance evaluation index of RC structure which meet Korean seismic code. Also it is concluded that if sufficient experimental and analytical data could be obtained, a reliable index for the evaluation of seismic performance of existing structures should be established in Korea.

  • PDF

Experimental study on seismic performances of steel framebent structures

  • Liang, Jiongfeng;Gu, Lian S.;Hu, Ming H.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1111-1123
    • /
    • 2016
  • To study seismic performance of steel frame-bent structure, one specimen with one-tenth scale, three-bay, and five-story was tested under reversed cyclic lateral load. The entire loading process and failure mode were observed, and the seismic performance indexes including hysteretic loops, skeleton curve, ductility, load bearing capacity, drift ratio, energy dissipation capacity and stiffness degradation were analyzed. The results show that the steel frame-bent structure has good seismic performance. And the ductility and the energy dissipation capacity were good, the hysteresis loops were in spindle shape, which shape were full and had larger area. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. It can be helpful to design this kind of structure in high-risk seismic zone.

Evaluation of seismic performance factors for steel DIAGRID structural system design

  • Lee, Dongkyu;Shin, Soomi;Ju, Youngkyu
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.735-755
    • /
    • 2016
  • This article presents a proposed analytical methodology to determine seismic force-resisting system R-values for steel diagrid framed systems. As current model building codes do not explicitly address the seismic design performance factors for this new and emerging structural system, the purpose of this study is to provide a sound and reliable basis for defining such seismic design parameters. An approach and methodology for the reliable determination of seismic performance factors for use in the design of steel diagrid framed structural systems is proposed. The recommended methodology is based on current state-of-the-art and state-of-the practice methods including structural nonlinear dynamic analysis techniques, testing data requirements, building code design procedures and earthquake ground motion characterization. In determining appropriate seismic performance factors (R, ${\Omega}_O$, $C_d$) for new archetypical building structural systems, the methodology defines acceptably low values of probability against collapse under maximum considered earthquake ground shaking.