• 제목/요약/키워드: Seismic Isolation Test

검색결과 109건 처리시간 0.032초

교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석 (Dynamic Analysis far Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot)

  • 박동욱;윤정방;이인원;강용우;손만길
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.320-328
    • /
    • 2001
  • Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests were performed on two kinds of aseismic bridge bearings : Hydampot (hysteretic damping bearing) and Dynapot . Then, the dynamic analysis was carried out far a bridge using the experimental results to estimate the seismic performance of the bearings. Analysis was performed for four types oi earthquake loadings. The results of the dynamic test and theoretical analysis indicate that the performance of both bridge bearings is appropriate fur the earthquake loading.

  • PDF

지진격리 강재 케이블 교량의 다지점 진동대 실험 (Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge)

  • 김성도;안진희;공영이;최형석;정진환
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.161-171
    • /
    • 2015
  • A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.

원추형 마찰진자베어링의 내진성능평가 (Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System)

  • 전법규;장성진;박경록;김남식;정득영
    • 한국지진공학회논문집
    • /
    • 제15권2호
    • /
    • pp.23-33
    • /
    • 2011
  • 본 연구에서는 중요 통신장비의 지진발생시 파손 및 성능저하를 방지하기 위하여 구조물로 전달되는 가속도를 조절할 수 있는 CFPBS(Cone-type Friction Pendulum Bearing System:원추형 마찰진자베어링)를 개발하고 내진성능을 검증하였다. CFPBS는 기존의 FPS(Friction Pendulum System)와 다르게 원추형으로 제작되었으며 보다 큰 마찰력을 얻기 위하여 마찰면에 패턴을 음각하였다. CFPBS의 고유성능을 파악하기 위하여 4개의 CFPBS가 하나의 개체를 이루도록 제작된 지진격리장치를 이용하여 자유진동시험을 수행하였다. 운동방정식으로부터 유도된 CFPBS의 이론식과 Newmark-${\beta}$ Method를 이용하여 내진성능을 검증하기위한 MATLAB7.0 기반의 동적 수치해석프로그램을 제작하였으며 CFPBS의 제작 시 원하는 성능을 발휘할 수 있도록 간략화된 CFPBS의 설계식을 제안하였다. 수치해석을 통한 CFPBS의 내진성능평가를 위하여 건축구조설계기준(KBC-2005)의 최대지진규모에 해당하는 인공지진파를 생성하고 검증하였다. El Centro NS(1940)와 Kobe NS(1995), 인공지진파 등을 사용하여 CFPBS의 상부질량과 경사각을 매개변수로 하는 수치해석을 수행하였다. 수치해석의 결과를 토대로 CFPBS의 내진성능을 평가하였으며 수치해석의 결과와 설계식을 이용하여 동일한 조건에서 얻어진 결과를 비교분석하였다.

Nonlinear response of r.c. framed buildings retrofitted by different base-isolation systems under horizontal and vertical components of near-fault earthquakes

  • Mazza, Fabio;Mazza, Mirko;Vulcano, Alfonso
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.135-144
    • /
    • 2017
  • Near-fault ground motions are characterized by high values of the ratio between the peak of vertical and horizontal ground accelerations, which can significantly affect the nonlinear response of a base-isolated structure. To check the effectiveness of different base-isolation systems for retrofitting a r.c. framed structure located in a near-fault area, a numerical investigation is carried out analyzing the nonlinear dynamic response of the fixed-base and isolated structures. For this purpose, a six-storey r.c. framed building is supposed to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by current Italian code in a high-risk seismic zone. In particular, elastomeric (e.g., high-damping-laminated-rubber bearings, HDLRBs) and friction (e.g., steel-PTFE sliding bearings, SBs, or friction pendulum bearings, FPBs) isolators are considered, with reference to three cases of base isolation: HDLRBs acting alone (i.e., EBI structures); in-parallel combination of HDLRBs and SBs (i.e., EFBI structures); FPBs acting alone (i.e., FPBI structures). Different values of the stiffness ratio, defined as the ratio between the vertical and horizontal stiffnesses of the HDLRBs, sliding ratio, defined as the global sliding force divided by the maximum sliding force of the SBs, and in-plan distribution of friction coefficient for the FPs are investigated. The EBI, EFBI and FPBI base-isolation systems are designed assuming the same values of the fundamental vibration period and equivalent viscous damping ratio. The nonlinear dynamic analysis is carried out with reference to near-fault earthquakes, selected and scaled on the design hypotheses adopted for the test structures.

면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험 (Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building)

  • 천영수
    • 토지주택연구
    • /
    • 제2권3호
    • /
    • pp.287-297
    • /
    • 2011
  • 본 논문은 적층고무형베어링을 갖는 15층 면진 무량판 아파트건물의 내진거동을 진동대실험을 통하여 검증한 결과를 제시하고 있다. 진동대실험은 중국의 CABR에서 1/10규모의 모형실험체를 대상으로 수행되었다. 실험의 진행은 4개의 지진파를 이용하여 X, Y, X+Y방향으로 다양한 크기의 지진동이 입력되었다. 실험결과, 비 면진건물은 중진레벨에서 진동주기가 현저히 감소하고, 비선형적인 거동을 보였으며, 가속도가 건물의 높이에 따라 현저하게 증가하고, 층간변위도 허용한계를 넘는 거동을 보였다. 반면, 면진건물은 중진레벨에서 거의 일정한 진동주기의 탄성적인 거동을 나타내었으며, 지진하중과 층 가속도가 현저하게 감소하는 응답을 나타내었다. 또한 면진층의 변위는 허용범위 내에서 거동하고, 층간변위는 무시할 수 있을 만큼 작은 강체거동을 나타내었다. 결론적으로 면진은 건물에 대한 지진의 영향을 감소시키는데 매우 효과적이며, 층 가속도의 감소를 통하여 사용성을 증가시키고, 건물 내 설비 등을 안전하게 보호할 수 있음이 입증되었다.

점성감쇠형 면진장치에 관한 실험적 연구 (Experimental Study on Viscous Fluid Damper for Seismic Base Isolation System)

  • 정민기;박진일;권형오;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.590-595
    • /
    • 1998
  • This study was performed to obtain a numerical model for a viscous fluid damper from an experimental testing. The input signals for displacement were chosen as two type : a triangular and a sinusoidal forms. The performing test parameters were the area of the resistant plate and the oil film thickness of the viscous fluid and the temperature effect was neglected. The numerical model was established by assuming to behavior as an non-Newtonian fluid. The test results were summarized by the equation of F = 0.0308A(V/d)$^{0.51}$25/. Using the obtainal formula, the procedure to apply the viscous damper for a real structure design was introduced..

  • PDF

Experimental study on the compressive stress dependency of full scale low hardness lead rubber bearing

  • Lee, Hong-Pyo;Cho, Myung-Sug;Kim, Sunyong;Park, Jin-Young;Jang, Kwang-Seok
    • Structural Engineering and Mechanics
    • /
    • 제50권1호
    • /
    • pp.89-103
    • /
    • 2014
  • According to experimental studies made so far, design formula of shear characteristics suggested by ISO 22762 and JEAG 4614, representative design code for Lead Rubber Bearing(LRB) shows dependence caused by changes in compressive stress. Especially, in the case of atypical special structure, such as a nuclear power structure, placement of seismic isolation bearing is more limited compared to that of existing structures and design compressive stress is various in sizes. As a result, there is a difference between design factor and real behavior with regards to shear characteristics of base isolation device, depending on compressive stress. In this study, a full-scale low hardness device of LRB, representative base isolation device was manufactured, analyzed, and then evaluated through an experiment on shear characteristics related to various compressive stresses. With design compressive stress of the full-scale LRB (13MPa) being a basis, changes in shear characteristics were analyzed for compressive stress of 5 MPa, 10 MPa, 13 MPa, 15 MPa, and 20 MPa based on characteristics test specified by ISO 22762:2010 and based on the test result, a regression analysis was made to offer an empirical formula. With application of proposed design formula which reflected the existing design formula and empirical formula, trend of horizontal characteristics was analyzed.

Rocking behavior of bridge piers with spread footings under cyclic loading and earthquake excitation

  • Hung, Hsiao-Hui;Liu, Kuang-Yen;Chang, Kuo-Chun
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1001-1024
    • /
    • 2014
  • The size of spread footings was found to be unnecessarily large from some actual engineering practices constructed in Taiwan, due to the strict design provisions related to footing uplift. According to the earlier design code in Taiwan, the footing uplift involving separation of footing from subsoil was permitted to be only up to one-half of the foundation base area, as the applied moment reaches the value of plastic moment capacity of the column. The reason for this provision was that rocking of spread footings was not a favorable mechanism. However, recent research has indicated that rocking itself may not be detrimental to seismic performance and, in fact, may act as a form of seismic isolation mechanism. In order to clarify the effects of the relative strength between column and foundation on the rocking behavior of a column, six circular reinforced concrete (RC) columns were designed and constructed and a series of rocking experiments were performed. During the tests, columns rested on a rubber pad to allow rocking to take place. Experimental variables included the dimensions of the footings, the strength and ductility capacity of the columns and the intensity of the applied earthquake. Experimental data for the six circular RC columns subjected to quasi-static and pseudo-dynamic loading are presented. Results of each cyclic loading test are compared against the benchmark test with fixed-base conditions. By comparing the experimental responses of the specimens with different design details, a key parameter of rocking behavior related to footing size and column strength is identified. For a properly designed column with the parameter higher than 1, the beneficial effects of rocking in reducing ductility and the strength demand of columns is verified.

섬유보강 탄성받침의 설계 및 실험적 해석 (Design and Experimental Analysis of Fiber Reinforced Elastomeric Isolator)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2026-2033
    • /
    • 2002
  • The purpose of this study is to investigate the effect of mechanical properties of the FREI using horizontal stiffness and vertical stiffness by experiments. Two kinds of FREI are designed and fabricated. The steel plates of SREI are replaced with fibers in order to reduce the cost of fabrication and installation. At first, the Nylon fiber is adopted as feasibility study of FREI. The experimental results of Nylon FREI and SREI show that the vertical stiffness of Nylon FREI is lower than SREI, and effective damping is two times higher than SREI. Carbon is adopted, by these rusults, as strong reinforcement than Nylon and full scale of carbon FREI was designed and fabricated. By the experimental test results, it is shown that the vertical stiffness of carbon FREI is three times higher than SREI, and two times higher in effective damping. As a result, the proposed FREI can replace the SREI as a seismic isolator.

대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계 (Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement)

  • 김홍배;임종민;양호순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF