• Title/Summary/Keyword: Seismic Isolation Test

Search Result 109, Processing Time 0.027 seconds

Experimental Techniques for Evaluating Seismic Performance of Base-Isolated Structure (기초격리된 구조물의 내진성능평가를 위한 실험기법)

  • 윤정방;정우정;김남식;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.45-58
    • /
    • 1997
  • This paper describes a series of shaking table and pseudodynamic tests for evaluation of seismic performance of base-isolated structures subjected to various seismic earthquake inputs. The main objectives of this study are : (1) evaluation of the effectiveness of base-isolation systems for low-rise structures against severe seismic loads through shaking table tests, (2) verification of the substructuring pseudodynamic test method for the base-isolated structures in comparison with the shaking table test results. In the shaking table test, a quarter scaled three-story structure base-isolated by laminated rubber bearings is tested. In the pseudodynamic test, only the laminated rubber bearing s are tested using the substructuring technique, while the concurrent seismic responses of the superstructure are computed using on-line numerical integration. Comparison with the shaking table test results indicates that the substructuring pseudodynamic test method is very effective for determining the dynamic responses of the base-isolated structure.

  • PDF

Dynamic Analysis for Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot (교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석)

  • 윤정방;박동욱;이동하;안창모
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.465-474
    • /
    • 2001
  • Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests was performed on HDB (Hysteretic Damping Bearing) and Dynapot. Then, the dynamic analysis was carried out for a bridge using the experimental results to estimate the seismic performance of bearings. Analysis for bridge was performed for four types of earthquake loadings. The result of dynamic test and theoretical analysis indicate that the performance of HDB and Dynapot is appropriate for the earthquake loading.

  • PDF

Evaluation of Seismic Responses of Isolated Bridges Considering the Flexibility of Piers (교각의 강성을 고려한 지진격리교량의 응답특성 평가)

  • Seo, Hyun-Woo;Kim, Nam-Sik;Cheung, Jin-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.662-665
    • /
    • 2004
  • In this paper, based on shaking table test results on a seismically isolated bridge model, an inelastic numerical model is refined by using Bouc-Wen model representing the hysteretic behavior of isolators. Seismic responses of isolated bridges are numerically investigated varying with relative stiffness ratios, which is a ratio of the effective stiffness of isolator to the lateral stiffness of bridge pier. From the results, it is found that an adequate range of relative stiffness ratio could be defined for seismic design of isolated bridges without considering the flexibility of piers.

  • PDF

Shaking Table Test of Rectangular Liquid Container with Base-Isolation System (사각형 면진유체저장조의 진동대실험)

  • 전영선;최인길
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.122-129
    • /
    • 1995
  • The seismic behavior of a rectangular liquid container with high damping laminated rubber bearing is investigated through the scaled model tests. The results are compared with those for non-isolated model, and those by analytical methods. It is shown that the optimum dynamic properties of isolation system can reduce the acceleration response in the superstructure significantly and prevent the amplification of sloshing height.

  • PDF

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.

Investigating the Influence of Rate Dependency and Axial Force on the Seismic Performance Evaluation of Isolation Bearing (면진받침의 내진성능평가를 위한 실험 시 속도의존성과 수직하중의 영향)

  • Minseok Park;Yunbyeong Chae;Chul-Young Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.22-29
    • /
    • 2023
  • In the evaluation of seismic performance for structural materials and components, the loading rate and axial force can have a significant impact. Due to time-delay effects between input and output displacements, It is difficult to apply high-rate displacement in cyclic tests and hybrid simulations. Additionally, the difficulty of maintaining a consistent vertical load in the presence of lateral displacement has limited fast and real-time tests performed while maintaining a constant vertical load. In this study, slow, fast cyclic tests and real-time hybrid simulations were conducted to investigate the rate dependency and the influence of vertical loads of Isolation Bearing. In the experiment, the FLB System including an Adaptive Time Series (ATS) compensation and a state estimator was constructed for real-time control of displacement and vertical load. It was found that the vertical load from the superstructure and loading rate can have a significant impact on the strength of the seismic isolation bearing and its behavior during an earthquake. When conducting experiments for seismic performance evaluation, they must be implemented to be similar to reality. This study demonstrates the excellent performance of the system built and used for seismic performance evaluation and enables accurate and efficient seismic performance evaluation.

Analysis of soft deformation limitation of base-isolated structures

  • Jinwei Jiang;Baoyang Yang
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.1-15
    • /
    • 2024
  • Isolation technology has been proven effective in reducing the seismic response of superstructures, where most of the deformation is concentrated in the isolation layer. However, in cases of earthquakes with intensities surpassing the fortification level of the area, or severe near-fault earthquakes, the isolation layer may experience excessive deformation, resulting in damage to the isolation bearings or collisions with the retaining wall or surrounding buildings. In this study, a finite element model using ABAQUS is established and compared with experimental test results to deeply investigate the influence of limit devices on the isolation layer and its response to the superstructure. The findings reveal that a larger limiter stiffness and a smaller reserved gap can achieve a more effective limiting effect. Nevertheless, a smaller reserved gap and a larger limiter stiffness may result in increased response of the superstructure. Therefore, rational selection of the reserved gap and limiter stiffness is crucial to reduce the acceleration response.

Finite Element Analysis of Seismic Isolation Bearing (면진베어링 유한요소해석)

  • Lee, Jae-Han;Yoo, Bong;Koo, Gyeong-Hoi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.45-51
    • /
    • 1996
  • The combined shear and compression behaviors of seismic isolation rubber bearings are analyzed using the hyperelasticity material option of the ABAQUS computer program. The purpose of the analysis is to predict the behavior of laminated rubber bearing before the several tests. Some kinds of strain energy density functions are used as constitutive law for rubber itself having the hyperelasticity. The results are compared with test data peformed in Italy The analysis results show a little different with experimental results depending on the constitutive model and the refinement of finite element. The high order form of strain energy density functions results in good agreements and the mesh refinement above two for one rubber layer is enough to get good results.

  • PDF

Structural Analysis of Seismic Isolation Bearings for Liquid Metal Reactor (액체금속로용 면진베어링의 구조해석)

  • Kim, Jong-In;Yoo, Bong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.186-192
    • /
    • 1993
  • Proto-type seismic isolation rubber bearings are investigated through nonlinear hyperelasticity finite elements using the ANSYS general purpose structural analysis code. The purpose of the analysis was to determine the maximum horizontal strain range which can be obtained with a 250KN hydraulic actuator. A Mooney-Rivlin strain energy density function was used as a constitutive law for rubber. The results are compared with the test data available in the literature and found to in good agreement only in the higy strain range. The analysis results can be used with conservatism to predict the necessary force required to a specified displacement such as the purpose of this analysis. However, more precise constitutive model will be required to simulate the bearing behavior with accuracy in the mid-range strain.

  • PDF

Seismic Performance of Reinforced Concrete Frame Retrofitted with Opening-Isolated Type System (개구부 격리형 시스템으로 보강된 철근콘크리트 골조의 내진성능)

  • Park, Wan-Shin;Kim, Sun-Woo;Jung, Hyun-Seok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.137-144
    • /
    • 2020
  • The purpose of this study is to experimentally evaluate the effect of improving seismic performance by applying the details of seismic reinforcement to the reinforced concrete frame with non-seismic details while maintaining the original opening shape. In this study, based on CF specimens with specific seismic details, a total of four full scale specimens were designed and fabricated. The main variables are the width and spacing of steel dampers installed in the upper and lower parts of seismic reinforcement details, and the presence or absence of torsion springs installed in the hinges. As a result of the test, it was evaluated to be helpful for seismic retrofit and opening isolation of steel dampers installed at the upper and lower parts of the seismic reinforcement details and torsion springs installed at the joints. In particular, CFR2S specimens with torsion springs showed the best performance in terms of strength, stiffness and energy dissipation capacity with increasing displacement angle.