• 제목/요약/키워드: Seismic Coefficient

Search Result 308, Processing Time 0.024 seconds

Experimental Structural Performance Evaluation of Precast-Buckling Restrained Brace Reinforced With Engineering Plastics (공업용 플라스틱으로 보강된 비좌굴가새의 실험적 구조성능평가)

  • Kim, Yu-Seong;Kim, Gee-Chul;Kang, Joo-Won;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.43-52
    • /
    • 2020
  • In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.

Seismic Evaluation of Shear Wall System by Nonlinear Static Analysis Procedures (비선형 정적 해석을 통한 벽식구조물의 내진성능 평가)

  • 안성기;송정원;송진규;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.63-68
    • /
    • 2000
  • Concrete is popular as a building material, however it is inherently brittle and performs poorly during earthquakes if nor reinforced properly. Traditional retrofit design techniques assume that buildings respond elastically to earthquakes. This assumption simplifies the analysis procedure but can lead to an erroneous conclusion. The complete nonlinear time history analysis is considered overly complex and impractical for general use. Simplified nonlinear analysis methods, referred to as nonlinear static analysis procedures, include the capacity spectrum method(CSM) developed in detail at ATC-40 and the displacement coefficient method(DCM) utilized at FEMA-273. In this study wall APT system. The results were compared and analyzed. The program used was neaMAX-3D to express nonlinear material.

  • PDF

Evaluation and analytical approximation of Tuned Mass Damper performance in an earthquake environment

  • Tributsch, Alexander;Adam, Christoph
    • Smart Structures and Systems
    • /
    • v.10 no.2
    • /
    • pp.155-179
    • /
    • 2012
  • This paper aims at assessing the seismic performance of Tuned Mass Dampers (TMDs) based on sets of recorded ground motions. For the simplest configuration of a structure-TMD assembly, in a comprehensive study characteristic response quantities are derived and statistically evaluated. Optimal tuning of TMD parameters is discussed and evaluated. The response reduction by application of a TMD is quantified depending on the structural period, inherent damping of the stand-alone structure, and ratio of TMD mass to structural mass. The effect of detuning on the stroke of the TMD and on the structural response is assessed and quantified. It is verified that a TMD damping coefficient larger than the optimal one reduces the peak deflection of the TMD spring significantly, whereas the response reduction of the main structure remains almost unaffected. Analytical relations for quantifying the effect of a TMD are derived and subsequently evaluated. These relations allow the engineer in practice a fast and yet accurate assessment of the TMD performance.

Shaking Table Test of the Model of Five-story Stone Pagoda of Sang-Gye-Sa Mounted on Base Isolation Systems (쌍계사 오층석탑모델에 대한 지진격리효과 진동대실험)

  • 김재관;이원주;김영중;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.331-338
    • /
    • 2001
  • Seismic performances of the base isolated model of Five Story Stone Pagoda were studied through shaking table tests. Friction pendulum system (FPS), Pure-friction system with laminated rubber bearing (LRB) and Ball with rubber bearing were selected fur the comparison of performances. Performances of specially designed isolation systems were tested dynamically using shaking table. The test results of isolated model are compared with those of fixed base model. Compared with fixed base model, the isolated model showed that it could withstand much higer intensity of earthquake motion. The Effective Peak Ground Acceleration (EPGA) value of isolated model when the top component tipped over was above twice of that value in case of fixed base model. According to the additional test results, the lower value of coefficient of friction than that of common frictional base isolation systems is more effective to protect the piled multi-block system of Pagoda against moderate intesity of ground motion.

  • PDF

Dynamic Instability Behavior of Diagonally Braced Steel Frames under Seismic Excitation (지진하중을 받는 대각선 철골 중심가새골조의 동적 불안정 거동)

  • Lee, Cheol-Ho;Kim, Jung-Jae
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.129-136
    • /
    • 2005
  • Concentrically braced steel frames are considered as being quite prone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically braced frames by dynamic instability becomes a highly probable. In this study, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel frames by considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis was conducted to check the robustness of the proposed index based on simulated ground motions. The analysis results showed that the dynamic instability index proposed predicts the collapse potential more consistently than the conventional one. Dynamic instability was triggered when the index value was close to 0.7.

  • PDF

Seismic Analysis of Bridges Accounting for Soil-Pile-Structure Interaction (지반-말뚝-구조물 상호작용을 고려한 교량구조물의 지진해석)

  • Kim, Moon-Kyun;Lim, Yun-Mook;Cho, Kyung-Hwan;Kim, Ji-Sun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.405-412
    • /
    • 2005
  • In this study, a numerical method for soil-pile-structure interaction problems in multi-layered half-plane is developed. The total soil-pile-structure interaction system is divided into two parts namely, nonlinear structure part and linear soil-pile interaction parts. In the structure field, the general finite element method is introduced to solve the dynamic equation of motion for the structure. In the soil-pile structure interaction part, physical model consisting of lumped parameter, which is frequency dependent coefficient and determined by rigorous analysis method is introduced. Using proposed analysis procedure, the nonlinear behavior of structure considering soil-structure interaction can be efficiently determined in time domain and the analysis cost is dramatically reduced.

  • PDF

FE Analysis on In-Plane Behavior of Unreinforced Masonry Walls (비보강 조적벽체의 면내거동에 대한 FEM 해석)

  • 김장훈;권기혁
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.45-52
    • /
    • 2001
  • A series of unreinforced masonry (URM) walls were analytically investigated for a limited version of seismic in-plane performance. For this URM walls were assumed to be an elastic continuum and modeled as isotropic plane stress elements within which the nature of cracking was propagated. Accordingly, cracking mode of behavior in URM was modeled by smeared-crack approach. Total of 70 cases were considered for various parameters such as axial load ratio, aspect ratio and effective section area ratio due to the existence of opening, etc. The analysis results indicated a general tendency in base shear coefficient and deformability of URM walls for these variables.

  • PDF

Statistical evaluation of the monotonic models for FRP confined concrete prisms

  • Hosseinpour, Farid;Abdelnaby, Adel E.
    • Advances in concrete construction
    • /
    • v.3 no.3
    • /
    • pp.161-185
    • /
    • 2015
  • FRP confining is a widely used method for seismic retrofitting of concrete columns. Several studies investigated the stress-strain behavior of FRP confined concrete prisms with square and rectangular sections both experimentally and analytically. In some studies, the monotonic stress-strain behavior of confined concrete was investigated and compressive strength models were developed. To study the reliability of these models, thorough statistical tests are required. This paper aims to investigate the reliability of the presented models using statistical tests including t-test, wilcoxon rank sum test, wilcoxon signed rank test and sign test with a level of significance of 5%. Wilk Shapiro test was also employed to evaluate the normality of the data distribution. The results were compared for different cross section and confinement types. To see the accuracy of the models when there were no significant differences between the results, the coefficient of confidence was used.

Comparison of Energy Demand in Multi-Story Buckling Restrained Braced Frame and Equivalent SDOF System (다층 비좌굴 가새골조와 등가 단자유도계의 에너지 요구량의 비교)

  • 김진구;원영섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.2
    • /
    • pp.173-182
    • /
    • 2003
  • In equivalent static nonlinear analysis and in energy-based design, the structures are generally transformed into an equivalent SDOF system. In this study the seismic energy demands in multi story structures, such as three-, eight-, and twenty-story steel moment-resisting frames(MRF), buckling restrained braced frames(BRBF) and a damage tolerant braced frame(DTBF), are compared with those of equivalent single degree of freedom(ESDOF) systems. Sixty earthquake ground motions recorded In different soil conditions, which are soft rock, soft soil, and neat fault, were used to compute the input and hysteretic energy demands in model structures. In case the modal mass coefficient is less than 0.8, the effects of higher modes are considered in the process of converting into ESDOF According to the analysis results, the hysteretic and input energies obtained from 3 story and 8 story MRF and DTBF agreed well with the results from analysis of equivalent SDOF systems. However in the 20 story BRBF the results from ESDOF underestimated those obtained from the original structures.

A simplified method for estimating the fundamental period of masonry infilled reinforced concrete frames

  • Jiang, Rui;Jiang, Liqiang;Hu, Yi;Ye, Jihong;Zhou, Lingyu
    • Structural Engineering and Mechanics
    • /
    • v.74 no.6
    • /
    • pp.821-832
    • /
    • 2020
  • The fundamental period is an important parameter for seismic design and seismic risk assessment of building structures. In this paper, a simplified theoretical method to predict the fundamental period of masonry infilled reinforced concrete (RC) frame is developed based on the basic theory of engineering mechanics. The different configurations of the RC frame as well as masonry walls were taken into account in the developed method. The fundamental period of the infilled structure is calculated according to the integration of the lateral stiffness of the RC frame and masonry walls along the height. A correction coefficient is considered to control the error for the period estimation, and it is determined according to the multiple linear regression analysis. The corrected formula is verified by shaking table tests on two masonry infilled RC frame models, and the errors between the estimated and test period are 2.3% and 23.2%. Finally, a probability-based method is proposed for the corrected formula, and it allows the structural engineers to select an appropriate fundamental period with a certain safety redundancy. The proposed method can be quickly and flexibly used for prediction, and it can be hand-calculated and easily understood. Thus it would be a good choice in determining the fundamental period of RC frames infilled with masonry wall structures in engineering practice instead of the existing methods.