• Title/Summary/Keyword: Seismic Capacity Performance

Search Result 906, Processing Time 0.027 seconds

Evaluation of the seismic performance of special moment frames using incremental nonlinear dynamic analysis

  • Khorami, Majid;Khorami, Masoud;Motahar, Hedayatollah;Alvansazyazdi, Mohammadfarid;Shariati, Mahdi;Jalali, Abdolrahim;Tahir, M.M.
    • Structural Engineering and Mechanics
    • /
    • v.63 no.2
    • /
    • pp.259-268
    • /
    • 2017
  • In this paper, the incremental nonlinear dynamic analysis is used to evaluate the seismic performance of steel moment frame structures. To this purpose, three special moment frame structure with 5, 10 and 15 stories are designed according to the Iran's national building code for steel structures and the provisions for design of earthquake resistant buildings (2800 code). Incremental Nonlinear Analysis (IDA) is performed for 15 different ground motions, and responses of the structures are evaluated. For the immediate occupancy and the collapse prevention performance levels, the probability that seismic demand exceeds the seismic capacity of the structures is computed based on FEMA350. Also, fragility curves are plotted for three high-code damage levels using HASUS provisions. Based on the obtained results, it is evident that increase in the height of the frame structures reduces the reliability level. In addition, it is concluded that for the design earthquake the probability of exceeding average collapse prevention level is considerably larger than high and full collapse prevention levels.9.

Seismic Performance Evaluation of Unreinforced Masonry Walls with Additional Boundary RC Frames (RC 경계골조를 설치한 신축 비보강 조적벽체의 내진성능 평가)

  • You, Young-Chan;Kim, Min-Sun;Lee, Hyun-Jee
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.27-35
    • /
    • 2018
  • The purpose of this study is to examine the effects of boundary RC frame(composed of one tie-beam and two tie-columns) on seismic performance of unreinforced masonry walls to suggest alternative way for seismic design of unreinforced masonry wall structures. Two test specimens are prepared, one is a typical unreinforced masonry wall and another is alternative unreinforced masonry wall with additional boundary RC frame. The structural experiments were carried out to evaluate the difference of seismic resistance performance between two test specimens with or without the boundary RC frames. From the test results, it was found that the failure mode of unreinforced masonry wall fundamentally changed from 'brittle' to 'ductile' by the installing of boundary RC frames. And, the maximum load and energy dissipation capacity of the test specimen with boundary RC frame was increased about 1.6~1.7 and 2~3 times respectively compared with a typical unreinforced masonry wall specimen.

Seismic evaluation of existing RC frames with wide beams using an energy-based approach

  • Benavent-Climent, A.;Zahran, R.
    • Earthquakes and Structures
    • /
    • v.1 no.1
    • /
    • pp.93-108
    • /
    • 2010
  • This paper investigates the seismic performance of existing reinforced concrete frames with wide beams mainly designed for gravity loads, as typically found in the seismic-prone Mediterranean area before the introduction of modern codes. The seismic capacity is evaluated in terms of the overall amount of input energy that the frame can dissipate/absorb up to collapse. This approach provides a quantitative evaluation that can be useful for selecting and designing an appropriate retrofit strategy. Six prototype frames representative of past construction practices in the southern part of Spain are designed, and the corresponding non-linear numerical models are developed and calibrated with purposely conducted tests on wide beam-column subassemblages. The models are subjected to sixteen earthquake records until collapse by applying the incremental dynamic analysis method. It is found that the ultimate energy dissipation capacity at the story level is markedly low (about 1.36 times the product of the lateral yield strength and yield displacement of the story), giving values for the maximum amount of energy that the frame can dissipate which are from one fourth to half of that required in moderate-seismicity regions.

Seismic Performance Evaluation and a Comparative Study on the Design Wind and Earthquake Loads for Power Transmission Towers (송전철탑의 내진성능평가 및 설계 풍하중과 지진하중의 비교 연구)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Jang, Jung-bum;Yun, Kwan-hee;Kim, Tae-kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • In this study 24 power transmission towers were selected by considering various variables such as power transmission capacity, height and structural type to evaluate their seismic performance using the standard design response spectrum recently announced by the government. In addition, the stresses and sectional forces generated by the current design wind loads and revised seismic ones were compared to review the effects on the design of power transmission towers when the government-required seismic standards were raised. The results of seismic performance evaluation for the target power transmission towers showed that they had seismic capacity of 0.31~0.91g, and that they met the level of the earthquake-resistant special grade, which is the 2,400-year earthquake return periods and secured seismic safety. Further, the sectional forces caused by earthquakes in the towers were 33~82.5% of the ones due to wind loads, and it was also confirmed that the design wind loads were more dominant than design earthquake ones under the elevated seismic standards.

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • v.39 no.3
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.

Application of Capacity Design Methodology to RC Coupled Shear Wall (능력설계에 의한 RC 연결전단벽 구조의 내진설계)

  • Lee, Han-Seon;Jeong, Seong-Wook;Ko, Dong-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.295-298
    • /
    • 2005
  • Coupled shear wall(CSW) has been adopted as a lateral force resisting system in building frame structures. New Zealand code recommends the capacity design in designing the CSW. Capacity design based on using moment redistribution of member force may provide the economical benefit to designer. In this study, CSW's are designed by both capacity design and strength -based design. The design results and the seismic performance are compared by using nonlinear static analyses. The amount of reinforcement of shear wall and the section area of steel coupling beams by capacity design appear to be reduced by 19$\%$ and 17$\%$, respectively. Also CSW designed by capacity design shows good seismic performance at the ultimate state.

  • PDF

Strengthening method using externally-bonded steel frames for promoting the seismic performance of existing buildings (기존 건축물 내진성능 향상을 위한 철골 골조 외부부착 보강공법)

  • Mauk, Ji-Wook;Park, Young-Mi;Park, Ki-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.98-99
    • /
    • 2018
  • Seismic retrofitting technologies have been paid attention to structural engineers for rehabilitations of existing building structures vulnerable to seismic loading conditions. This paper introduces the traditional strengtheing method applying externally-bonded steel frames to column and beam elements, and compares with the improved scheme using the frames with additional energy dissipation systems. Throughout experimental studies, it was observed that the method can be effective for promoting the seismic performance of seismic force-resisting systems by guaranteeing strong column-weak beam mechanism. Compared to the traditional manner, it was found that the new scheme can be more efficient for confirming capacity design concept, while energy dissipation systems can provide additional damping effects corresponding to lateral deformation which occurs at seismic force-resisting systems exposed to seismic excitations.

  • PDF

Experimental Study on the Seismic Performance of Continuous Bridge Model with Seismic Load Transmitting Devices (지진력 분산장치를 설치한 다경간 연속교의 내진성능향상에 관한 실험연구)

  • 배민혁;김재관;김익현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.409-414
    • /
    • 2003
  • A multi-span bridge model that is fixed in longitudinal direction at a single pier can be very vulnerable to the earthquake ground motion in longitudinal direction. If the seismic load exceeds the capacity of the pier, it can be severely damaged. However, such incident can be prevented if piers of movable support share the seismic load as setting up seismic load transmitting device. This study is performed to investigate seismic performance of continuous bridge model with seismic load transmitting devices which is proposed newly. It is found that continuous bridge model system with device is more effective about displacement control and seismic performance.

  • PDF

Seismic performance evaluation of steel moment frames with self-centering energy-dissipating coupled wall panels

  • Lu Sui;Hanheng Wu;Menglong Tao;Zhichao Jia;Tianhua Zhou
    • Steel and Composite Structures
    • /
    • v.47 no.5
    • /
    • pp.663-677
    • /
    • 2023
  • The self-centering energy-dissipating coupled wall panels (SECWs) possess a dual capacity of resiliency and energy dissipation. Used in steel frames, the SECWs can localize the damage of structures and reduce residual drifts. Based on OpenSEES, the nonlinear models were established and validated by experimental results. The seismic design procedure of steel frame with SECW structures (SF-SECW) was proposed in accordance with four-level seismic fortification objectives. Nonlinear time-history response analyses were carried out to validate the reasonability of seismic design procedure for 6-story and 12-story structures. Results show that the inter-story drifts of designed structures are less than drift limits. According to incremental dynamic analyses (IDA), the fragility curves of mentioned-above structure models under different limit states were obtained. The results indicate that designed structures have good seismic performance and meet the seismic fortification objectives.

An approach of seismic design for sheet pile retaining wall based on capacity spectrum method

  • Qu, Honglue;Li, Ruifeng;Hu, Huanguo;Jia, Hongyu;Zhang, Jianjing
    • Geomechanics and Engineering
    • /
    • v.11 no.2
    • /
    • pp.309-323
    • /
    • 2016
  • As the forefront of structural design method, capacity spectrum method can be applied conveniently, and through this method, deformation demand of structure can be considered. However, there is no research for the seismic application in the structure of sheet pile retaining wall to report. Therefore, focusing on laterally loaded stabilizing sheet pile wall, which belongs to flexible cantilever retaining structure and meets the applying requirement of capacity spectrum method from seismic design of building structure, this paper studied an approach of seismic design of sheet pile wall based on capacity spectrum method. In the procedure, the interaction between soil and structure was simplified, and through Pushover analysis, seismic fortification standard was well associated with performance of retaining structure. In addition, by comparing the result of nonlinear time history analysis, it suggests that this approach is applicable.