• Title/Summary/Keyword: Sedimentation quantity

Search Result 40, Processing Time 0.033 seconds

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Settling Velocity of Suspended Material in Nakdong River (낙동강 수계에서 부유물질 침강속도)

  • Joe, Gyu-Soo;Seong, Jin-Uk;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1533-1540
    • /
    • 2011
  • This study was conducted to identify the sedimentation quantity and settling velocity, sediment fundamental data that an important position of water quality management of Seston, POC, PP and PN in Nakdong river basin using a sediment traps to collect suspended material pollutants. Nakdong river basin is that average sedimentation quantity of seston, POC, PP and PN were 124~1,125 g/$m^2$/d, 2,963~25,072, 26~347, 445~2,184 mg/$m^2$/d, respectively. Settling velocity of Seston, POC, PP and PN were 17.0, 35.5, 8.7, 2.4 m/d. It was appeared that various results according to the river flow, weather and other environmental factors. There was no significant correlation, each suspended material pollutants. Sedimentation rates are likely to be overestimated because the flow is not considered to resuspended materials. Therefore diversification through continued monitoring is needed to be analyzed.

Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path (사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안)

  • Kim, Jung-Soo;Song Ju-Il;Rim Chang-Soo;Yoon, Sei-Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.

An Experimental Study for Reduction of Sedimentation Deposit in Combining Junction Manholes (합류맨홀에서의 유사퇴적 저감을 위한 실험적 연구)

  • Kim, Jung-Soo;Kim, Kyoung-Beom;Yoon, Sei-Eui
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.8
    • /
    • pp.767-782
    • /
    • 2012
  • Accumulation of sediment within pipelines, manholes, and other components of urban sewer systems can have a bad influence on sewerage arrangements, such as the resistance of the passage of flows, the cause of urban flooding and the premature operation of combined sewer overflows, and the inevitable pollution of watercourses. Therefore, it is necessary to understand the movements and sedimentation of sediment loads in combining junction manholes by experiments. In this study, hydraulic experimental apparatus which can change the manhole shapes (square, circle) were installed to measure deposited sedimentation quantity. The quantity of deposited sediment loads was measured by different conditions, for instance, the inflow conditions of sediment (continuous and certain period), the amount of inflow sediment, and the variation of inflow pipe of sediment. The combining junction manhole that was set up a inclined benching have the considerable effect of reduction of sedimentation in manholes without apropos of the change of manhole shapes. Therefore, the improved manhole could be increased the drainage capacity of sewerage arrangements in urban sewer systems.

A study on analysis of influx path and ingredient of sedimentation substance and groundwater influx quantity in downtown tunnel (도심지터널에 유입된 지하수량 및 침전물의 성분분석 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.219-226
    • /
    • 2005
  • The result that analyze for 6 years a groundwater influx quantity of total 60 catch-pit established in subway line 5 appeared with $0.77m^3/min$. When comparing design approaches of the catch-pit with design approaches of the box structure $2m^3/min$ and the tunnel structure $3m^3/min$, it is found that it has a surplus. Red sedimentation substance contains large portion of Fe. The earth retaining structure of a tunnel and groundwater containing more portion of Fe than other area rue the major factor of this substance. In case of white sedimentation substance, the most frequently founded ingredient is CaO, which is occurred in case grouting injection materials for ground reinforcement is transmitted into a tunnel system by ground water. This substance is doesn't affect safety of a tunnel.

  • PDF

Estimation on the Design Capacities of Residuals Treatment Facilities by the Quantity of Dewatered Sludge Generated from Water Treatment Plants (정수장에서 발생된 탈수슬러지의 량에 의한 배출수처리시설용량에 대한 평가)

  • Moon, Yong-Taik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.715-723
    • /
    • 2004
  • The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS occurs under quiescent conditions in the primary clarifier, where suspended solids are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. The relative solid and liquid fractions of a slurry are most commonly described by the solids concentration, expressed as mg/L or percent solids. The purpose of the present investigation is to estimate a suitability on the design capacities of residuals treatment facilities by the quantity of dewatered sludge generated from water treatment plants.

Modern Sedimentary Environment of Jinhae Bay, SE Korea

  • Park, Soo-Chul;Lee, Kang-Wook
    • Journal of the korean society of oceanography
    • /
    • v.31 no.2
    • /
    • pp.43-54
    • /
    • 1996
  • Jinhae Bay, one of the largest tidal bays on the southern coast of Korea, is an area with thick accumulations of recent, fine-grained sediments, mainly supplied from the Nakdong River. The preponderance of silt and clay particles reflects the large quantity of sediments transported in suspension. Although the clay mineral assemblage is similar to that derived from the nearby Nakdong River, relatively high concentration (3-9%) of smectite suggests some local input of fine particles from several streams around the bay or some contribution from the offshore water that may be influenced by the Tsushima Current. The content of organic matters in sediments is as high as 12%, and their C/N ratios imply that they are comprised of mixtures derived from marine plankton and terrestrial plants. $^{210}Pb$ excess activity profiles of sediment cores yield an average sedimentation rate (a 100-year time scale) of about 2-5 mm/yr, which coincides well with the long-term sedimentation rate (a 1000-year time scale) estimated from the sediment isopach map. On the basis of sediment bulk density and sedimentation rate, an annual sink of mud in the bay is estimated approximately 1.0 ${\times}$ $10^{6}$ tons per year.

  • PDF

Assessment for Amount Increment of Dredged Soil using infiltrated consolidation method (침투압밀공법을 이용한 준설투기용량 산정)

  • Kwak, No-Kyung;Lee, Mu-Cheol;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1198-1209
    • /
    • 2009
  • In this study, an experimental research on the acceleration effect of dredged soil's self weight consolidation with seepage consolidation and PBD was conducted. The middle-sized consolidation equipment had been manufactured in order to investigate the acceleration of sedimentation and self-weight consolidation by PBD and a lower drainage. Seepage pressure was applied to the PBD installed in the center of the test equipment and a drainage by seepage pressure was allowed. The comparison between cases with and without PBD and seepage pressure reveals that the quantity of drained water and the amount of settlement was nearly 1.2 times to 3.68 times greater in the case with PBD and seepage. Early consolidation completion and the use of reclaimed site are expected due to the acceleration of settlement and increase of the quantity of reclamation if PBD is installed while being reclaiming using the result of the research.

  • PDF

Estimation of Water Quality Variation in Sewer Network using MOUSE TRAP Model (MOUSE TRAP 모델을 이용한 하수관거내 수질변화 예측)

  • Yang, Hae Jin;Jun, Hang Bae;Son, Dae Ik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.743-752
    • /
    • 2009
  • One of the major problems associated with operation of domestic sewer lines involves hydraulic problems such as insufficient conveyance capacity, exceeding maximum velocity, and deficiency of minimum velocity. It has also been pointed out that influent concentration lower than design concentration of pollutants, which is mainly caused by unidentified inflow and infiltration, degrades the operational efficiency of many sewage treatment plants (STPs). A computer-added analysis method supporting a coupled simulation of sewage quality and quantity is essentially required to evaluate the status of existing STPs and to improve their efficiency by a proper sewer rehabilitation work. In this study, dynamic water quality simulations were conducted using MOUSE TRAP to investigate the principal parameters that governs the changes of BOD, ${NH_4}^+$, and ${PO_4}^{3-}$3- concentrations within the sewer networks based on data acquired through on-site and laboratory measurements. The BOD, ${NH_4}^+$ and ${PO_4}^{3-}$3- concentrations estimated by MOUSE TRAP was lower than theoretical pollution loads because of sedimentation and decomposition in the sewer. The results revealed that sedimentation is a most important factor than other biological reactions in decreasing pollutant load in the sewers of C-city. The sensitivity analysis of parameters pertaining to water quality changes indicated that the effect of the BOD decay rate, the initial DO concentration, the half-saturation coefficient of dissolved BOD, and the initial sediment depth is marginal. However, the influence of settling rate and temperature is relatively high because sedimentation and precipitation, rather than biological degradation, are dominant processes that affect water quality in the study sewer systems.

A Study for Sedimentation in Reservoir -on district of Chin Young- (저수지의 퇴사에 관한 연구 -진양지구를 중심으로-)

  • 류시창;민병향
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3840-3847
    • /
    • 1975
  • With 30 excisting reservoirs in the Chin-Young area, the Sedimentation of the reservoirs has been calculated by comparing the present capacity with the original value, which revealed its reduced reservoir capacity. The reservoirs has a total drainage area of 3l4l ha, with a total capacity of 43.23 ha-m, and are short of water supply due to reduction of reservoir capacity, Annual sedimentation in the reservoir is relation to the drainage area, the mean of annual rainfall, and the slop of drainage area. The results of obtained from the investigation are summarized as follows: (1) A Sediment deposition rate is high, being about 7.03㎥/ha of drainage area, and resulting in the overage decrease of reservoir capacity by 16.1%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of tree. (2) An average unit storageof 116mm as the time of initial construction is decreased to 95.6mm at present. This phenomena cause a greater storage of irrigation water, sinceit was assumed that original storage quantity itself was already in short. (3) A sediment deposition rate as a relation to the capacity of unit drainge area is as follow: Qs=1.27(C/A)0.6 and standard deviation is 185.5㎥/$\textrm{km}^2$/year. (4) A sediment deposition rate as a relation to the mean of annual rainfall is as follow: Qs=21.9p10.5 and the standard deviation is 364.8㎥/$\textrm{km}^2$/year. (5) A sediment deposition rate as a relation to the mean slop of drainage area is follow: Qs=39.6S0.75 and the standard deviation is 190.2㎥/$\textrm{km}^2$/year (6) Asediment deposition rate as a relation to the drainage area, mean of rainfall, mean of slope of drainage area is: Log Qs=0.197+0.108LogA-6.72LogP+2.20LogS and the standard deviation is 92.4㎥/$\textrm{km}^2$/year

  • PDF